background image

 
Page 4 
 
 
CABINET DIMENSIONS, ELECTRICAL DATA, CABINET CAPACITIES 
 
        

 

     

   OUTSIDE   

 

           INSIDE 

Cabinet      

 

Length   Width   Height      Length     Width     Height 

 

 

 

 

 

 

               

HSD/SC-190Y            36.5         23.6      34.2 

31.26        18.35       24.5 

HSD/SC-220Y              40.6         23.6      34.2 

35.43        18.35       24.5   

HSD/SC-280Y              48.6         23.6      34.2 

43.62        18.35       24.5 

HSD/SC-320Y             54.4         23.6      34.2 

49.21        18.35       24.5 

 
HSD/SC-258                 42.5 

23.6       33.8 

  37.5         18.5         25.6 

HSD/SC-302                 45.7 

23.6       33.8 

  40.5         18.5         25.6 

HSD/SC-358   

 49.7 

26.7       34.2 

  44 

       20.6         26.6 

HSD/SC-408   

 53.7 

26.7       34.2 

  47.5         20.6         26.6 

HSD/SC-518    

 66.5 

26.7       34.2 

  60.5         20.6         26.6 

 
HSD/SC-132P 

31.5 

21.3       36.3 

  26.4          16.1         20.6 

 

HSD/SC-162P  

33.9 

21.3       36.3 

  28.7         16.1         20.6 

 

HSD/SC-192P 

38.8 

21.3       36.3          33.7          16.1         20.6 

HSD/SC-218P 

42.5  

21.3       36.3          37.4          16.1         20.6 

 
HBD/BC-142H 

28.9 

21.3       33.8 

  23.8          16.1         25.6 

 

HBD/BC-160H 

31.5 

21.3       33.8 

  26.4          16.1         25.6 

HBD/BC-180H 

33.9 

21.3       33.8          28.7          16.1         25.6 

HBD/BC-195H 

36.4 

21.3       33.8          31.3          16.1         25.6 

HBD/BC-215H 

38.8 

21.3       33.8          33.7          16.1         25.6 

HBD/BC-258H            42.5 

23.6       33.8          37.4          18.5         25.6 

HBD/BC-302H 

45.7 

23.6       33.8          40.6          18.5         25.6 

 
 
      

             ELECTRICAL                          CAPACITY 

           

   

           Breaker           Ship           Cubic    

 

              Volts        Size             Weight          Feet     

HSD/SC-190Y          115       15 amp             128       

   6.7 

 

HSD/SC-220Y          115       15 amp             137        

   7.8 

 

 

HSD/SC-280Y          115       15 amp             150                9.9       
HSD/SC-320Y          115       15 amp             159 

 11.3 

 

 

HSD/SC-258               115       15 amp             104 

   9.1 

 

HSD/SC-302               115       15 amp             110 

 10.7 

 

HSD/SC-358            115 

 

 15 amp             143 

 12.6 

  

HSD/SC-408            115 

 

 15 amp             145 

 14.4 

 

Summary of Contents for HBD/BC-142

Page 1: ...s Sliding Glass Top Solid Top Freezer Cooler Chests Curved Top Y Interior Step Flat Top Interior Step Flat Top P Flat Interior Solid Top H Interior Step Hussmann Corporation 12999 St Charles Rock Road...

Page 2: ...pacities 4 Refrigerant and Refrigerant Charges 5 Installation and Start Up Leveling Casters Baskets 6 Drain and Power Cord 7 Temperature Control and Defrosting 8 Cleaning Condenser 9 Cleaning Exterior...

Page 3: ...remove shipping crate and examine cabinet for concealed damage If damage is found contact the delivering carrier immediately and have his agent prepare an inspection report for the purpose of filing a...

Page 4: ...1 20 6 HSD SC 162P 33 9 21 3 36 3 28 7 16 1 20 6 HSD SC 192P 38 8 21 3 36 3 33 7 16 1 20 6 HSD SC 218P 42 5 21 3 36 3 37 4 16 1 20 6 HBD BC 142H 28 9 21 3 33 8 23 8 16 1 25 6 HBD BC 160H 31 5 21 3 33...

Page 5: ...nge from time to time R 134a HSD SC 190Y Curved Glass Top 5 64oz HSD SC 220Y Curved Glass Top 6 35oz HSD SC 280Y Curved Glass Top 7 05oz HSD SC 320Y Curved Glass Top 8 11oz HSD SC 258 Flat Top Int Ste...

Page 6: ...sters have a lock in place feature To activate the locking mechanism push down firmly on the plastic flange that protrudes from the caster To unlock the caster pull up on the flange The casters are of...

Page 7: ...product loss due to overloading or malfunction of other equipment on the same circuit Use a 15 amp time delay fuse The supply circuit must conform to National and local electrical codes A wiring diagr...

Page 8: ...refrigerator temperatures Due to the case design once an adjustment is made some time will lapse before the temperature inside the fixture reacts to the change DEFROSTING Disconnect Power Supply Befo...

Page 9: ...NTERIOR For cleaning the interior of the liner storage area a flush out drain has been provided on the case floor to assist in getting rid of any water in the bottom of the case Disconnect the electri...

Page 10: ...artment opening 7 Defective condenser fan motor 7 Replace High head pressure 1 Cabinet location too warm 1 Relocate cabinet remove air flow restriction 2 Defective condenser fan motor 2 Replace 3 Air...