P/N 3141959_C
5-7
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
FNGSC-A Self Contained Merchandisers
REPLACING SOLENOID VALVES
Unplug the power cords before servicing.
1 . Remove product and place in a refrigerated
area . Make sure the power is off to the
case .
2 . Make sure there is no voltage in the
refrigerator . Remove rear lower panel .
4 . Remove condensate pan screws and
disconnect heater wires .
5 . Take off the condensate pan and replace
heater .
6 . Reverse the process and make sure
everything is in place .
Parts may be ordered at Hussmann’s Performance
Parts e-store:
https://parts.hussmann.com/
Call toll free: 855-487-7778
or
Required Tools:
•
Screwdriver / Philips Tip
•
1/4
"
Allen Wrench
•
Copper Tubing Cutter
•
Blow Torch
FNGSC8A Shown
FNGSC8A Shown
FNGSC8A Shown