1-4
I
NSTALLATION
P/N 3141959_C
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
SERIAL PLATE LOCATION
The serial plate is located on the inside of the
merchandiser’s display area .
REFRIGERATION UNIT ACCESS
The lower front panel may be removed by
lifting the panel straight upward and over the
tabs on which it is hanging . For self contained
cases, two screws will have to be removed from
either end of the panel . Make sure all electrical
wiring is secured, and that there is no damage
to the unit from shipment or placement .
Confirm there are no refrigerant leaks during
startup of the case(s) .
The panel is installed
by reversing the above procedure . Ensure
merchandiser base is properly installed on case
to prevent air circulation problems .
SEALING MERCHANDISER TO FLOOR
If required by local sanitary codes, or if the
customer desires, merchandisers may be sealed
to the floor . Make sure lower front and rear
panels are still able to be removed to service the
condensing unit when sealing around the case .
NOTE:
Do not allow trim to cover any intake
or discharge grilles located in the lower front
panel . When the merchandiser is equipped
with levelers, sealing to the floor may not be
required . Merchandiser may be relocated to
another location so that floor can be cleaned .
REMOVE CENTRAL
AND SIDE SCREWS
Condensing Unit
Condensing Unit
Electrical Box
Both Sides
Fan
Fan
Condensing Unit
Electrical Box
both sides
Condensing Unit
Serial Plate
Remove Central
and Side Screws
(FNGSC8A) Shown