2-6
E
LECTRICAL
/ R
EFRIGERATION
P/N 3141959_C
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
REFRIGERATION SYSTEM LAYOUT
Product must be pre-frozen for low temp
applications . For medium temperature
applications products must be pre-chilled .
The evaporator is dual circuited . Circuit 1 is
the bottom section and Circuit 2 is the top
section . In Figure B, lefthand circuit is shown .
The flow is described as the following:
Cap tube is feeding the bottom section of the
coil . Once the refrigerant passes through the
evaporator, refrigerant goes out to the suction
line to the compressor .
The discharge line runs through the evaporation
pan to increase the water temperature, located
in the top level of the evaporation pan . At
the same time, refrigerant temperature drops,
increasing system capacity .
Machine Compartment Layout
Refrigeration Circuit #1 (left side)
Hot Gas Line
Hot Gas tee
Evap Inlet
Evap Outlet
AIR INTAKE
AIR EXHAUST
Condensing Unit (lefthand)
Controller
Electrical Box
Condensing Unit (righthand)
Solenoid Valves
Refrigeration Outlet
Drain
Elec Enclosure Box
Electrical
Outlets
Refrigeration
Outlet
Drain
(FNGSC8A shown)