IGIP-DBP, DBRP 01,03-0210

20

The MODEL NAME and SERIAL NUMBER is required in order to provide you
with the correct parts and information for your particular unit.

They can be found on a small metal plate on the unit.
Please note them below for future reference.

MODEL:

SERIAL NUMBER:

/Chino

Additional copies of this publication may be obtained by contacting:

Hussmann

®

 Chino

13770 Ramona Avenue • Chino, California 91710
(909) 628-8942 FAX
(909) 590-4910
(800) 395-9229

Service Record

Last service date:       By:

Summary of Contents for Chino DBP Series

Page 1: ...Chino DBP DBRP 01 03 ISLAND PRODUCE REV 0210 Installation Operation Manual DBP DBRP 01 03 ISLAND PRODUCE P N IGIP DBP DBRP 01 03 0210 INSTALLATION OPERATION GUIDE...

Page 2: ...ossible shortages of mate rial If a shortage should exist and is found to be the re sponsibility of Hussmann Chino notify Hussmann Chino If such a shortage involves the carrier notify the carrier imme...

Page 3: ...n Ref 6 24 16 26 1 8 DBRP 03 Shown with Optional Ref High Center Divider and Refrigerated Lighted Shelves Scale 3 8 30 Optional Ref High Center Divider and Ref Lighted Shelves Optional Base Display C...

Page 4: ...etach the walls from each other and remove from the skid Unbolt the case from the skid The fixture can now be lifted off the crate skid Lift only at base of stand EXTERIOR LOADING These models have no...

Page 5: ...e and outside rear mullion on both cases to be joined 5 Apply liberal bead of case joint sealant butyl to dotted area shown in Fig 2 1 of first case Apply heavy amount to cover entire shaded area DO N...

Page 6: ...e Store plumb ing system floor drains should be at least 14 off the center of the case to allow use of the P trap pipe section Never use two water seals in series in any one line Double P traps in ser...

Page 7: ...section of this guide The number of defrosts per day should never change The duration of the defrost cycle may be adjusted to meet conditions present at your location ACCESS TO TX VALVES DRAIN LINES...

Page 8: ...includes but not limited to Fans Heat ers Thermostats and Lights FIELD WIRING SERIAL PLATE AMPERAGE Field Wiring must be sized for component amperes printed on the serial plate Actual ampere draw may...

Page 9: ...horten the shelf life of the product 8 Cold coils remove heat and moisture from the case and deposit this as frost onto the coil Thus a defrost is required The only other moisture within the case is t...

Page 10: ...on loca tions Call for your closest location Ushio America Inc is located at 10550 Camden Drive Cypress CA 90630 T 5 BULBS Please note T 5 lights must be turned off and on after bulb replacement EVAPO...

Page 11: ...1 32 2 4 30 Out 11 2 208 19 0 100 Air 4 3 50 In 230 14 750 18 41 36 50 to Opt Forced 8 x 10 50 min 1 65 3 0 30 Out 11 2 208 19 0 100 Air 5 3 50 In 230 16 750 18 41 36 50 to Opt Forced 8 x 10 50 min 1...

Page 12: ...roller To Sensors S S MOTOR BALLAST B 232 B B MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR MOTOR 8 10 12 14 16 18 20 22 24 26 28 30 32 Evaporator Fan Motors Lighted Shelves Option...

Page 13: ...l Only dbrp 01k dgn MOTOR MOTOR MOTOR S S To Sensors Case Controller Computer Red 115 230V Black White 115V T Stat Liquid Solenoid Optional Optional Electronic TXV Evaporator Fan Motors MOTOR MOTOR B...

Page 14: ...Orange Field Connections between both sections S EEPR Valve Optional EEV TXV EEV TXV Optional 10 Case section 12 Case section Light switch in CAD Hussmann Corporation 13770 Ramona Avenue Chino Ca 917...

Page 15: ...ould perform a complete start up evaluation prior to the loading of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed with a refrig...

Page 16: ...ASHRAE Standard 72 and ASHRAE Standard 117 12 Are the shelf positions number and size other than recom mended by the manufacturer 13 Is there an improper application or control system 14 Is the evapor...

Page 17: ...ing handled in processing When a cut or tray of meat is not to be worked on immediately the procedure should call for returning it to refrigeration h Keep tools clean and sanitized Since mechanical eq...

Page 18: ...IGIP DBP DBRP 01 03 0210 18...

Page 19: ...nder this warranty shall be limited to a period not to exceed five years from date of factory shipment On Hussmann refrigeration systems an additional 4 year extended warranty for the motor compressor...

Page 20: ...r particular unit They can be found on a small metal plate on the unit Please note them below for future reference MODEL SERIAL NUMBER Chino Additional copies of thispublication may be obtained by con...