background image

 

 

 

Northern Airborne Technology Ltd. 

1925 Kirschner Road 

Kelowna, BC, Canada. 

V1Y 4N7 

Telephone (250) 763-2232 

Facsimile (250) 762-3374 

 
 

Issued on the authority of Northern Airborne Technology Ltd. 

 

Copyright 2009 

 
 

  Installation and Operation Manual 

 

RM01-001  

Remote Memory 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SM77 

 

ISSUE 1.01 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

 

The document reference is online, please check the correspondence between the online documentation and the printed version.

Summary of Contents for RM01-001

Page 1: ... 2232 Facsimile 250 762 3374 Issued on the authority of Northern Airborne Technology Ltd Copyright 2009 Installation and Operation Manual RM01 001 Remote Memory SM77 ISSUE 1 01 The document reference is online please check the correspondence between the online documentation and the printed version ...

Page 2: ...f this manual have been incorporated into the latest issue ISSUE REVISION RECORD Manuallssue Section Nurnber Revision Number 1 01 Section 1 Rev 1 01 1 00 Section 1 Rev 1 00 Section 2 Rev 1 00 Section 3 Rev 1 00 Installation and Operation Manual ENG FORM 820 0114 DOT Revision Description ETSO Changes Initial release Issue Date Sep 3 2009 Apr29 2009 Page ii CONFIDENTIAL AND PROPRIETARY TO NORTHERN A...

Page 3: ...onmental Specifications 1 2 1 4 4 Product Approval 1 3 2 Installation 2 1 Introduction 2 1 2 2 Unpacking and Inspection 2 1 2 2 1 Warranty 2 1 2 3 Continued Airworthiness 2 1 2 4 Installation Procedures 2 1 2 4 1 Warnings 2 1 2 4 2 Cautions 2 2 2 4 3 Cabling and Wiring 2 2 2 4 4 Mounting 2 2 2 4 5 Post Installation Checks 2 3 2 5 Adjustments and Connections 2 3 2 6 Accessories Required But Not Sup...

Page 4: ...The document reference is online please check the correspondence between the online documentation and the printed version ...

Page 5: ...S is a communications management system that distributes and controls all of the audio in an aircraft It manages the audio from all transceivers receivers and audio warning sources It enables the transmission of microphone audio to a selected transmitter and distributes all Inter Communication System ICS audio The RM01 is a remote mounted device that connects to the DACS AMU50 Audio Management Uni...

Page 6: ...and Finish Brushed aluminium conversion coated Connectors One 9 pin D sub male Jackpost locking hardware Installation SPI Cable 0 3 m 11 81 in maximum Installation Kit RM01 IKC Mounting Bulkhead Mount four 6 32 screws 1 4 3 Environmental Specifications The RM01 has been tested to the environmental conditions listed below Environmental categories for which TSO compliance has been demonstrated are l...

Page 7: ...8B Level C Refer to SM76 AMU50 001 Audio Management Unit Installation and Operation manual for further installation compliance details 1 4 4 2 EASA ETSO C50c When installed as part of the Northern Airborne Technology Ltd DACS EASA ETSO C50c RTCA DO 214 Class Ib RTCA DO 160E RTCA DO 178B level C Refer to SM76 AMU50 001 Audio Management Unit Installation and Operation manual for further installation...

Page 8: ...The document reference is online please check the correspondence between the online documentation and the printed version ...

Page 9: ...ion by an authorized NAT dealer to be free of defects in workmanship or performance This warranty covers all materials and labour but is exclusive of any transport to deliver the defective unit to and from NAT or its designated warranty repair center or any labour to remove or re install the defective unit in the aircraft Contact NAT for any questions regarding this warranty its applicability to y...

Page 10: ...elded wire applications use Tefzel MIL C 27500 shielded wire with solder sleeves for shield terminations to make the most compact and easily terminated interconnect Follow the connector map in Section 2 7 as required Allow 3 from the end of the shielded wiring to the shield termination to allow the connector hood to be easily installed Reference the interconnect drawing in Section 2 7 for shield t...

Page 11: ... 2 5 Adjustments and Connections The RM01 stores system configuration data for an audio control system such as the DACS When installed in the DACS the configuration data can be modified using the Device Configuration Software DevCs application Refer to the SM76 AMU50 001 Audio Management Unit Installation and Operation Manual and the DevCs Installation and Operation manual for information on conne...

Page 12: ...PE SERIAL No RM01 001 403 0 1 21 Remote Memory Interconnect 3000 and up RM01 001 405 0 1 00 Remote Memory Connector Map 3000 and up RM01 001 521 0 1 01 Remote Memory Environmental Qual Form 3000 and up RM01 001 922 0 1 10 Remote Memory Mechanical Installation 3000 and up Section 2 ends following the above documents The document reference is online please check the correspondence between the online...

Page 13: ...CE WITH AC43 13 1B CHANGE 1 PARAGRAPHS 11 76 THROUGH 11 78 WIRE TYPES SHOULD BE TO MIL W 22759 AS SPECIFIED IN AC43 13 1B CHANGE 1 PARAGRAPHS 11 85 11 86 AND LISTED IN TABLE 11 11 ALL SHIELDED WIRE CABLE SHOULD BE IN ACCORDANCE WITH MIL C 27500 L1 GROUNDED NOT MORE THAN 0 7 FT 0 2 M FROM UNIT SHIELDS SHOULD BE GROUNDED TO CONNECTOR BACK SHELL METAL TYPE ffi CABLING NOT MORE THAN 1 FT 0 3 M FROM UN...

Page 14: ...IRFRAME CONNECTOR CONFIDENTIAL AND PROPRIETARY TO NAT LTD DESIGNED MDO DRAWN MWS nat NORTHERN AIRBORNE TECHNOLOGY LTD DATE JUL 12 07 TITLE NAT REMOTE MEMORY CHECKED 249 NAT SIZE CAGE CODE 1 PART NO 1REV 1SHEET APPROVED 129 A 3AB01 RM01 001 1 00 1 1 FILE 405 0 DWG DWG TYPE CONNECTOR MAR 1DWG NO RM01 001 405 0 The document reference is online please check the correspondence between the online docume...

Page 15: ...Temperature Variation Humidity Operational Shocks and Crash Safety Operational Shocks Crash Safety Vibration 1Rev 1 01 ENG FORM 521 0102 DOT Section 4 0 4 5 1 4 5 1 4 5 2 4 5 3 4 5 3 4 5 4 4 5 5 4 6 1 4 6 2 4 6 3 5 0 6 0 7 0 7 2 2 7 3 2 Description of Conducted Tests Category A4 D1 55 c 45 c 40 c 85 c 70 c 70 c N A No forced air cooling 50 000 ft 15 240 m 8 000 ft to 50 000 ft 2 438 m to 15 240 m ...

Page 16: ...b requirement for equipment with digital circuits The system was tested to D0 160E subparagraph 16 6 1 1 b 3 Emergency Operating Voltage conditions The system was tested to D0 160E subparagraph 16 6 2 2 Low Voltage Conditions Voltage Spike 17 0 Category A Equipment receives conditioned input power from AMU50 xxx The equipment was tested configured as part of the DACS Audio Frequency Susceptibility...

Page 17: ...tegory X no test performed Electrostatic Discharge 25 0 Category X no test performed Fire Flammability 26 0 Category X no test performed Other Tests REMARKS D0 160E Sections 4 to 8 and 15 to 17 tests were conducted at Northern Airborne Technology Ltd NAT in Kelowna BC on RM01 001 D0 160E Sections 18 to 22 tests were conducted at CKC Laboratories in Bothell WA on RM01 001 Testing was conducted with...

Page 18: ...EL WAY CENTER OF GRAVITY 0 0 NOTES 1 DIMENSIONING AND TOLERANCING IN ACCORDANCE WITH ASME Y1 4 5M 1 994 CONFIDENTIAL AND PROPRIETARY TO NAT LTD TOLERANCES UNLESS DIMENSIONS DESIGNED MO STATED OTHERWISE IN INCHES DRAWN MWS nat NORTHERN AIRBORNE TECHNOLOGY LTD O X 0 030 THI RD ANGLE JUN 11 07 O XX 0 010 PROJECTION DATE TITLE REMOTE MEMORY O XXX 0 005 Et AT O XXXX 0 002 CHECKED NAT ANGLE 0 5 DEG 05 2...

Page 19: ...r Communication System ICS audio The RM01 is a remote mounted device that connects to the DACS AMU50 Audio Management Unit The RM01 stores the system s configuration and aural alert files Storing the system configuration and alert files in this unit enables the replacement of the AMU50 without the need of downloading a new configuration file The RM01 communicates with the AMU50 over a Serial Perip...

Page 20: ...The document reference is online please check the correspondence between the online documentation and the printed version ...

Reviews: