background image

4

 

Safe-NET software Version 9.03 or later

 

1 October 2009  —  P/N 0512887_A

 

ARV-570 & ARV-1230

ARV-570 & ARV-1230

ARV-570 

& ARV-1230

ARV-570 & ARV-1230

ARV-570 & ARV-1230

ARV-570 

& ARV-1230

 

PLUG IN

 

Put the Hussmann Beer Merchandiser on its

 

own dedicated electrical circuit with ground.

 

12AWG is the minimum size wire acceptable.

 

• The 

ARV-570

requires a dedicated 15 Amp

 

circuit with grounded wall receptacle 
(NEMA 5-15P)

 

• The 

ARV-1230 

double door Hussmann Beer

 

Merchandiser requires a dedicated 20 Amp 
circuit with a special wall receptacle 
(NEMA 5-20P).

 

• Do not use extension cords. Never use

 

adapters.

 

• If in doubt, call an electrician.

 

Electrical requirements for the merchandiser

 

are stated on the serial plate attached to the

 

unit.

 

If the power supply oscillates beyond the range

 

given in the preceding table, install a voltage 
regulator:  

Light Switch

 

Hussmann Beer Merchandiser light switches

 

are located on the top right side of the interior.

 

INSTALL SHELVES

 

ARV-570

– Four rows of flat shelves,

 

OR

Five rows of flat wire shelves,

 

OR

Four rows of gravity feed shelves 
with product guides.

 

ARV-1230

– Four rows of flat wire shelves,

 

OR

Five rows of flat wire shelves.

 

Metal shelf clips fit into slotted strips in the

 

interior on each side at the front and back of

 

the cooler. Each shelf requires four shelf clips. 

ARV-570 & ARV-1230

 

©2009 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.

 

U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

 

NEMA 5-15P

 

ARV-570

 

NEMA 5-20P

 

ARV-1230

 

ARV-570

ARV-1230

 

1500 VA

3000 VA

 

Nominal

 

Voltage

 

Minimum

 

Voltage

 

Maximum

 

Voltage

 

120

108

132

 

Bottom Shelf

 

Slotted Strips

 

Place Clips

 

Place Clips

 

Place Clips

 

on Both Sides

 

of Chamber

 

S

HELF

P

ART

N

UMBERS

 

ARV-570

 

Flat Shelf (2/pkg)

SH.

4968432

1

 

Gravity Feed Shelf (each)

SH.7960665

 

ARV-1230

 

Flat Shelf - Left (each)

SH.4978748

 

Flat Shelf - Right (each)

SH.4978751

 

Light switches

 

Summary of Contents for ARV-1230

Page 1: ...ARV 570 ARV 1230 Owner s Manual P N 0512887_A 1 October 2009 Beer Merchandiser P N0512887A...

Page 2: ...ach case carries a label identifying the type of application for which the case was certified ANSI NSF 7 Type II Display Refrigerator Freezer Beverage Cooler Intended for 80 F 55 RHAmbientApplication...

Page 3: ...XICO 1 800 522 1900 WWW HUSSMANN COM Hussmann Beer Merchandiser ARV 570 ARV 1230 ARV 570 ARV 1230 ARV 570 ARV 1230 ARV 570 ARV 1230 To reduce the risk of fire electrical shock or injury when using you...

Page 4: ...Or Damage When loss or damage is not apparent until after equipment is uncrated retain all packing mate rials and submit a written request to the carrier for inspection within 15 days UNCRATE Use the...

Page 5: ...s by turning the thumb screws clock wise Carefully lift the unit to insert shims as needed to prevent the chamber from rolling or tilting Thumbscrew locks are packed in an envelope inside the merchand...

Page 6: ...r Light Switch Hussmann Beer Merchandiser light switches are located on the top right side of the interior INSTALL SHELVES ARV 570 Four rows of flat shelves OR Five rows of flat wire shelves OR Four r...

Page 7: ...e product stop goes to the rear for flat shelves The ARV 1230 shelves have product stops toward the center of the merchandiser 4 Use the bracket numbering on each side to guide placement of shelves Sh...

Page 8: ...d 3A for ARV 570 and should not be used for anything other than a lighted sign requiring the stated Amperage or less The plug is protected by a separate fuse The fuse can be replaced with a like fuse...

Page 9: ...ows Safe Net 9 03 1 Version C570 Case Model OR C123 FOR TWO DOORS 75 2 temperature of air entering the evaporator 1 The Version will change dependent on current version installed 2 The temperature of...

Page 10: ...SELECT button EASy is displayed Press the DOWN button until you see CLOC Press SELECT and the MINUTES begin to flash With minutes flashing use the UP or DOWN button until the correct minutes are disp...

Page 11: ...g the defrost cycle Defrost is necessary because the Hussmann Beer Merchandiser operates at temperatures below freezing 26 F 3 3 C Defrosting is done automatically with Safe NET Defrost water drains t...

Page 12: ...the number of defrosts that occur in a 24 hour period beginning with the StAr first defrost parameter The maximum number of defrosts allowed in a 24 hour period is 8 The defrosts are spaced evenly acr...

Page 13: ...er closing for the night so that it can pull down to temperature overnight 3 Stock bottles upright only 4 Do not add warm product during selling hours The LED display shows the calculated actual beer...

Page 14: ...or acidic based cleaners on any interior surfaces A hose on display or interior lights or any other electrical connection Do First disconnect electrical power Remove the product and all loose debris...

Page 15: ...eaned at least once each month A dirty coil will slow product cooling significantly and can increase energy consumption by as much as 20 Remove screws on each side of the louvered front grille then li...

Page 16: ...sleeve 7 Reassemble in reverse order 8 Plug the unit in 9 Allow the unit to run for at least 30 minutes before stocking with fresh product 14 Safe NET software Version 9 03 or later 1 October 2009 P N...

Page 17: ...eeve 8 Reassemble in reverse order 9 Plug the unit in 10 Allow the unit to run for at least 30 min utes before stocking with fresh product 15 P N 0512887_A 1 October 2009 Safe NET software Version 9 0...

Page 18: ...e connector from each end 5 Remove from holding clips 6 Replace the lamp and reconnect connectors 7 Reassemble in reverse order 8 Plug the unit in 9 Allow the unit to run for at least 30 minutes befor...

Page 19: ......

Page 20: ...roduct Poor airflow around unit Reposition unit to provide space on all sides Evaporator blocked by ice Verify that door is sealing completely Heavy use in high humidity reset Safe NET controller to i...

Page 21: ......

Page 22: ...rrants all sealed multi glass assemblies If within the warranty period it can be proven to the satisfaction of Hussmann s warranty administration organization that there is impaired visibility through...

Page 23: ...CLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS AND HUSSMANN NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE OF ITS...

Page 24: ......

Reviews:

Related manuals for ARV-1230