background image

SAFETY FIRST!

Before installing, read and understand the
operating manual. Any damage caused by 
not following directions given in this manual 
is out-of-warranty.

Contact

To request technical assistance with your 
Hussmann Beer Merchandiser, or to place a
service call, please phone Hussmann’s C

ALL

C

ENTER

• U.S. or Canada 1-800-922-1919 •

Mexico 1-800-522-1900.  

LOCATION

Hussmann Beer Merchandisers are designed
for a protected environment, out of direct sun
or rain. Placing the unit near heat sources
(ovens, grills, etc.) or in direct sun will 
adversely affect performance. Unusual ambient
conditions can be handled by changing settings
in the Safe-NET

controller. Temperatures 

of 80°F (27°C) and less than 55% R.H. are
considered normal ambient conditions.

The merchandiser may not operate properly in
environments of extreme temperature and
humidity [above 90°F (32°C) and 65% relative
humidity]. Performance issues resulting from
poor local conditions are out-of-warranty.

The merchandiser must have a minimum 5-inch
(13 cm) ventilation space at the back, at the
top, on each side, and below the door in front.

1

P/N 0512887_A  —  1 October 2009

Safe-NET software Version 9.03 or later

ARV-570 & ARV-1230

©2009 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

Hussmann Beer Merchandiser

ARV-570 & ARV-1230

ARV-570 & ARV-1230

ARV-570 & ARV-1230

ARV-570 & ARV-1230

To reduce the risk of fire, electrical shock or
injury when using your Hussmann Beer
Merchandiser:

• Always use a dedicated circuit with the

Amperage stated on the unit.

• Plug into an outlet designed for the plug.
• Do not use an adapter.
• Do not overload the circuit.
• Disconnect power before servicing.
• Replace any damaged power cord.
• Never turn off by pulling on the power cord.
• Unit must have electrical ground at all times.
• Never connect the ground wire directly to the

neutral wire or connect to gas, water, 
telephone, drain pipe, lightning rod, etc.

• Do not damage the refrigeration system.
• Do not use any mechanical device or other

means to speed the defrost process, except
as recommended by the manufacturer.

• Unplug the Hussmann Beer Merchandiser

before cleaning.

• Do not store or use toxic or dangerous

chemical products inside the case.

• Do not use electrical devices in the

Hussmann Beer Merchandiser unless 
recommended by the manufacturer.

• Use two or more people to move a unit.
• Keep packing materials away from children.

CAUTION

!

We reserve the right to change or revise specifications and product design in
connection with any feature of our products. Such changes do not entitle the
buyer to corresponding changes, improvements, additions or replacements
for equipment previously sold or shipped.

5-inch (13 cm) Required Ventilation Minimum 

Summary of Contents for ARV-1230

Page 1: ...ARV 570 ARV 1230 Owner s Manual P N 0512887_A 1 October 2009 Beer Merchandiser P N0512887A...

Page 2: ...ach case carries a label identifying the type of application for which the case was certified ANSI NSF 7 Type II Display Refrigerator Freezer Beverage Cooler Intended for 80 F 55 RHAmbientApplication...

Page 3: ...XICO 1 800 522 1900 WWW HUSSMANN COM Hussmann Beer Merchandiser ARV 570 ARV 1230 ARV 570 ARV 1230 ARV 570 ARV 1230 ARV 570 ARV 1230 To reduce the risk of fire electrical shock or injury when using you...

Page 4: ...Or Damage When loss or damage is not apparent until after equipment is uncrated retain all packing mate rials and submit a written request to the carrier for inspection within 15 days UNCRATE Use the...

Page 5: ...s by turning the thumb screws clock wise Carefully lift the unit to insert shims as needed to prevent the chamber from rolling or tilting Thumbscrew locks are packed in an envelope inside the merchand...

Page 6: ...r Light Switch Hussmann Beer Merchandiser light switches are located on the top right side of the interior INSTALL SHELVES ARV 570 Four rows of flat shelves OR Five rows of flat wire shelves OR Four r...

Page 7: ...e product stop goes to the rear for flat shelves The ARV 1230 shelves have product stops toward the center of the merchandiser 4 Use the bracket numbering on each side to guide placement of shelves Sh...

Page 8: ...d 3A for ARV 570 and should not be used for anything other than a lighted sign requiring the stated Amperage or less The plug is protected by a separate fuse The fuse can be replaced with a like fuse...

Page 9: ...ows Safe Net 9 03 1 Version C570 Case Model OR C123 FOR TWO DOORS 75 2 temperature of air entering the evaporator 1 The Version will change dependent on current version installed 2 The temperature of...

Page 10: ...SELECT button EASy is displayed Press the DOWN button until you see CLOC Press SELECT and the MINUTES begin to flash With minutes flashing use the UP or DOWN button until the correct minutes are disp...

Page 11: ...g the defrost cycle Defrost is necessary because the Hussmann Beer Merchandiser operates at temperatures below freezing 26 F 3 3 C Defrosting is done automatically with Safe NET Defrost water drains t...

Page 12: ...the number of defrosts that occur in a 24 hour period beginning with the StAr first defrost parameter The maximum number of defrosts allowed in a 24 hour period is 8 The defrosts are spaced evenly acr...

Page 13: ...er closing for the night so that it can pull down to temperature overnight 3 Stock bottles upright only 4 Do not add warm product during selling hours The LED display shows the calculated actual beer...

Page 14: ...or acidic based cleaners on any interior surfaces A hose on display or interior lights or any other electrical connection Do First disconnect electrical power Remove the product and all loose debris...

Page 15: ...eaned at least once each month A dirty coil will slow product cooling significantly and can increase energy consumption by as much as 20 Remove screws on each side of the louvered front grille then li...

Page 16: ...sleeve 7 Reassemble in reverse order 8 Plug the unit in 9 Allow the unit to run for at least 30 minutes before stocking with fresh product 14 Safe NET software Version 9 03 or later 1 October 2009 P N...

Page 17: ...eeve 8 Reassemble in reverse order 9 Plug the unit in 10 Allow the unit to run for at least 30 min utes before stocking with fresh product 15 P N 0512887_A 1 October 2009 Safe NET software Version 9 0...

Page 18: ...e connector from each end 5 Remove from holding clips 6 Replace the lamp and reconnect connectors 7 Reassemble in reverse order 8 Plug the unit in 9 Allow the unit to run for at least 30 minutes befor...

Page 19: ......

Page 20: ...roduct Poor airflow around unit Reposition unit to provide space on all sides Evaporator blocked by ice Verify that door is sealing completely Heavy use in high humidity reset Safe NET controller to i...

Page 21: ......

Page 22: ...rrants all sealed multi glass assemblies If within the warranty period it can be proven to the satisfaction of Hussmann s warranty administration organization that there is impaired visibility through...

Page 23: ...CLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS AND HUSSMANN NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE OF ITS...