1-6
I
nstallatIon
P/N 0501930_G
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
Apply Gaskets as Follows:
Right End ONLY
1 . Apply the 1
5
/
8
-inch gasket around the top
of the merchandiser as shown . It must be at
the edge . Check to be sure that there are no
gaps between gasket and merchandiser .
2 . Apply the 1 inch (25 mm) gasket on the
metal merchandiser frame as shown across
the bottom . Check to be sure that there are
no gaps between merchandiser and gaskets .
3 . Apply 1
5
/
8
-inch gasket across the top,
from one end of the merchandiser to the
other, where the merchandiser meets the
cooler wall . Lap gasket if necessary — do not
butt ends . The lengthwise gasket must lap
the front-to-back gasket to fill any gap at the
cooler wall .
Apply Silicone Sealant to Right End ONLY
from the top gasket to the bottom gasket as
shown in the illustration .
IMPORTANT
• Do not stretch gasket,
especially around corners .
• Do not butt gaskets;
always overlap them as shown .
• Remove paper backing
after gasket has been applied .
•
Perimeter gasket required by
NSF.
• End caps required for rail light .
C
O
O
L
E
R
W
A
L
L
F irst G asket
1
in.
Gasket
(24 mm)
S econd
G asket
1
5
/
8
in.
(41 mm)
S ilicone
S ealant
Apply G as kets to
R IG HT E ND
Insert
Alignment
S crews
Insert
Alignment P ins
Insert
Alignment
Rod
Apply G asket Along Full Length
of Case at Cooler Wall
S
I
L
I
C
O
N
E
S
E
A
L
A
N
T
Remove
Nut Retainers
Remove
Nut Retainers