GENERAL SAFETY PRECA
UTIONS
8
–
English
Guar
d for the blade
This guard is fi
tted above the cutting blade and is
designed to prevent parts of the blade or cutting
fragments from being thrown towards the user.
Chec
king the blade guard
•
Check that the guard is complete and without any
cracks or deformations.
Gr
ound fault circuit interrupter
(K 3000 Wet)
Ground fault circuit interrupters are for protection in case
an electrical fault should occur.
The LED indicates that the ground fault circuit interrupter
is on and that the machine can be switched on. If the LED
is not on, push the RESET button (green).
Check the ground fault circuit interrupter
•
Connect the machine to the socket. Push the RESET
button (green) and the red LED lights up.
•
Start the machine.
•
Push the TEST button (blue).
•
The ground fault circuit interrupter should trip and the
machine switch off instantly. If not, contact your
dealer.
•
Reset with the RESET button (green).
!
WARNING! Always check that the guard
is correctly fitted before starting the
machine. Check that the cutting blade is
fitted correctly and does not show signs
of damage. A damaged cutting blade can
cause personal injury. See instructions
under the heading Assembly.