1. Pull out the Longopac bag (A) and attach a cable tie
(B) to close the new Longopac bag.
A
B
2. Shake down the dust in the used Longopac bag.
3. Attach a cable tie 10 cm/3.9 in. below the first cable
tie to close the used Longopac bag. Cut off the
Longopac bag between the cable ties.
4. If the remaining part of the Longopac bag cassette
is too small to prepare a new Longopac bag, install
a new Longopac bag cassette. Refer to
new Longopac dust bag on page 93
.
5. Obey local regulations for disposal of the full
Longopac bag.
Troubleshooting
Troubleshooting schedule
Issue
Cause
Solution
The motor does not start.
No power.
Plug in machine.
Make sure that the power
source work and that there is
power in the left side contac-
tors.
The cable is defective.
Replace the cable.
The power switch is defective.
Replace the power switch.
The product make a low sound
when it is on.
Phase error. Only two phases present.
Turn off the product and contact
a electrician.
Dust in the motor impellars.
Turn off the product and contact
a electrician.
The motor is defektive.
Turn off the product and contact
your service agent.
The product blows instead of
sucking.
The phase relay is defective.
Turn off the product and contact
a electrician. Switch L1 and L3
on the motor and do a test of
the suction.