EN
© 2022 HUSLOG
All rights reserved
Touchless thermometer
11
1.
Always abide by any kinds of prohibitions, regulations and warnings
conveyed by the staff of the entity where you wish to use the
device.
2.
Do not use the device near flammable fabrics.
3.
This device may only be used by adults.
4.
Children must not play with this device - it is not a toy.
5.
Keep the device, its packaging and accessories out of reach of
children and pets.
6.
The device should not be operated or stored in dusty environments.
7.
Unattended children must not clean or maintain the unit. Cleaning
and maintenance of the appliance must be carried out as described
in section
7. Cleaning and conservation
.
8.
Avoid exposing the device to very low or very high temperatures
(below 5°C / 41°F or above 40°C / 104°F during operation and
below -
20°C /
-
7.6°F or above 55°C / 131°F during storage and
transportation). Extreme temperatures can affect service life of the
device.
9.
The device should not be used in dusty conditions. Make sure that
animals do not have access to the product. Damaged product can
have cracks or broken parts with dangerous sharp edges. Do not
expose the device to sunlight and do not place it in close proximity
to heat-generating devices. Plastic parts may deform, which may
affect the operation of the device or cause it to break down
completely.
10.
Do not immerse the device in water or other liquids, as wetting will
harm the electronics and may damage the equipment.
11.
Do not use the unit if it has fallen to the ground or is visibly
damaged.
12.
The device is used to measure and control body temperature. It
should be used in front of the uncovered forehead at a distance of
about 1-3 cm. The device can also indicate the approximate surface
temperature of the object at which it is aimed from a distance of
approximately 1-3 cm.
13.
Taking a measurement is not equivalent to a professional diagnosis.
The diagnosis can only be made by a doctor or a trained and
authorized person. In case of bad results always contact a physician.
14.
You are not allowed to change the dosage of medicines by yourself,
without consulting your doctor, only on the basis of the
measurement.
15.
Make sure that the device is not exposed to magnetic field
interference, as this may affect the measurement results.
16.
Careful with small parts - choking hazard.
17.
Only qualified personnel or an authorized service centre may install
or repair this product. Repair of the device by an unqualified service
or by an unauthorised service centre, as well as unauthorised
modifications on your own, may damage the device and void the
warranty.
3. Technical Specification
3.1 Technical data
Touchless thermometer
Model
KF-HW-005
Method of measurement
Touchless
Distance of measurement
1
–
3 cm
Measuring range
32
–
43
º
C (body temp.)
Maximum permissible
measurement error
± 0.3 º
C if between 32
–
34.9
º
C
± 0.2 º
C if between 35
–
42
º
C
± 0.3 º
C if between 42.1
–
43
º
C
Accuracy of measurement
0.1
º
C
Working
humidity/Temperature
10
–
40
º
C /
≤
85%
Storing
humidity/Temperature
-20
–
55
º
C /
≤
93%
Working
atmospheric
pressure
70
–
106 kPa
Power supply
3 V
⎓
,
2 x AAA 1,5 V
⎓ battery
Display backlighting
High contrast backlight
Temperature scope
Celsius or Fahrenheit degree scale
Automatic power off
After about 30 seconds.
Software version
V455