FLO-EQUALIZER

®

 INSTALLATION INSTRUCTIONS

Model 004490 Conventional Flo-Equalizer

®

1.  Turn off dispenser and relieve line pressure.

2.  Install pipe nipple (if necessary) to achieve proper 

flow direction.

3.  Use thread sealant on male threads -- DO NOT 

use Teflon tape.

4.  Tighten approximately ½ turn past hand tight - do 

not overtighten.

5.  Confirm nozzle is properly installed, pressurize 

the system and check for leaks.

NOTE:  In the event of pressure differential in excess of 25 psi / 1.7 bar across 

the Flo-Equalizer

®

 or the presence of debris obstructing movement of 

internal components, the Flo-Equalizer

®

 output may exceed 10 gpm / 

37.9 Lpm.

SPOUT REPLACEMENT INSTRUCTIONS

Model 001471 Light Duty Diesel Spout Assembly,

      001473 Unleaded Spout Assembly

1. Remove spout lock nut and spout.

2. Remove and discard spout seal.

3. Place new spout seal in groove.

4.  Insert new spout into body making sure the vent 

tube is in the port.

5.  While holding the spout in proper alignment, 

tighten spout lock nut firmly, approximately 35 - 60 

lbf•ft / 47 - 81 N•m. Do not overtighten.

GUARD REPLACEMENT INSTRUCTIONS

EASY-ON MATE GUARD

Model 003795

1. Remove old guard from nozzle.

2.  Install new guard over spout and pull back.

POPD

®

 MATE GUARD

Model 007815

1. Turn off dispenser and relieve line pressure.

2. Remove waffle splash guard (if applicable).

3. Remove old nozzle guard.

4.  Install new POPD

®

 mate guard over spout and pull 

back.

5.  Install desired advertisement and clear cover 

(model 006628).

FLUTED HANDLE COVER

Model 003376

1. Remove old handle cover.

2. Snap new handle cover into place.

WAFFLE SPLASH GUARD

Model 001808

1. Remove old waffle splash guard.

2.  Install new waffle splash guard over spout lock nut.

POPD

®

 CLEAR COVER

Model 006628

1.  Trim advertisement to 3.75 in / 95.25 mm x 3.75 in 

/ 95.25 mm.

2.  Notch corners of advertisement approximately .375 

in / 9.5 mm x .375 in / 9.5 mm.

3.  Turn clear cover "inside out".

4.  Center advertisement on POPD

®

 guard, using 

the notched corners as guides, and fold over the 

edges.

5.  Lay clear cover over advertisement, making sure 

the advertisement stays centered, and turn it "right 

side out".

6.  Confirm the cover is securely in place.

Husky Corporation • 2325 Husky Way • Pacific, MO 63069 • Phone: (800) 325-3558 • Fax: (636) 825-7300 • www.husky.com 

Page 4                                                                      009216-15 10/2019

HOLD OPEN CLIP INSTALLATION / REMOVAL INSTRUCTIONS

Model 003593 Hold Open Clip Kit

 

INSTALLATION

1. Remove nozzle from hose and drain.

2.  Position latch spring under latch clip and hold 

them in place. The latch clip should straddle the 

mating holes in the trigger lever.

3.  Insert latch rivet through latch clip and lever, 

making sure latch spring is secured in position by 

the rivet.

4.  Install push nut on rivet - DO NOT hammer in 

place.

5.  Squeeze lever several times to check operation.

6. Verify clip and lever are parallel.

NOTE:  Field installation of the hold open clip is NOT UL approved because 

improper installation may cause the nozzle to fail.

 

REMOVAL

1. Remove nozzle from hose and drain.

2.  Place nozzle on a flat surface in safe location.

3.  Hold up on the latch clip to prevent rivet from 

rotating.

4.  Drill off the riveted end using a ¼" / 6.4 mm bit.

5. Do not remove latch plate.

NOTE: Nozzles can be ordered without clips.

ACCESSORIES

Model 000397 

Unleaded spout gauge

Summary of Contents for XS E159503

Page 1: ... Check remove after date Annually Check for electrical conductivity Lubricate main valve stem All drive aways maintenance and inspection activities must be logged using the serial number of the individual product Apply city state or federal testing regulations as appropriate ANY TEST INSPECTION FAILURE REQUIRES IMMEDIATE EQUIPMENT REPLACEMENT OR REMOVAL FROM SERVICE MADE IN THE USA Pressure Activa...

Page 2: ...expressly excluded Husky reserves the right to change or improve the design of any Husky fuel dispensing equipment without assuming any obligations to modify any fuel dispensing equipment previously manufactured Use of equipment is at individuals own risk Always abide and adhere to city state and federal regulations regarding use and installation of dispensing equipment Always follow the product m...

Page 3: ... TROUBLESHOOTING GUIDE GENERAL TECHNICAL DATA Husky Corporation 2325 Husky Way Pacific MO 63069 Phone 800 325 3558 Fax 636 825 7300 www husky com Page 3 009216 15 10 2019 1 Activate dispenser 2 Insert spout into fill pipe opening 3 Lower hose end of nozzle so the spout spring catches the inside of the fill pipe 4 Raise the lever and begin fueling 5 Nozzle will shut off automatically when the tank ...

Page 4: ... cover 2 Snap new handle cover into place WAFFLE SPLASH GUARD Model 001808 1 Remove old waffle splash guard 2 Install new waffle splash guard over spout lock nut POPD CLEAR COVER Model 006628 1 Trim advertisement to 3 75 in 95 25 mm x 3 75 in 95 25 mm 2 Notch corners of advertisement approximately 375 in 9 5 mm x 375 in 9 5 mm 3 Turn clear cover inside out 4 Center advertisement on POPD guard usin...

Reviews: