FLO-EQUALIZER
®
INSTALLATION INSTRUCTIONS
Model 004490 Conventional Flo-Equalizer
®
1. Turn off dispenser and relieve line pressure.
2. Install pipe nipple (if necessary) to achieve proper
flow direction.
3. Use thread sealant on male threads -- DO NOT
use Teflon tape.
4. Tighten approximately ½ turn past hand tight - do
not overtighten.
5. Confirm nozzle is properly installed, pressurize
the system and check for leaks.
NOTE: In the event of pressure differential in excess of 25 psi / 1.7 bar across
the Flo-Equalizer
®
or the presence of debris obstructing movement of
internal components, the Flo-Equalizer
®
output may exceed 10 gpm /
37.9 Lpm.
SPOUT REPLACEMENT INSTRUCTIONS
Model 001471 Light Duty Diesel Spout Assembly,
001473 Unleaded Spout Assembly
1. Remove spout lock nut and spout.
2. Remove and discard spout seal.
3. Place new spout seal in groove.
4. Insert new spout into body making sure the vent
tube is in the port.
5. While holding the spout in proper alignment,
tighten spout lock nut firmly, approximately 35 - 60
lbf•ft / 47 - 81 N•m. Do not overtighten.
GUARD REPLACEMENT INSTRUCTIONS
EASY-ON MATE GUARD
Model 003795
1. Remove old guard from nozzle.
2. Install new guard over spout and pull back.
POPD
®
MATE GUARD
Model 007815
1. Turn off dispenser and relieve line pressure.
2. Remove waffle splash guard (if applicable).
3. Remove old nozzle guard.
4. Install new POPD
®
mate guard over spout and pull
back.
5. Install desired advertisement and clear cover
(model 006628).
FLUTED HANDLE COVER
Model 003376
1. Remove old handle cover.
2. Snap new handle cover into place.
WAFFLE SPLASH GUARD
Model 001808
1. Remove old waffle splash guard.
2. Install new waffle splash guard over spout lock nut.
POPD
®
CLEAR COVER
Model 006628
1. Trim advertisement to 3.75 in / 95.25 mm x 3.75 in
/ 95.25 mm.
2. Notch corners of advertisement approximately .375
in / 9.5 mm x .375 in / 9.5 mm.
3. Turn clear cover "inside out".
4. Center advertisement on POPD
®
guard, using
the notched corners as guides, and fold over the
edges.
5. Lay clear cover over advertisement, making sure
the advertisement stays centered, and turn it "right
side out".
6. Confirm the cover is securely in place.
Husky Corporation • 2325 Husky Way • Pacific, MO 63069 • Phone: (800) 325-3558 • Fax: (636) 825-7300 • www.husky.com
Page 4 009216-15 10/2019
HOLD OPEN CLIP INSTALLATION / REMOVAL INSTRUCTIONS
Model 003593 Hold Open Clip Kit
INSTALLATION
1. Remove nozzle from hose and drain.
2. Position latch spring under latch clip and hold
them in place. The latch clip should straddle the
mating holes in the trigger lever.
3. Insert latch rivet through latch clip and lever,
making sure latch spring is secured in position by
the rivet.
4. Install push nut on rivet - DO NOT hammer in
place.
5. Squeeze lever several times to check operation.
6. Verify clip and lever are parallel.
NOTE: Field installation of the hold open clip is NOT UL approved because
improper installation may cause the nozzle to fail.
REMOVAL
1. Remove nozzle from hose and drain.
2. Place nozzle on a flat surface in safe location.
3. Hold up on the latch clip to prevent rivet from
rotating.
4. Drill off the riveted end using a ¼" / 6.4 mm bit.
5. Do not remove latch plate.
NOTE: Nozzles can be ordered without clips.
ACCESSORIES
Model 000397
Unleaded spout gauge