Husky HSK012HD User'S Manual & Warranty Information Download Page 9

7

WARNING:

• Always use protective eyewear when using this product: contact with battery acid

may cause blindness and/or severe burns.

• Keep out of children’s reach.

FIRST AID:
SKIN:

If battery acid comes in contact with skin, rinse immediately with running water,

then wash thoroughly with soap and water. If redness, pain or irritation occurs,

seek immediate medical attention.

EYES:

If battery acid comes in contact with eyes, flush eyes immediately - for minimum

of 15 minutes - seek immediate medical attention.

CHARGING/RECHARGING

For maximum battery life, we recommend the Husky

START-IT ELITE

®

Jump-Start

System be kept fully charged at all times. If the battery is allowed to remain in a dis-
charged state, battery life will be shortened. 

NOTE: 

Recharging battery after each use will prolong battery life; frequent 
discharges between recharges will reduce battery life.

Charge up to 48 hours to reach full charge.

IMPORTANT: 

MAKE SURE ALL SWITCHES ARE TURNED OFF DURING
RECHARGING.

120 Volt AC Charging

Charge unit for full 48 hours using AC method, prior to first use
Recharge unit fully after each use
1. Simply plug the AC plug of the AC/DC adapter/charger into any standard 120

volt AC wall outlet.

2. Plug the barrel connector attached to the AC adapter/charger into the small bar-

rel receptacle on the jump-starter that is marked recharge port.

3. When charging is completed and the FULL light is on, remove the AC/DC charg-

er plug and store in a safe place.

NOTE: 

The unit cannot be overcharged using the AC method. The Husky

START-IT

ELITE

®

Jump-Start System also comes with a DC/DC charging adapter for

recharging the unit from a 12 volt DC accessory outlet in a vehicle or boat.

WARNING: 

Do not recharge for more than 4-5 hours maximum using 12 volt DC
method

AC ADAPTER/CHARGER

HSK012HD MAN ENGL 090105  9/1/05  5:42 PM  Page 7

Summary of Contents for HSK012HD

Page 1: ...rranty period The customer is responsible for the shipping charges on all returned items after 30 days During the warranty period Husky Power Products will be respon sible for the return shipping charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage ...

Page 2: ...E E E E IIIIN N N NS S S ST T T TR R R RU U U UC C C CT T T TIIIIO O O ON N N NS S S S TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS PRODUCT PLEASE RETAIN FOR FUTURE REFERENCE HSK012HD 4140 S W 30th Ave Ft Lauderdale FL 33312 U S Toll Free 866 584 5504 Jump Start System 12...

Page 3: ...o keep all clamps cords clothing and body parts away from moving vehicle components 9 Do not wear vinyl clothing when jump starting a vehicle friction can cause dan gerous static electricity sparks Remove all jewelry or metal objects that could cause short circuits or react with battery acid 10 Always disconnect the negative Black jumper cable first followed by the pos itive Red jumper cable excep...

Page 4: ... to be corrected 9 Although this unit contains a non spillable battery it is recommended that unit be kept upright during storage use and recharging To avoid possible damage that may shorten the unit s working life protect it from direct sunlight direct heat and or moisture 10 Check unit periodically for wear and tear Replace worn or defective parts imme diately Contact Husky s Customer Service de...

Page 5: ...or etc Operate 12 volt DC fans inflators fluorescent worklights cellular phones can quick charge a cellular phone by using the phone s 12 volt DC adapter cord spotlights TVs portable radios cassette or CD players and more The Jump Start System has an easy to read series of LED Light Emitting Diode charge indicators that show when the unit is fully charged or the level of charge in the bat tery Cha...

Page 6: ... non spillable maintenance free heavy duty new high energy density 17 Amp hour sealed battery Safe to use transport and store Requires no maintenance other than recharging for optimum operation Automatic taper charge for AC recharge Molded high impact case is tough and durable Built in emergency worklight with for roadside repairs and use in remote loca tions without utility power CAUTION Use only...

Page 7: ... TERMINAL OR MOVING PART 6 Double check the polarity is correct then turn jump start power switch to ON posi tion 7 Start vehicle do not turn key for longer than 5 6 seconds 8 After vehicle starts turn jump start s power switch to OFF position Remove clamps disconnect the negative black jumper cable first followed by the positive red jumper cable and replace them in the clamp holders CAUTION If en...

Page 8: ...is system is NOT designed to be installed as a replacement for a vehicle battery 4 Vehicles that have on board computerized systems may be damaged if vehicle bat tery is jump started Before jump starting this type of vehicle read the vehicle owner s manual to confirm that external starting assistance is advised 5 Excessive engine cranking can damage the vehicle s starter motor If the engine fails ...

Page 9: ...charges between recharges will reduce battery life Charge up to 48 hours to reach full charge IMPORTANT MAKE SURE ALL SWITCHES ARE TURNED OFF DURING RECHARGING 120 Volt AC Charging Charge unit for full 48 hours using AC method prior to first use Recharge unit fully after each use 1 Simply plug the AC plug of the AC DC adapter charger into any standard 120 volt AC wall outlet 2 Plug the barrel conn...

Page 10: ...the appliance and operate as usual CAUTION DO NOT USE THIS UNIT TO OPERATE APPLIANCES THAT DRAW MORE THAN 5 AMPS DC EMERGENCY WORKLIGHT The area light is controlled by an On Off switch Make sure the area light is turned OFF when the unit is being recharged or stored REPLACEMENT PARTS For replacement parts bulbs batteries fuses etc contact Husky Customer Service toll free 800 916 7004 Battery Repla...

Page 11: ...AINST RISK OF FIRE REPLACE FUSE ONLY WITH SAME TYPE AND RATING T0 REPLACE FUSE 1 Remove plug from accessory receptacle Remove the gold cap by turnng coun terclockwise and lifting off 2 Remove center pin and spring Remove fuse 3 Replace fuse with same type and size fuse 8 amp 4 Replace center pin and spring inside plug 5 Replace gold cap by turning clockwise onto plug SPECIFICATIONS Model No HSK012...

Page 12: ...HSK012HD MAN ENGL 090105 9 1 05 5 42 PM Page 10 ...

Reviews: