Husky HSK012HD User'S Manual & Warranty Information Download Page 5

INTRODUCTION

Congratulations on selecting the Husky

®

START-IT ELITE

®

Jump-Start System. This com-

pact jump-starter is unique in the amount of energy it can supply for its size. The inter-
nal battery is a high-density sealed, lead-acid battery that stores and delivers ener-
gy comparable to full sized ordinary jump-starters. Please read this guide carefully
before use to ensure optimum performance and avoid damage to the unit or items
that you are using it with. 

The Husky

®

START-IT ELITE

®

Jump-Start System is a compact, durable and portable

jump-start system for vehicles and boats that have a standard 12 volt battery sys-
tem. This self-contained, rechargeable system will start most vehicles and boats
without the need for a host vehicle or 120 volt AC power supply. It can also be
used as a safe, portable source of 12 volt DC electric power in remote locations
and/or emergency situations. It is ideal for use with Husky 12 volt DC cordless,
portable, rechargeable products.

Use the Husky

START-IT ELITE

®

Jump-Start System to:

Jump start any engine system with a standard 12 volt DC battery:

boat; truck; car; air-

plane; RV; personal watercraft; snowmobile; garden tractor; gasoline engine
generator, etc.

Operate:

12 volt DC fans, inflators, fluorescent worklights, cellular phones (can

quick-charge a cellular phone by using the phone’s 12 volt DC adapter cord),
spotlights, TVs, portable radios, cassette or CD players, and more.

The Jump-Start System has an easy-to-read series of LED (Light Emitting Diode) charge
indicators that show when the unit is fully charged, or the level of charge in the bat-
tery. Charge level can be viewed when the charge status push button is pressed. A
12 volt DC power accessory socket is provided for use with appliances that can oper-
ate from a vehicle 12 volt DC accessory outlet. This allows maximum portability and
utility when the Jump-Start System is used in remote locations.

The Jump-Start System can be recharged from any standard 120 volt AC power
source using the supplied AC Recharge Adapter. The adapter barrel connector
attaches to the Recharge Port on the top panel of the jump-starter.  A built-in 12 volt
appliance socket and the appropriate DC/DC charging/adapter cord is used to
recharge the battery from another 12 volt DC source. When pressed, the CHARGE
STATUS button will show the battery power level status (from Low to Full). The green
LED full indicator illuminates when the unit is fully recharged and charging can be 
discontinued. An ON/OFF switch operates the built-in work/emergency light.

3

HSK012HD MAN ENGL 090105  9/1/05  5:42 PM  Page 3

Summary of Contents for HSK012HD

Page 1: ...rranty period The customer is responsible for the shipping charges on all returned items after 30 days During the warranty period Husky Power Products will be respon sible for the return shipping charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage ...

Page 2: ...E E E E IIIIN N N NS S S ST T T TR R R RU U U UC C C CT T T TIIIIO O O ON N N NS S S S TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS PRODUCT PLEASE RETAIN FOR FUTURE REFERENCE HSK012HD 4140 S W 30th Ave Ft Lauderdale FL 33312 U S Toll Free 866 584 5504 Jump Start System 12...

Page 3: ...o keep all clamps cords clothing and body parts away from moving vehicle components 9 Do not wear vinyl clothing when jump starting a vehicle friction can cause dan gerous static electricity sparks Remove all jewelry or metal objects that could cause short circuits or react with battery acid 10 Always disconnect the negative Black jumper cable first followed by the pos itive Red jumper cable excep...

Page 4: ... to be corrected 9 Although this unit contains a non spillable battery it is recommended that unit be kept upright during storage use and recharging To avoid possible damage that may shorten the unit s working life protect it from direct sunlight direct heat and or moisture 10 Check unit periodically for wear and tear Replace worn or defective parts imme diately Contact Husky s Customer Service de...

Page 5: ...or etc Operate 12 volt DC fans inflators fluorescent worklights cellular phones can quick charge a cellular phone by using the phone s 12 volt DC adapter cord spotlights TVs portable radios cassette or CD players and more The Jump Start System has an easy to read series of LED Light Emitting Diode charge indicators that show when the unit is fully charged or the level of charge in the bat tery Cha...

Page 6: ... non spillable maintenance free heavy duty new high energy density 17 Amp hour sealed battery Safe to use transport and store Requires no maintenance other than recharging for optimum operation Automatic taper charge for AC recharge Molded high impact case is tough and durable Built in emergency worklight with for roadside repairs and use in remote loca tions without utility power CAUTION Use only...

Page 7: ... TERMINAL OR MOVING PART 6 Double check the polarity is correct then turn jump start power switch to ON posi tion 7 Start vehicle do not turn key for longer than 5 6 seconds 8 After vehicle starts turn jump start s power switch to OFF position Remove clamps disconnect the negative black jumper cable first followed by the positive red jumper cable and replace them in the clamp holders CAUTION If en...

Page 8: ...is system is NOT designed to be installed as a replacement for a vehicle battery 4 Vehicles that have on board computerized systems may be damaged if vehicle bat tery is jump started Before jump starting this type of vehicle read the vehicle owner s manual to confirm that external starting assistance is advised 5 Excessive engine cranking can damage the vehicle s starter motor If the engine fails ...

Page 9: ...charges between recharges will reduce battery life Charge up to 48 hours to reach full charge IMPORTANT MAKE SURE ALL SWITCHES ARE TURNED OFF DURING RECHARGING 120 Volt AC Charging Charge unit for full 48 hours using AC method prior to first use Recharge unit fully after each use 1 Simply plug the AC plug of the AC DC adapter charger into any standard 120 volt AC wall outlet 2 Plug the barrel conn...

Page 10: ...the appliance and operate as usual CAUTION DO NOT USE THIS UNIT TO OPERATE APPLIANCES THAT DRAW MORE THAN 5 AMPS DC EMERGENCY WORKLIGHT The area light is controlled by an On Off switch Make sure the area light is turned OFF when the unit is being recharged or stored REPLACEMENT PARTS For replacement parts bulbs batteries fuses etc contact Husky Customer Service toll free 800 916 7004 Battery Repla...

Page 11: ...AINST RISK OF FIRE REPLACE FUSE ONLY WITH SAME TYPE AND RATING T0 REPLACE FUSE 1 Remove plug from accessory receptacle Remove the gold cap by turnng coun terclockwise and lifting off 2 Remove center pin and spring Remove fuse 3 Replace fuse with same type and size fuse 8 amp 4 Replace center pin and spring inside plug 5 Replace gold cap by turning clockwise onto plug SPECIFICATIONS Model No HSK012...

Page 12: ...HSK012HD MAN ENGL 090105 9 1 05 5 42 PM Page 10 ...