17
English
6.1
CONNECTIONS
Connections on pressure washer hoses, gun and spray
wand should be cleaned regularly and lubricated with
light oil or non-water soluble grease to prevent leakage
and damage to the o-rings.
6.2 NOZZLE
Clogging of the nozzle causes the pump pressure to be
too high and cleaning is immediately required.
1. Clear the nozzle by forcing a stiff wire through
center hole.
2. Backflush the nozzle with water.
3. Reconnect the nozzle to the wand.
6.0 MAINTENANCE
6.3
LUBRICATION
The pressure washer is designed with a permanent
lubrication system. Conventional oil check and oil
changes are not necessary.
NOTE:
IN CASE OF OIL LEAKAGE, CONTACT THE
CUSTOMER SERVICE DEPARTMENT CONCERNING
REPAIR. A SMALL AMOUNT OF OIL LEAKAGE IS
NORMAL. www.huskypowerwasher.com.
6.4 WATER
SCREEN
The pressure washer is equipped with a water inlet
screen filter to protect the pump.
CAUTION:
If the screen is not kept clean,
the flow of water to the pressure washer
will be restricted and the pump may be
damaged.
To clean inner water screen, remove the inlet nipple
and remove the filter screen from the inlet.
Backflush screen to clean.
Replace screen and inlet nipple immediately to pre-
vent any foreign matter from entering the pump.
CAUTION:
Do not damage the screen
while removing or cleaning. Any foreign
particles entering the pump may damage
the pump.
6.5 COOLING
SYSTEM
The air vents, located in and around the pressure
washer, must be kept clean and free of any obstruc-
tions to ensure proper air cooling of the motor during
operation.
WARNING:
Prevent water from pene-
trating the vents of the pressure washer
to minimize the risk of damage to the
machine and to reduce the risk of shock
to the operator.
CAUTION
CAUTION
WARNING
7.0 SERVICING A DOUBLE-
INSULATED
APPLIANCE
In a double-insulated product, two systems
of insulation are provided instead of
grounding. No grounding means is pro-
vided on a double-insulated product, nor
should a means for grounding be added
to the pressure washer. Servicing a double-insulated
product requires extreme care and knowledge of the
system, and should be done only by qualified service
personnel.
Replacement parts for a double-insulated product
must be identical to the parts they replace. A double-
insulated product is marked with the words “DOUBLE-
INSULATION” or “DOUBLE-INSULATED”. The symbol
above may also be marked on the product.
Summary of Contents for HD1500
Page 4: ...4 English Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 ...
Page 6: ...6 English PARTS DRAWING Fig 8 ...
Page 15: ...15 English Fig 22 Fig 23 Fig 24 Fig 25 Fig 26 ...
Page 26: ...26 Español Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 ...
Page 28: ...28 Español DISEÑO PIEZAS Fig 8 ...
Page 37: ...37 Español Fig 22 Fig 23 Fig 24 Fig 25 Fig 26 ...
Page 48: ...48 Français Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 ...
Page 50: ...50 Français ILLUSTRATION DES PIÈCES Fig 8 ...
Page 59: ...59 Français Fig 22 Fig 23 Fig 24 Fig 25 Fig 26 ...