24
OPERATION
SPECIFIC SAFETY RULES
a) If not used correctly and without suitable mainte-
nance, the nailer can cause serious injury.
b)
Always wear goggles and ear plugs when using the tool.
c) Handle the nailer holding it firmly by the grip only.
d) Always disconnect the tool from the air supply
when unattended, performing any maintenance or
repair, clearing a jam, or moving the tool to a new
location.
Do not load the tool with nails when either the
trigger is depressed or the protection of no-mar tip (Fig. 9 -
F) is engaged. The tool could eject a nail causing death or
serious personal injury.
e)
Always fit tool with a fitting or hose coupling on or near
the tool in such a manner that all compressed air in the
tool is discharged at the time the fitting or hose coupling is
disconnected. Do not use a check valve or any other fitting
which allows air to remain in the tool. Death or serious
personal injury could occur.
f) Never place hands or any other body parts in the nail
discharge area of the tool.
The tool might eject a nail and
could result in death or serious personal injury.
g) Do not touch the trigger unless driving nails.
Never
attach air line to tool or carry tool while touching the
trigger. The tool could eject a nail which will result in death
or serious personal injury.
h) Always assume the tool contains nails.
Respect
the tool as a working implement; no horseplay. Always
keep others at a safe distance from the work area in case
of accidental discharge of nails. Do not point the tool
toward yourself or anyone whether it contains nails or not.
Accidental triggering of the tool could result in death or
serious personal injury.
i) Do not nail on top of another nail.
This is able to
cause the nail to be deflected and hit someone, or cause
the tool to react and result in a risk of injury to persons.
j) Do not drop or throw the tool.
Dropping or throwing
the tool can result in damage that will make the tool
unusable or unsafe. If the tool has been dropped or
thrown, examine the tool closely for bent, cracked or
broken parts and air leaks. STOP and repair before using
or serious injury could occur.
k) Always check that the protection of no-mar tip (F)
is operating properly.
A nail could accidentally be driven
if the protection of no-mar tip (F) is not working properly.
Personal injury may occur.
l) Disconnect air supply and release tension from the
trigger before attempting to clear jams because nails
can be ejected from the front of the tool.
Personal injury
may occur.
m) Never use the nailer against metal or masonry
objects.
n) Never exceed the maximum operating pressure
indicated for this accessory.
o) Avoid long extended periods of work with the tool.
Stop using the tool if you feel pain in hands or arms.
p)
Avoid using the tool when the magazine is empty
.
Accelerated wear on the tool may occur.
q)
Clean and check all air supply hoses and fittings
before connecting the tool to air supply
. Replace any
damaged or worn hoses or fittings. Tool performance or
durability may be reduced.
OPERATING INSTRUCTION
Technical data
Model No.: 9045701
Max. Operating Pressure: ..................................... 120 PSI
Operating Pressure Range: ............................. 70-115 PSI
Air inlet: ............................................................... 1/4” NPT
Magazine Capacity: .............................................. 50 nails
Nail Type: ....................................... 20-22° full round head
...................................................... (plastic ribbon collation)
Nail Lengths: .................................. 2” - 3-½” (50 - 90 mm)
Nail Size: .............................0.113”-0.131” (2.87-3.33 mm)
...................................... Head: 0.268-0.28” (6.8-7.1 mm)
Tool Length: ...........................................................20.079”
Tool Height: ..............................................................14.37”
Tool Width: .................................................................5.55”
Tool Weight (without fastener): ............................. 9.24 lbs
Preliminary checks
1) The air compressor must be able to maintain a
minimum of 70 PSI when the tool is being used. An
inadequate air supply can cause a loss of power and
inconsistent driving.
2) An oiler can be used to provide oil circulation through
the tool. A filter can be used to remove liquid and solid
impurities which can rust or “gum up” internal parts or
the tool.
3) Use 3/8” (10 mm) air hoses with a minimum working
pressure of 150 PSI. Use 1/2” (13 mm) air hoses for
50’run or longer. For better performance. Install a quick
plug with an inside diameter of 0.315” (8 mm) on the
tool and a quick coupler on the air hose.
4) Use a pressure regulator on the compressor. With an
operating pressure of 0-120 PSI. A pressure regulator
is required to control the operating pressure of the tool
between 70 and 115 PSI.
WARNING:
Read and follow all safety rules and operating
instructions in this manual and on warning label of tool
before using this tool. Keep this manual with the tool.
WARNING:
Clean and inspect tool daily. Carefully check for proper
operation of trigger and safety mechanism. Do not
use the tool unless both the trigger and the safety
mechanism are functional, or if the tool is leaking air or
needs any other repair.
Summary of Contents for H1504FK-R
Page 6: ...6...
Page 35: ...6...
Page 37: ...8 UNCA USE UN ADAPTADOR EL CTRICO CON ESTA CLAVIJA DE CONEXI N A TIERRA...