background image

5

HUSKYTOOLS.COM 

Please contact 1-888-43-HUSKY for further assistance.

pts-205109-051012,

 pts-2053019-053012,

 pts-206067-060612

 

WARNING: Risk of electrical 

shock. Improper electrical 

grounding can result in 

electrical shock.  The wiring 

should be done by a qualified 

electrician.

 

WARNING: Risk of electrical 

shock. Electrical wiring must 

be located away from hot 

surfaces such as manifold 

assembly, compressor outlet 

tubes, heads, or cylinders.

 

 

CAUTION:

 Improper electrical 

installation of this product may 

void its warranty and your fire 

insurance. Have circuit wiring 

performed by qualified personnel 

such as a licensed electrician 

who is familiar with the current 

national electrical code and any 

prevailing local electrical codes.

A qualified electrician needs to knows the 

following before wiring:

Safety Information (continued)

1.  The amperage rating of the electrical 

box should be adequate. Refer to the 

Specifications

 for this information.

2.  The supply line should have the same 

electrical characteristics (voltage, cycle, 

phase) as the motor. Refer to the motor 

nameplate, on side of motor, for this 

information. 

 

 

NOTICE:

 

The wiring used 

must be rated for the motor 

nameplate voltage, plus or minus 

10%.  Refer to local codes for 

recommended wire sizes, correct 

wire size, and maximum wire 

run; undersize wire causes high 

amp draw and overheating to the 

motor.

ELECTRICAL SAFETY  
(GROUNDING INSTRUCTIONS)

This product should be connected to a 

metallic, permanent wiring system, or an 

equipment-grounding terminal or lead on 

the product.

Air Distribution System

 

WARNING: Risk of bursting. 

Plastic or PVC pipe is not 

designed for use with 

compressed air. Regardless of 

its indicated pressure rating, 

plastic pipe can burst from air 

pressure. Use only metal pipe 

for air distribution lines.

Figure 1 represents a typical air distribution 

system. The following are tips to remember 

when setting up the air compressor’s air 

distribution system. 

 

 

NOTICE: 

Compressed air from 

oil lube air compressors will 

contain wa ter condensation 

and oil mist. Several drains, 

traps and filters will be needed 

to supply air without water 

(including aerosols) or oil to 

spray equipment, air tools and 

accessories requiring filtered 

air. Always read the in struc tions 

for the air tools and accessories 

being used.

• 

Use pipe that is the same size as the air 

tank outlet. Piping that is too small will 

restrict the flow of air. 

Summary of Contents for C601H

Page 1: ...ST Monday Friday 1 888 43 HUSKY HUSKYTOOLS COM THANK YOU We appreciate the trust and confidence you have placed in Husky through the purchase of this 60 gallon stationary air compressor We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Husky ...

Page 2: ...ON Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury NOTICE Indicates a practice not related to personal injury which if not avoided may result in property damage WORK AREA SAFETY 1 Keep your work area clean and well lit Ensure floors are not slippery from wax or dust 2 Do not operate power tools in explosive atmospheres such as in the presence...

Page 3: ...s Loose clothes jewelry or long hair can be caught in moving parts 4 Keep proper footing and balance at all times Proper footing and balance enables better control of the tool in unexpected situations 5 Do not use on a ladder or unstable support 6 Never touch any exposed metal parts on compressor during or immediately after operation Compressor will remain hot for several minutes after operation D...

Page 4: ... toxic fumes A respirator may be necessary in dusty environments or when spraying paint ELECTRICAL SAFETY 1 Avoid body contact with grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is grounded 2 Do not expose power tools to rain or wet conditions Water entering a power tool will increase the risk of electric shock 3 Replac...

Page 5: ...r this information NOTICE The wiring used must be rated for the motor nameplate voltage plus or minus 10 Refer to local codes for recommended wire sizes correct wire size and maximum wire run undersize wire causes high amp draw and overheating to the motor ELECTRICAL SAFETY GROUNDING INSTRUCTIONS This product should be connected to a metallic permanent wiring system or an equipment grounding termi...

Page 6: ...ual air driven tools DO NOT install lubricators between the tank and any spray equipment air tool or accessory requiring oil free filtered air Drain all traps filters and dirt legs daily AIR FLOW AIR FLOW FEEDER LINES SLOPE WITH AIR FLOW DRAIN LEGS MAIN DISTRIBUTION AIR LINES Slope pipe in dir w W bottom of pipe to drain legs preventing it f rom entering feeder lines AIR USAGE LINES FILTER MOISTUR...

Page 7: ...ess for a particular purpose are disclaimed Any implied warranties including warranties of merchantability or fitness for a particular purpose that cannot be disclaimed under state law are limited to two years from the date of purchase Husky is not responsible for direct indirect incidental special or consequential damages If this air compressor is used for commercial purposes the warranty will ap...

Page 8: ...ring NOTE Hardware not shown to actual size BB CC DD Part Description Quantity BB Concrete Anchors 4 CC 3 8 Lag Screw to fit concrete anchors 4 DD Shims as needed Package Contents HARDWARE INCLUDED NOTE Hardware not shown to actual size AA Part Description Quantity AA 5 8 Flatwasher 4 ...

Page 9: ... starts the motor when the air tank pressure drops below the factory set cut in pressure It stops the motor when the air tank pressure reaches the factory set cut out pressure C Safety Valve If the pressure switch does not shut off the air compressor at its cut out pressure setting the safety valve will protect against high pressure by popping out at its factory set pressure slightly higher than t...

Page 10: ...sure I Motor Overload Reset This motor has a manual thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting To restart 1 Place the Auto Off switch in the Off position 2 Allow the motor to cool 3 Depress the red reset button on the motor 4 Place the Auto Off switch in the Auto postion to...

Page 11: ...r instructions 3 Recheck all wiring Make sure wires are secure at all terminals connections Make sure all contacts move freely and are not obstructed 4 Open the drain valve F fully to permit air to escape and prevent air pressure build up in the air tank during the break in period Assembly continued 4 Line up holes in surface with holes in air compressor feet J 5 Place the washers AA supplied betw...

Page 12: ...ntain oil and rust which can cause stains NOTICE All compressed air systems generate condensate that accumulates in any drain point e g tanks filter aftercoolers dryers This condensate contains lubricating oil and or substances which may be regulated and must be disposed of in accordance with local state and federal laws and regulations NOTICE If drain valve is plugged release all air pressure The...

Page 13: ...ressure rating for air tools and accessories The regulator outlet pressure must never exceed the maximum pressure rating 1 Place Auto Off switch A Figure 5 to Off 2 Close the air discharge outlet 3 Visually inspect air lines and fittings for leaks 4 Check safety valve See Checking the Safety Valve paragraph CAUTION Risk of unsafe operation Compressed air from the unit may contain wa ter condensati...

Page 14: ...tic parts Most plastics are susceptible to damage from various types of commercial solvents and may be damaged by their use Use clean cloths to remove dirt dust oil grease etc Operation continued WARNING Risk of bursting If any unusual noise or vibration is noticed stop the air compressor immediately and have it checked by a trained service technician NOTICE When using regulator and other accessor...

Page 15: ...ing the oil fill cap or oil drain plug CAUTION Overfilling with oil will cause premature air compressor failure Do not overfill 1 Remove the oil fill plug L 2 Remove the oil drain plug M and drain oil into a suitable container 3 Replace the oil drain plug M and tighten securely 4 Slowly add compressor oil until it reaches the middle of the sight glass N NOTE When filling the crankcase the oil flow...

Page 16: ...e the belt and replace with a new one 6 See the Adjust Belt Tension before tightening motor mounting screws Maintenance continued 5 Adjusting Belt Tension Figure 7 1 Slide motor into original position line the motor up with the mark made earlier on saddle 2 Tighten two outside motor mounting screws enough to hold the motor in place for checking pulley and flywheel alignment 3 The belt should defle...

Page 17: ...on on the shaft until the A1 and A2 measurements are within 1 16 1 6 mm of each other 6 Tighten the motor drive pulley set screw 7 Visually inspect the motor drive pulley to verify that it is perpendicular to the drive motor shaft Points B1 and B2 of Figure should appear to be equal If they are not loosen the setscrew of the motor drive pulley and equalize B1 and B2 using care not to disturb the b...

Page 18: ...ll condense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture Troubleshooting Problem Possible Cause Solution Compressor does not run Tank has insufficient pressure When the tank pressure drops the compressor will turn on to cut in pressure No electrical power Verify wiring connection inside pressure switch and terminal box area Blown stop...

Page 19: ... or operate compressor on its own branch circuit Loose electrical connections Verify wiring connection inside pressure switch and terminal box area Defective check valve or unloader Bring the compressor to a service center Knocking Noise Loose pulley Tighten pulley set screw Loose flywheel Tighten flywheel screw Compressor mounting screws loose Tighten mounting screws Loose belt Check belt tension...

Page 20: ...essors will also generate water condensation that will form in the tank and air lines Install water and oil filter traps when needed The Typical Compressed Air Distribution System provides a guideline Contact a call Husky Customer Service for more information IMPORTANT If the tank or air lines have excessive water and or oil bring the compressor to a service center Troubleshooting continued ...

Page 21: ...sembly Torque to 25 27 lb ft Serrez de 25 À 27 lbs ft Torsión hasta 33 9 36 6 N m Torque to 14 16 lb ft Serrez de 14 À 16 lbs ft Torsión hasta 19 0 21 7 N m Torque to 9 12 lb ft Serrez de 9 À 12 lbs ft Torsión hasta 12 2 16 3 N m Torque to 8 lb ft Serrez de 8 lbs ft Torsión hasta 10 9 N m Torque to 5 lb ft Serrez de 5 lbs ft Torsión hasta 6 8 N m NOTES ...

Page 22: ...KET CRANKCASE 16 049 0048 1 CRANKCASE includes item 22 17 056 0074 1 BREATHER 18 077 0185 1 CAP 19 NA 6 SCREW M6 X 20 20 NA 6 LOCK WASHER M6 21 046 0280 1 GASKET 22 051 0099 1 BEARING 205 23 NA 1 OIL DRAIN PLUG 3 8 NPT 24 032 0072 1 OIL SIGHT GLASS W O RING 25 053 0100 1 CRANKSHAFT 26 051 0100 1 BEARING 206 27 046 0284 1 GASKET 28 077 0172 1 CARRIER 29 046 0285 1 OIL SEAL 30 044 0064 1 FLYWHEEL 12...

Page 23: ...060612 ITEM NUMBER PART NUMBER DESCRIPTION 38 165 0264 OVERHAUL KIT includes items 1 5 8 11 34 37 and 40 39 042 0116 HEAD AND VALVE PLATE ASSY includes items 1 5 8 10 11 and 12 40 046 0279 GASKETS COMPLETE SET includes items 10 12 15 21 27 and 29 040 0354 PUMP ASSEMBLY includes items 1 37 excluding 30 33 Kits Available ...

Page 24: ...24 Exploded View Unit Assembly ...

Page 25: ...VALVE 12D E105995 2 O RING 2 13 E105996 1 PUMP ASSEMBLY 755H 14 E105997 1 CONNECTOR MALE 1 4 NPT X 3 8 OD TUBE 15 E105998 2 3 8 OD TUBE COMPRESSION NUT ASSEMBLY 16 E105999 1 1 4 OD TUBE COMPRESSION NUT ASSEMBLY 17 E106000 1 OUTLET TUBE 18 E106001 1 PRESSURE RELIEF TUBE 19 E106002 1 CHECK VALVE 1 2 NPT X 3 8 OD TUBE 20 E106003 1 PRESSURE SWITCH 21 NA 1 NIPPLE 1 4 NPT 18 X 2 00 22 E106004 1 VALVE AS...

Page 26: ......

Page 27: ......

Page 28: ...stions problems missing parts Before returning to the store call Husky Customer Service 8 a m 6 p m EST Monday Friday 1 888 43 HUSKY HUSKYTOOLS COM Retain this manual for future use Document Number E105592 ...

Reviews: