background image

8

Standard Range C4PRO, C5PRO, C8PRO, & C10PRO

the door is opened.  The switch is located in the top of the door rebate (see Fig. 6 on page 7).

INSTALLING SHELVES

Fit the shelf clips to the ladder racks (see Fig. 2 on page 7) and install the shelves horizontally.  
Ensure the clips are located firmly and the shelves are secure before loading the chiller.

FITTING/REMOVING THE ILLUMINATED CANOPY

COMPETENT PERSON ONLY.  To fit the canopy, first disconnect the chiller from the power 
supply.  Remove the right hand door hinge cover.  Plug the canopy into the socket that may now 
be seen.  See Fig. 1 on page 7.  Tighten the thumb screws on both sides of the canopy to secure 
the canopy to the chiller.  Re-connect the chiller to the power supply.
To remove the canopy, first disconnect the chiller from the power supply.  Loosen the thumb 
screws on both sides of canopy, then pull out the plug for the canopy light – see Fig. 1 on page 
7.  The canopy may now be removed.  Re-fit the right hand door hinge cover.  Finally re-connect 
the chiller to the power supply.

EASY MAINTENANCE ACCESS

QUALIFIED ENGINEERS ONLY.  Husky chillers are designed for easy maintenance.  One 
feature is that the compressor, condenser and condenser fan are mounted on an easily-
accessible sliding tray.  To access this sliding tray, open the door(s) fully and loosen the two 
screws (which have now become accessible) on the top on either side of the kick plate – see Fig 
5 on page 7. Remove the kick plate by lifting it up and pulling it forward. Loosen the thumb 
screws on either side of the sliding tray – see Fig. 4 on page 7. With caution slide out the sliding 
tray no more than 300mm.

COMPRESSOR

QUALIFIED ENGINEERS ONLY. To access the compressor, slide out the sliding tray – see ‘Easy 
Maintenance Access’.

CLEANING

The condenser MUST be cleaned quarterly.  Carefully remove the kick plate (see above for how 
to remove the kick plate) and use a soft brush to clean the condenser.
The external and internal surfaces of the unit should be cleaned regularly.  Switch the unit off 
and disconnect the plug from the mains socket.  Remove the drainage hole cover (see Fig. 3 on 
page 7).  Clean the external and internal surfaces of the unit with a mild soap solution, then 
wipe dry.  Replace the drainage hole cover.  Do NOT use cleansers containing chlorine or other 
harsh cleansing agents, as these can damage the stainless steel surfaces and components.  Use 
mild soapy water to clean the gasket and seals.

GETTING SERVICE ASSISTANCE

The cooling system is a hermetically sealed circuit and does not require any maintenance other 
than regular cleaning (see ‘Cleaning’).
If the unit fails to work, first check the power supply.  If you cannot locate the reason for the 
failure, please contact your supplier, stating the model and serial number of the cabinet.  You 
may find this information on the rating plate, which is affixed inside the unit on the top right-hand 
interior wall.

Technical Support: 01455 555340 (UK)

UK PRO upright manual 2016 EDITION 2.indd   8

22/12/2015   08:57

Summary of Contents for C10PRO-H-C-HU

Page 1: ... please read this user manual thoroughly before use 2016 Husky Husky reserve the right to change specifications at any time without notice Images used are for illustration only UK PRO upright manual 2016 EDITION 2 indd 1 22 12 2015 08 57 ...

Page 2: ...C HU with canopy 230v R290 485 2227x650x719 138 C5PRO H HU without canopy 230v R290 485 1985x650x719 133 C8PRO H C HU with canopy 230v R290 795 2227x1000x719 150 C8PRO H HU without canopy 230v R290 795 1985x1000x719 143 C10PRO H C HU with canopy 230v R290 975 2227x1200x719 165 C10PRO H HU without canopy 230v R290 975 1985x1200x719 158 CONTENTS Important Notes 3 Warning Risk of electrical shock haz...

Page 3: ...pework of your refrigerator is not damaged prior to disposal You can contribute to the environmental awareness by insisting on an appropriate non polluting method of disposal WEEE COMPLIANCE Husky chillers are authorised to carry the CE Conformité Européene and WEEE Waste Electrical and Electronic Equipment Directive symbols The WEEE symbol on this chiller indicates that the product must not be di...

Page 4: ...al sensory or mental capabil ities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety BEFORE USING FOR THE FIRST TIME IMPORTANT Before switching the unit on we recommend you allow it to stand upright for 8 hours Failure to do this may result in damage to the unit Remove the wooden pallet and...

Page 5: ...on grille is blocked The chiller is not on a level firm surface or the unit may be touching other items The chiller is vibrating against a neighbouring object Chiller may be close to a water source or leak The door may be opened too often or kept open too long Action Connect the plug to the power supply Call Husky see back page or a qualified engineer Replace the fuse with one of the same rating C...

Page 6: ...inated When the chiller reaches the set temperature the Refrigeration Light will be off 2 If you do not press any button after six seconds the controller will return to its normal display To switch the chiller off press for six seconds The display will show To switch the chiller back on press for one second The display will show the cabinet temperature and the unit will enter normal working mode D...

Page 7: ...7 Exploded Diagram Technical Support 01455 555340 UK UK PRO upright manual 2016 EDITION 2 indd 7 22 12 2015 08 57 ...

Page 8: ...ick plate see Fig 5 on page 7 Remove the kick plate by lifting it up and pulling it forward Loosen the thumb screws on either side of the sliding tray see Fig 4 on page 7 With caution slide out the sliding tray no more than 300mm COMPRESSOR QUALIFIED ENGINEERS ONLY To access the compressor slide out the sliding tray see Easy Maintenance Access CLEANING The condenser MUST be cleaned quarterly Caref...

Page 9: ...ms C4PRO C5PRO Standard models no canopy C4PRO C5PRO Standard models with canopy C8PRO C10PRO Standard models no canopy 9 Technical Support 01455 555340 UK UK PRO upright manual 2016 EDITION 2 indd 9 22 12 2015 08 57 ...

Page 10: ...ms C8PRO C10PRO Standard models with canopy C8PRO C10PRO Standard models with door heater no canopy C8PRO C10PRO Standard models with door heater and canopy 10 Technical Support 01455 555340 UK UK PRO upright manual 2016 EDITION 2 indd 10 22 12 2015 08 57 ...

Page 11: ...ELECTRONIC THERMOSTAT SF 102SBQ 4 Wiring Diagram 11 Technical Support 01455 555340 UK UK PRO upright manual 2016 EDITION 2 indd 11 22 12 2015 08 57 ...

Page 12: ...mail service husky co uk Welcome to Husky the home of smart refrigeration We are a leading global refrigeration specialist with over 50 years experience in commercial refrigeration for convenience and hospitality professionals Whatever your requirements we re sure to have a good looking energy efficient model that s perfect for you 221215 Edition 2 UK PRO upright manual 2016 EDITION 2 indd 12 23 1...

Reviews: