EN
16
Fault
Probable Cause
Action
leaking water
levelled
(If applicable)
The discharge outside is
blocked
Clear the discharge outlet
Movement of water to the
drain is obstructed
Clear the floor of the appliance (if
applicable)
The water container is
damaged
Call your agent or qualified technician
The drip tray is over flowing Empty the drip tray(if applicable)
The appliance is
unusually loud
Loose nut/screw
Check and tighten all nuts and screws
The appliance has not been
installed in a level or stable
position
Check installation position and change if
necessary
Technical Specifications
Model
Voltage
Power(W)
Current
(A)
Temperature Dimensions
(mm)
HKN-PZLG2
220
~
240 V / 50 Hz 170
1,2
-2+8
℃
1075x900x700
HKN-PZLG3
220
~
240 V / 50 Hz 240
1,6
-2+8
℃
1075x1365x700
HKN-PZG2
220
~
240 V / 50 Hz 220
1,3
-2+8
℃
1510x800x1000
HKN-PZG3
220
~
240 V / 50 Hz 240
1,6
-2+8
℃
2020х800х1000
HKN-PZL2
220
~
240 V / 50 Hz 170
1,2
-2+8
℃
970x900x700
HKN-PZL3
220
~
240 V / 50 Hz 240
1,6
-2+8
℃
970x1365x700
HKN-PZG2-16 220
~
240 V / 50 Hz 240
1,6
-2+8
℃
1515x800x1000
HKN-PZG3-116 220
~
240 V / 50 Hz 320
-2+8
℃
2020х800х1000
Electrical Wiring
Appliances are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as
standard. The plug is to be connected to a suitable mains socket. Appliances are wired as
follows:
·
Live wire (coloured brown) to terminal marked L
·
Neutral wire (coloured blue) to terminal marked N
·
Earth wire (coloured green/yellow) to terminal marked E
All appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any
emergency disconnection being required they must be readily accessible.
R290 / R600a refrigerant is used for this equipment.
Caution!
Consult repair manual/power
’s guide before attempting to install or service
this
product. All safety precautions must be followed. Dispose of properly in
accordance with federal or local regulations. Risk of fire or explosion due to