INSTALLATION
15
If You Have a DC Power Supply with Daisy-Chain Connections...
The daisy-chain feature allows up to three PowerView
™
shadings to be powered by a single DC
power supply. However, each shading can operate independently. The daisy-chain feature is only
available with the DC power supply option.
■
Route the power cables from each shading to the connector, using an extension cable, if
necessary.
■
Plug an extension cable into the connector and plug the cable into the DC power supply. Two
extension cables and two connectors are used for three shadings.
■
Plug the DC power supply into a standard outlet.
Two-On-One Headrail Shadings
■
Route the power cables from each side of the shading to the connector. Use extension
cables, if necessary.
■
Plug the extension cables or power cables into the connector and plug the cable into the DC
power supply.
Proceed to “Attach Magnetic Hold-Down Brackets (Optional)” on page 16
or “Testing the Shading” on page 17.
Power Cable
from Shading
Power Cable
from Shading
Extension Cable
Connector
DC Power Supply