background image

PCM-1600

16-Station Expansion Module

Installation Guide for Pro-C

®

  

and HPC Controllers

ENGLISH

Pro-C and HPC Controllers are supplied with a base 4-station module. Additional modules may be added 
separately in increments of 3 stations (PCM-300), 9 stations (PCM-900), or 16 stations (PCM-1600). In total, 
the system may be expanded up to 23 stations.

NOTE:

 To expand your controller to 16 or 23 stations with a PCM-900 or PCM-1600, respectively, install one 

PCM-300 in the first expansion slot (stations 5–7). Then install the PCM-900 or PCM-1600 in the upper two 
expansion slots. These modules will not fit or operate in any other station output slot.

Installing PCM Modules

1.  Slide the “Power Lock” into the “Power Off” (unlocked) position. Insert any additional station modules into 

the appropriate output slots.

2. Once all modules are in place, slide the “Power Lock” into the “Power On” (locked) position to energize and 

secure the modules into the controller.

3. The controller will automatically recognize the correct number of stations. In some cases, it may be 

necessary to press the reset button on the back of the facepack or cycle power to the controller.

8–15

16–23

TERMINALS

BASE 4-STATION   PCM1600