HCC-800-PP
54
Qty:4 - ICM-800
Qty:1 - ICM-2200
STEP 1
STEP 2
STEP 3
Open the controller inner panel, and
choose the next available open slot in
the controller. Slots are numbered,
down the first column and up the
second.
Flip the blue locking lever into the
vertical unlocked position.
Tip the two tabs on one end of the
module into the mating holes in one end
of the slot, and tip the module firmly into
place.
STEP 4
STEP 5
STEP 6
Flip the locking lever into the horizontal
locked position.
Press the Reset button on the back of
the controller control panel. This is
required for the controller to recognize
the new module.
Connect field and common wiring as
needed and test.
HCC - Wire Distance to Valves