EARTH GROUND CONNECTION (LIGHTNING PROTECTION)
1. Insert the copper wire from earth ground hardware, and tighten the screw in front.
2. Minimum 10 AWG/5mm
2
wire to earth ground hardware.
3. Add copper-clad steel ground rods and/or plates sufficient to achieve 10
Ω
or less resistance at a
minimum 8’/2.5 m away from the controller.
HCC - Power Module Wiring Diagram
Power Module Terminals
1. Green
Ground
2. Yellow
24 VAC Transformer
3. Yellow
24 VAC Transformer
4. White
Sensor Common
5. Red
Rain Sensor
6. Black
Flow Meter
7. C
Common
8. P/MV
Pump or Master Valve
9. REM
Remote Control Input
10. White
Sensor Common
8. Red
Rain Sensor
9. Black
Flow Meter