Hunter 33 • Water Systems
9.2
The fresh and raw water systems consist of the following
components:
Dockside Water Supply
Fresh Water Tanks and Fills
Fresh Water Pump
A/C Cooling Pump
Raw Water Pick-up and Strainer
A/C Pick-up and Strainer
Engine Seacocks and Strainers
Fixtures and Valves
Water Heater
9.1 Water Tanks (on board water supply)
The fresh water system on your boat has one water tank
totaling 50 gallons (189L) and one fresh water fill (Fig.
9.1) located at the bow. The vent for the tank is located
on the side of the hull, at the fill. See the arrangement
drawing at the end of this chapter for locations.
Note: Whenever servicing the fresh water pumps, shut off the
DC breaker for the water system.
9.1.1 To fill the fresh water tank:
1. Make sure the potable water supply is suitable for
drinking. Not all potable water is drinking water. Check
with the dockmaster if necessary.
2. Open the water tank fill fitting. Fig. 9.1
3. Using the hose from the potable water supply, fill the
tank until water starts flowing through the vent.
4. Close the fill fitting.
•
•
•
•
•
•
•
•
•
CAUTION
!
!
Always ensure that when filling the fresh water tanks
that you are filling through the fresh water fill. Other
fills or pump outs may visually look the same. Filling
fresh water in to the waste pump out could flood
your boat, or filling the diesel fuel tank could dam-
age your fuel system.
9.1.2 Fresh Water Sanitation
NOTE: Be sure and read the OEM manuals that are supplied
with your boat, the next section is taken from one of those
manuals.
Sanitizing Potable water systems require periodic main-
tenance to deliver a consistent flow of fresh water.
Depending on use and the environment the system is
subjected to, sanitizing is recommended prior to storing
and before using the water system after a period of stor-
age. Systems with new components, or ones that have
been subjected to contamination, should also be disin-
fected as follows:
NOTE: The sanitizing procedure is in conformance with the
approved procedures of the US Public Health Service.)
1. Use the following methods to determine the amount of
common household bleach needed to sanitize the tank:
A. Multiply “gallons of tank capacity” by 0.13; the result
is the ounces of bleach needed to sanitize the tank (30
gallons X .13 = 3.9 oz bleach).
B. Use the number of liters of tank capacity to determine
the number of milliliters of bleach needed to sanitize
the tank (120 liters of tank capacity = 120 milliliters of
bleach).
2. Mix into solution the proper amount of bleach within a
container of water
3. Pour the solution (water/bleach) into the tank and fill
the tank with potable water.
4. Open all faucets (hot and cold) allowing the water to
run until the distinct odor of chlorine is detected.
5. The standard solution must have four (4) hours of
contact time to disinfect completely. Doubling the solution
concentration allows for contact time of one (1) hour.
6. When the contact time is completed, drain the tank.
Summary of Contents for H33
Page 1: ...Operator s Operator s Manual Manual H33 H33 V1 030107 P N 1031377 ...
Page 2: ......
Page 9: ...Introduction Introduction H33 H33 Chapter 1 Chapter 1 V1 030107 P N 1031377 ...
Page 14: ...Hunter 33 Introduction 1 6 Notes ...
Page 15: ...V1 030107 P N 1031377 and Documents Documents Forms Forms H33 H33 Chapter 2 Chapter 2 ...
Page 26: ...Hunter 33 Documents and Forms Maintenance Log Date Maintenance Performed Hourmeter 2 12 ...
Page 27: ...Hunter 33 Documents and Forms 2 13 Date Maintenance Performed Hourmeter Maintenance Log ...
Page 33: ...Hunter 33 Documents and Forms 2 19 Spare Parts List ...
Page 34: ...Hunter 33 Documents and Forms Dates of practice drills and onboard safety inspections 2 20 ...
Page 35: ...Hunter 33 Documents and Forms 2 21 My personal preferences for maintenance items safety gear ...
Page 36: ...Hunter 33 Documents and Forms Notes 2 22 ...
Page 37: ...Warranty Warranty H H33 33 Chapter 3 Chapter 3 ...
Page 38: ...This Page Intentionally Left Blank Hunter Warranty 3 2 ...
Page 45: ...Boating Boating Safety Safety H33 H33 Chapter 4 Chapter 4 V1 030107 P N 1031377 ...
Page 66: ...This Page Intentionally Left Blank Hunter 33 Boating Safety 4 22 ...
Page 67: ...Chapter 5 Chapter 5 Fuel Fuel Systems Systems H33 H33 V1 030107 P N 1031377 ...
Page 73: ...Fig 5 6 A Quick Fuel Filter Reference Hunter 33 Fuel Systems 5 7 ...
Page 78: ...This Page Intentionally Left Blank Hunter 33 Fuel Systems 5 12 ...
Page 80: ...This Page Intentionally Left Blank Hunter 33 Fuel Systems 5 14 ...
Page 82: ...This Page Intentionally Left Blank Hunter 33 Fuel Systems 5 16 ...
Page 83: ...Notes Hunter 33 Fuel Systems 5 17 ...
Page 84: ...Notes Hunter 33 Fuel Systems 5 18 ...
Page 85: ...Underwater Underwater Gear Gear H33 H33 Chapter 6 Chapter 6 V1 030107 P N 1031377 ...
Page 94: ...Hunter 33 Underwater Gear 6 10 This Page Intentionally Left Blank ...
Page 95: ...Hunter 33 Underwater Gear 6 11 Notes ...
Page 96: ...Hunter 33 Underwater Gear 6 12 Notes ...
Page 97: ...DC Electric DC Electric Systems Systems H33 H33 Chapter 7 Chapter 7 V1 030107 P N 1031377 ...
Page 106: ...Hunter 33 DC Electric 7 10 Notes ...
Page 108: ...Hunter 33 DC Electric 7 12 This Page intentionally Left Blank ...
Page 110: ...Hunter 33 DC Electric 7 14 This Page intentionally Left Blank ...
Page 112: ...Hunter 33 DC Electric 7 16 Notes ...
Page 113: ...AC Electric AC Electric Systems Systems H33 H33 Chapter 8 Chapter 8 V1 030107 P N 1031377 ...
Page 120: ...Hunter 33 AC Electric Systems 8 8 Notes ...
Page 122: ...Hunter 33 AC Electric Systems 8 10 This Page Intentionally Left Blank ...
Page 124: ...Hunter 33 AC Electric Systems 8 12 This Page Intentionally Left Blank ...
Page 125: ...Water Water Systems Systems H33 H33 Chapter 9 Chapter 9 V1 030107 P N 1031377 ...
Page 132: ...Hunter 33 Water Systems 9 8 This Page Intentionally Left Blank ...
Page 134: ...Hunter 33 Water Systems 9 10 This Page Intentionally Left Blank ...
Page 135: ...Waste Waste Systems Systems H33 H33 Chapter 10 Chapter 10 V1 030107 P N 1031377 ...
Page 144: ...Hunter 33 Waste and Sanitation Systems 10 10 This Page Intentionally Left Blank ...
Page 152: ...Hunter 33 Waste and Sanitation Systems 10 18 This Page Intentionally Left Blank ...
Page 154: ...Hunter 33 Waste and Sanitation Systems 10 20 This Page Intentionally Left Blank ...
Page 156: ...Hunter 33 Waste and Sanitation Systems 10 22 This Page Intentionally Left Blank ...
Page 157: ...Hunter 33 Waste and Sanitation Systems 10 23 Notes ...
Page 158: ...Hunter 33 Waste and Sanitation Systems 10 24 Notes ...
Page 168: ...Hunter 33 Engines and Transmissions 11 10 This Page Intentionally Left Blank ...
Page 169: ...Hunter 33 Engines and Transmissions 11 11 Notes ...
Page 170: ...Hunter 33 Engines and Transmissions 11 12 Notes ...
Page 171: ...and Sails Sails Rigging Rigging H33 H33 Chapter 12 Chapter 12 V1 030107 P N 1031377 ...
Page 175: ...Hunter 33 Sails and Rigging 12 5 Fig 12 6 Fig 12 7 ...
Page 179: ...Hunter 33 Sails and Rigging 12 9 5 32 4mm 1 4 Figure 12 10 Conventional Standing Rigging ...
Page 181: ...Hunter 33 Sails and Rigging 12 11 5 32 4mm 5 32 4mm Figure 12 11 Furling Standing Rigging ...
Page 183: ...Hunter 33 Sails and Rigging 12 13 Notes ...
Page 184: ...Hunter 33 Sails and Rigging 12 14 This Page Intentionally Left Blank ...
Page 185: ...Getting Getting Underway Underway H33 H33 Chapter 13 Chapter 13 V1 030107 P N 1031377 ...
Page 192: ...Hunter 33 Getting Underway 13 8 Notes ...
Page 193: ...Maintenance H33 H33 Chapter 14 Chapter 14 V1 030107 P N 1031377 ...
Page 206: ...Hunter 33 Maintenance 14 14 This Page Intentionally Left Blank ...
Page 208: ...Hunter 33 Maintenance 14 16 This Page Intentionally Left Blank ...
Page 209: ...Glossary Glossary H33 H33 Chapter 15 Chapter 15 V1 030107 P N 1031377 ...