SmartPort
for ICR Receiver
Blue: REM
Connect orange
(or blue-and-white-striped)
wire from module,
to blue wire from SmartPort
White: AC2
Red: AC1
To ET Sensor
Green
Black
Controller Connections
(SmartPort with ET and ICR)
9
Remote Control Connection
If a remote control (either Hunter ICR or SRR) receiver is to be con-
nected, connect the Orange wire (or Blue-And-White-Striped wire in
some versions) from the ET Module, to the blue ICR/SRR receiver
wire. The SmartPort wiring that connects ET Module to the controller
will complete the connection for the remote receiver.
ACC Controller Connection
The ET System is shipped with a special adapter for use with the ACC
series of controllers.
The ACC controllers have an integrated SmartPort for remote receivers
(such as the Hunter ICR remote control) on the side of the cabinet in
the metal cabinet configurations, and inside the pedestal in the plastic
pedestal configurations.
All ET System connections are made within the enclosed ET/ACC
adapter, which is then plugged into the SmartPort. The adapter allows
both ICR remote receivers and the ET System to be connected to the
ACC controller at the same time.
When installing ET System with an ACC controller, the ET Sensor con-
nections are also made at the terminal strip inside the adapter, NOT to
the ET Module cable directly. This is only true for ACC connections.