background image

52

Is there help on the web?

Yes. Visit http://www.HunterFan.com for more information. 

....................................................................................

Can I just call someone?

Sure. Our Technical Support Group is available from 8 am to 5 
pm CST. They may be reached toll-free at 1-888-830-1326.

Click Here to Read More....

Mobile friendly optimized manual:

Hunter  44155c / 44157 Thermstat Installation 

and Operation Manual

Summary of Contents for 44155C

Page 1: ...1 Form 42708 01 20120210 2012 Hunter Fan Co Set ave Set ave Set ave installation and operation manual Models 44155 44157 Programmable Thermostat English c...

Page 2: ...2...

Page 3: ...talling the Thermostat 12 Installing the Wall Plate 13 Connecting the Wires 16 Attaching the Thermostat 18 Settings 22 Methods of Operation 27 Manual Operation 28 Default Programs 32 Creating Custom P...

Page 4: ...er thermostat will provide years of reliable service and year round energy savings Please read this manual before beginning installation and save this booklet for complete operation instructions Set S...

Page 5: ...Oil Fired Boilers Oil Fired Furnace Electric Furnace Electric Air Conditioning Single Stage Heat Pump No auxilary This thermostat is not designed for multi stage heat pump systems or 110 220 V baseboa...

Page 6: ...crews and two wall anchors for mounting To install your new thermostat you will need the following supplies Flat head screwdriver Small Phillips head screwdriver Hammer Electric drill and 3 16 bit Two...

Page 7: ...NOTICE Do not disconnect the wires from the existing thermostat before reading these instructions The wires must be labeled prior to removal to ensure proper reconnection UNINSTALLING THE EXISTING UNI...

Page 8: ...8 Y RC G W Y RC G W...

Page 9: ...ng thermostat cover to access the wires from the wall Some thermostats may have multiple covers screws or other locking devices that must be removed or disengaged 3 Locate but do not disconnect the wi...

Page 10: ...ting thermostat is marked label the wire with this sticker G F G G W H B W B W B Y C M O Y 0 Y 0 RC VC RC RC RH R VR 4 RH RH 24 Volt 24 Volt cool air conditioning compressor heating fan Y1 Y1 Y1 heat...

Page 11: ...signation for proper identification If wires marked Y C are both present C may be a Common wire and should not be used If you have a wire marked C do not connect it to any terminal This wire is used o...

Page 12: ...12 W R C Y G INSTALLING THE THERMOSTAT...

Page 13: ...lease tab on the bottom of the thermostat 2 Position the new wall plate on the wall and pull the labeled wires through the opening 3 If the existing holes do not match those on the Hunter wall plate o...

Page 14: ...14 W R C Y G...

Page 15: ...nchors into the holes until they are flush with the wall 6 Reposition the wall plate on the wall pulling the wires through the opening Insert the mounting screws through the wall plate and into the an...

Page 16: ...16 G RCRHY 0W B R C G Y1 Y 0 W B Y 1 Terminal Shield CONNECTING THE WIRES...

Page 17: ...o not have both an RH and RC wire leave the jumper in place 2 Match and connect the wires from the wall to the terminals as shown Wires should be inserted behind the black terminal shields Tighten eac...

Page 18: ...18 DISABLE ENABLE RECOVERY HG HE W B Y O RH RC G SYSTEM TYPE STD HP Y1 FAN OPTION AM HEAT 4 T Thermostat Cover System Switch G RC RH Y O W B Y1 ATTACHING THE THERMOSTAT...

Page 19: ...effect when the system is set to cooling mode 2 Locate the Auto Recovery switch on the back of the thermostat If you wish to use the Auto Recovery feature verify that the switch is in the ENABLE posit...

Page 20: ...20 1 2 Tab...

Page 21: ...wall plate and press to snap the bottom tab into place Note Do not force the thermostat onto the wall plate as the terminal pins may be damaged If the thermostat does not snap into place properly the...

Page 22: ...22 reset SETTINGS...

Page 23: ...PROGRAMS If no button is pressed for 5 seconds the unit will return to the Normal Display mode To change to Celcius Co 1 Press and hold the Up button 2 Use a paperclip to press the Reset button 3 Con...

Page 24: ...24 day time AM PM...

Page 25: ...when the thermostat is in 24 hour mode Setting day and time 1 Press Day Time AM PM and current hour will flash 2 Press Up or Down to adjust the setting 3 Press Day Time again to adjust the minute sett...

Page 26: ...26 AM HEAT 4 T...

Page 27: ...am up to 4 custom temperature settings per day or utilize pre programmed settings For manual operation instructions see pages 28 31 To utilize the pre programmed settings see pages 32 33 To create cus...

Page 28: ...28 AM HEAT 2 TH MANUAL OPERATION...

Page 29: ...for the current program or permanently override all settings and adjust temperatures manually If you want to only override the current program 1 Press and hold Up or Down for one second to enter Manu...

Page 30: ...30 hold return system off heat cool HOLD...

Page 31: ...old Return until the Hold icon appears 2 Press and hold Up or Down for one second to enter Manual Override mode Release the button when the display flashes 3 Press the Up or Down buttons to adjust the...

Page 32: ...8 am 6 am Program 1 Heat 68o F 20o C Cool 78o F 26o C Program 2 Heat 60o F 16o C Cool 85o F 29o C Program 3 Heat 68o F 20o C Cool 78o F 26o C Program 4 Heat 60o F 16o C Cool 82o F 28oC 4 pm DEFAULT P...

Page 33: ...u money by optimizing energy usage in heating and cooling After setting the time and temperature scale no additional action is needed to utilize the pre programmed settings Refer to the Default Progra...

Page 34: ...34 AM PM program hold return system off heat cool CREATING CUSTOM PROGRAMS...

Page 35: ...inactivity during programming the thermostat will return to Normal Display mode When setting the program time note the AM PM indicator Press Hold Return at any time to exit Program mode 1 Slide the Sy...

Page 36: ...36 AM PM HEAT COOL SA 2 1 3 4 SU M T W TH F program hold return system off heat cool...

Page 37: ...ve to the next program number There are 4 programs per day If you do not wish to assign all 4 programs per day set at least 2 keeping in mind that the total program time must equal 24 hours 6 Repeat s...

Page 38: ...38 FILTER filter ICONS AND FEATURES...

Page 39: ...rate Follow the instructions on pages 42 43 to change batteries 2 Filter change indicator will flash after 400 hours of system use as a reminder to check or change your filter Press and hold the Filte...

Page 40: ...40 HEAT COOL system off heat cool reset...

Page 41: ...ing too fast or too slowly Press and hold both the Up and Down buttons until the word SPAN appears Use the Up or Down button to adjust the span setting Up will increase your cycle time by allowing the...

Page 42: ...42 PM COOL 4 M STAGE 1 STAGE 2...

Page 43: ...second battery power shortage mode When insufficient battery power is left the battery icon will flash alone on the display and your system will turn off The system will remain off until new batterie...

Page 44: ...44 hold return...

Page 45: ...ture to the next program setting When the thermostat is in Auto Recovery mode the display will flash alternating messages of RECO and the time Auto Recovery can be disabled by sliding the recovery swi...

Page 46: ...46...

Page 47: ...eries You must Reset and reprogram the thermostat after replacing the batteries if the thermostat has entered Error mode 7 Auto cut off automatically turns the system off if the temperature rises abov...

Page 48: ...restarted to prevent compressor damage due to rapid cycling 3 Resetting the unit To restore the thermostat to the original factory settings press the reset button with a paperclip This will erase any...

Page 49: ...stat from the wall plate and set the HG HE switch to the correct position 3 My display is erratic Reset the thermostat and reprogram your settings 4 The program will not change at my desired setting C...

Page 50: ...ns on or off to protect the compressor 5 c Check the circuit breakers and switches to ensure there is enough power to the system 5 d Replace the batteries 5 e If applicable make sure the furnace blowe...

Page 51: ...erate when the thermostat is in the off position 7 a Replace unit 8 The LCD screen permanently reads HI LO or ERR 8 a Replace unit 9 How do I just operate my thermostat manually 9 a Manual operation i...

Page 52: ...nformation Can I just call someone Sure Our Technical Support Group is available from 8 am to 5 pm CST They may be reached toll free at 1 888 830 1326 Click Here to Read More Mobile friendly optimized...

Reviews: