4
Please read these instructions carefully
This appliance is intended for use on a gas installation with a governed meter.
It is important that your stove is correctly installed as Hunter Stoves Limited cannot accept
responsibility for any fault arising through incorrect installation. Any unauthorised changes to
the stove will negate the warranty.
TECHNICAL DATA
0558
NATURAL
GAS
MANUAL/REMOTE
LPG
MANUAL/REMOTE
Energy Efficiency
Class
Nominal Gas
Pressure
20mbar
37mbar
Main Burner Injector
(mm)
0.59 x 7
1.03
Pilot Injector (mm)
0.35
0.27
Burner Aeration
Φ
7
Φ
9
Supply Gas
Type/Category
G20/I
2H
G31/l
ɜp
Energy Efficiency
71
75
Injector
Type/Marking
380
103
Heat Input (Gross)
Full
Low
4.7kW
3.5kW
4.7kW
3.2kW
Gas Flow Rate (m
3
/h)
Full
0.447
0.176
NO
x
Class
4
5
Efficiency Class
2
2
Countries of
Destination
AT, BG, CH, CZ, DK, EE, ES, FI,
GB, GR, HR, IE, IT, LT, LV, NO,
PT, RO, SE, SI ,SK, TR
BE, CH, CZ, ES, FR, GB, GR, IE,
IT, LT, NL, PL, PT, SI, SK
Summary of Contents for AVALON 4 Series
Page 5: ...5 STOVE DIMENSIONS AVALON 4 CONSORT 5 HAWK 4 MKII...
Page 13: ...13 TROUBLESHOOTING...
Page 14: ...14...
Page 26: ...26 SERVICE RECORDS...