Chapter 6 Testing
Kindly perform the following test operations after installing the device.
Step 1 Kindly install the device in accordance with the installation diagram and wiring
diagram. When device is turned on, the controller beeps after 3-5 sec. After which
the Status LED will start to flash green.
Step 2 Add a card number(Kindly refer to “Function Setting” for more information
Step 3 Press exit button to activate door relay and electronic lock will activate for 4 sec.
Step 4 Controller produces three short beeps upon valid card swipe and status LED lits
green. If invalid card was swiped, the controller will sound three long beeps and
status LED will lit red.
Step 5 Swipe a valid card to activate Door Relay. Door opens and OK/ERR LED
simultaneously turns green. For valid cards, controller will sound 3 short beeps; for
invalid cards, controller will sound 3 long beeps..
Step 6 After 4 sec, (default unlock door time), door relay deactivates and OK/ERR LED
extinguishes. For other functions, kindly refer to the instructions on the
succeeding chapters, or inquire your engineers.
Step 7 For other functions, kindly refer to the instructions on the succeeding chapters, or
inquire your engineers.
HUNDURE
49
RAC-510/511PE Hardware manual
Summary of Contents for RAC-510PE
Page 1: ...RAC 510 511PE Standalone Access Controller Hardware Manual Version 1 0...
Page 7: ...Chapter 2 Physical Dimension 2 1 Dimension Scale mm HUNDURE 7 RAC 510 511PE Hardware manual...
Page 11: ...RAC 511 HUNDURE 11 RAC 510 511PE Hardware manual...
Page 14: ...3 2 3 Alarm Connection With ACU 30 for digital output HUNDURE 14 RAC 510 511PE Hardware manual...
Page 17: ...With ACU 30 for digital output HUNDURE 17 RAC 510 511PE Hardware manual...
Page 18: ...3 2 6 Slave Reader Connection HUNDURE 18 RAC 510 511PE Hardware manual...
Page 21: ...Chapter 5 Setting 5 1 ID Setting For RAC 510 only HUNDURE 21 RAC 510 511PE Hardware manual...