background image

Returning Your Unit for Service

Before sending your unit in for repair, please contact the factory, either by
phone or by email, to obtain a Repair Authorization Number for your unit.
Please have your product model name and serial number available

before

calling the factory. If you contact the factory by e-mail, please include your
product model name and serial number in the e-mail, and use Request
for Repair Authorization Number for your e-mail subject header. You
should include your Repair Authorization Number in all subsequent
communications about your unit.

For IN-WARRANTY service, complete the following steps:

Obtain a Repair Authorization Number from Techsonic Industries
Customer Resource Center.

Tag  product with your customer name, street address, phone
number and your assigned Repair 

Authorization Number.

Include a brief written description of the problem.

Include a copy of your receipt (to show proof and date of purchase).

Return product freight prepaid to Techsonic Industries, Inc., using an
insured carrier with 

delivery confirmation.

For OUT-OF-WARRANTY service, complete the following steps:

Obtain a Repair Authorization Number from Techsonic Industries
Customer Resource Center.

Included payment in the form of credit card number and expiration
date, money order or personal check. Please do not send cash.

Tag  product with your customer name, street address, phone
number and your assigned Repair Authorization Number.

Include a brief written description of the problem.

Return product freight prepaid to Techsonic Industries, Inc., using an
insured carrier with 

delivery confirmation.

Contacting Humminbird

Contact the Humminbird Customer Resource Center in any of the following ways:

By Telephone 

(Monday - Friday 8:00 a.m. to 4:30 p.m. Central Standard Time):

334-687-0503

By e-mail 

(typically we respond to your e-mail within three business days):

[email protected]

For direct shipping, our address is: 

Techsonic Industries, Inc.

Service Department

108 Maple Lane

Eufaula, AL  36027 USA

CUSTOMER RESOURCE CENTER

SERVICE POLICY / SERVICE PROCEDURES

15

Summary of Contents for Legend 2000

Page 1: ...Operations Manual Operational instructions for Humminbird Legend 2000 Series including the Legend 2000 2005 2000 Deep and 2005 Deep...

Page 2: ...nbird com WARNING This device should not be used as a navigational aid to prevent collision grounding boat damage or personal injury When the boat is moving water depth may change too quickly to allow...

Page 3: ...Speed 9 Sonar View 9 Light 9 Contrast 9 RTS Window 9 Surface Clutter 10 White Line 10 Filter 10 Depth Alarm 10 Temp Alarm 11 Fish Alarm 11 Fish Sensitivity 11 Fish ID 11 Simulator 11 Units 11 Language...

Page 4: ...SITIVITY and FISH ID provide advanced signal processing to identify fish and show their depth and relative size from either beam Powering Up the Unit After installation turn the LEGEND 2000 SERIES on...

Page 5: ...L knob again If no adjustments are made after a few seconds the CONTROL PANEL list is removed automatically Range Knob The RANGE knob adjusts the depth ranges used on the display The RANGE knob has sl...

Page 6: ...ft bottom shows more gray below Structure appears above the bottom as a cluster of lines with varying lengths and gray shades Fish appear as smaller groupings of sonar returns between the bottom and s...

Page 7: ...00 SERIES is also capable of showing layers of water having different temperatures These temperature differences called thermoclines appear at different depths depending on current conditions A thermo...

Page 8: ...SETTING READOUT shows the status when CONTROL PANEL is not selected To select a CONTROL PANEL feature for adjustment follow these steps 1 Press the CONTROL PANEL knob A list of options appears on the...

Page 9: ...r of the CHART WINDOW 3 Turn the RANGE knob clockwise until the second return is visible on the display 4 To return the depth range to normal viewing rotate the RANGE knob counterclockwise until the d...

Page 10: ...etail if you are looking for fish at a specific depth To adjust the depth ranges manually follow these steps 1 Make sure the Legend 2000 Series is operating in Manual mode 2 Push the Range knob An adj...

Page 11: ...T setting is retained in memory after the unit is turned off as long as it is set between 6 and 10 The factory setting is 8 RTS Window RTS WINDOW selects the width of the window dedicated to REAL TIME...

Page 12: ...mittently until the boat moves to deeper water The DEPTH ALARM can be muted by pressing the CONTROL PANEL knob once muted the alarm will not sound again until the boat moves to water deeper than the D...

Page 13: ...f The factory setting is 0 Fish ID FISH ID Deep Models only uses advanced signal processing to evaluate further any sonar return between the surface and the bottom If the return meets certain addition...

Page 14: ...with proper operation These bubbles dissipate with time or you can wipe the face of the transducer with your fingers after the transducer is in the water Heat Damage Never leave the LEGEND 2000 SERIE...

Page 15: ...ERIES will work reliably in water 2 6m or deeper Remember that the depth is measured from the transducer not necessarily from the surface of the water 5 The unit comes on before I press POWER and won...

Page 16: ...the exclusion of incidental or consequential damages so the above exclusions may not apply to you You may also have other rights which vary from state to state A separate Warranty is provided by inter...

Page 17: ...purchase Return product freight prepaid to Techsonic Industries Inc using an insured carrier with delivery confirmation For OUT OF WARRANTY service complete the following steps Obtain a Repair Author...

Page 18: ...g Frequencies 50 200 kHz Power Output 4000 Watts Peak to Peak 500 Watts RMS Area of Coverage 20 and 74 at 10 dB Power Requirement 10 20 VDC Display 16 level FSTN Grayscale LCD LCD Matrix 240 H x 240 V...

Reviews: