background image

Sonar View

S

ONAR

V

IEW

(Deep Models only)

selects the source of the
sonar information being
displayed. 200kHz displays
sonar information and 

F

ISH

ID

from the 200kHz beam only.
50kHz displays sonar
information and 

F

ISH

ID

from

the 50kHz beam only. 

S

PLIT

S

CREEN

presents the sonar

information from the 200kHz
and 50kHz beams
simultaneously in side-by-
side windows. 

200

K

H

Z

/50

K

H

Z

displays the sonar
information from the 200kHz
beam and target information
from the 50kHz beam.

The 

S

ONAR

V

IEW

setting is retained in memory after the

unit is turned off. The factory setting is 

200

K

H

Z

.

Light

L

IGHT

activates the display

backlight and selects the
brightness level. The
backlight is manually-
controlled except when the unit first powers up.
During initial power up, the backlight turns on at full
brightness so the display will be visible at night. The
backlight will then begin to decrease in intensity
automatically until it is off in order to save energy.
Selecting the 

C

ONTROL

P

ANEL

L

IGHT

choice stops the

automatic off process, keeping the backlight on at the
intensity level selected.

The Light setting defaults to factory settings after the
Legend 2000 Series is turned off. The factory setting
is 

O

N

full at power up and automatic decrease to 

O

FF

.

Contrast

C

ONTRAST

enhances the

viewability of the LCD by
making it darker or lighter.
Selecting a higher number
darkens the display; selecting a lower number lightens
the display. The 

L

EGEND

2000 S

ERIES

uses sophisticated

electronics to adjust the contrast level automatically;
however, at times of extreme heat or cold, manually
adjusting the contrast for best display may be needed.

The 

C

ONTRAST

setting is retained in memory after the unit is turned off as

long as it is set between 6 and 10. The factory setting is 

8

.

RTS Window

RTS W

INDOW

selects the width of

the window dedicated to R

EAL

T

IME

S

ONAR

™. Selecting 

N

ARROW

decreases the width of the

RTS W

INDOW

leaving more space for the 

C

HART

W

INDOW

, but

some sonar returns will not be visible. Selecting 

W

IDE

makes the 

RTS W

INDOW

wider and shows more of the

sonar intensity information, but less space on the LCD
is available for sonar history. Selecting 

O

FF

turns off the

RTS W

INDOW

and the entire LCD shows sonar history.

Note: When the RTS Window is adjusted to Wide, no grayscale
information is shown.

The 

RTS W

INDOW

setting is retained in memory after the

L

EGEND

2000 S

ERIES

is turned off. The factory setting is

N

ARROW

.

Surface Clutter

S

URFACE

C

LUTTER

eliminates most

sonar returns near the water
surface caused by trapped air,
boat wakes and temperature
inversions. Most surface clutter appears on the
display because the strongest sonar returns come
from the shallowest objects. The 

L

EGEND

2000 S

ERIES

uses

a sophisticated feature called TVG (Time Variable
Gain) to overcome surface clutter and counteract the
effect of depth on sonar return strength. The level 1
setting is optimal for making sonar information from
all depths appear uniformly. Many users, however,
prefer to see more surface clutter than this setting
shows. Selecting a higher number shows more
surface clutter, but sonar returns nearest the surface
will appear more intense than they actually are. 

The 

S

URFACE

C

LUTTER

setting is retained in memory after the

L

EGEND

2000 S

ERIES

is turned off. The factory setting is 

4

.

9

USING THE LEGEND 2000 SERIES

CHART SPEED / SONAR VIEW / LIGHT / CONTRAST / RTS WINDOW

Split window 50kHz/200kHz,
shown with metric depth, °C
and kph digital readouts
available on international
models.

Summary of Contents for Legend 2000

Page 1: ...Operations Manual Operational instructions for Humminbird Legend 2000 Series including the Legend 2000 2005 2000 Deep and 2005 Deep...

Page 2: ...nbird com WARNING This device should not be used as a navigational aid to prevent collision grounding boat damage or personal injury When the boat is moving water depth may change too quickly to allow...

Page 3: ...Speed 9 Sonar View 9 Light 9 Contrast 9 RTS Window 9 Surface Clutter 10 White Line 10 Filter 10 Depth Alarm 10 Temp Alarm 11 Fish Alarm 11 Fish Sensitivity 11 Fish ID 11 Simulator 11 Units 11 Language...

Page 4: ...SITIVITY and FISH ID provide advanced signal processing to identify fish and show their depth and relative size from either beam Powering Up the Unit After installation turn the LEGEND 2000 SERIES on...

Page 5: ...L knob again If no adjustments are made after a few seconds the CONTROL PANEL list is removed automatically Range Knob The RANGE knob adjusts the depth ranges used on the display The RANGE knob has sl...

Page 6: ...ft bottom shows more gray below Structure appears above the bottom as a cluster of lines with varying lengths and gray shades Fish appear as smaller groupings of sonar returns between the bottom and s...

Page 7: ...00 SERIES is also capable of showing layers of water having different temperatures These temperature differences called thermoclines appear at different depths depending on current conditions A thermo...

Page 8: ...SETTING READOUT shows the status when CONTROL PANEL is not selected To select a CONTROL PANEL feature for adjustment follow these steps 1 Press the CONTROL PANEL knob A list of options appears on the...

Page 9: ...r of the CHART WINDOW 3 Turn the RANGE knob clockwise until the second return is visible on the display 4 To return the depth range to normal viewing rotate the RANGE knob counterclockwise until the d...

Page 10: ...etail if you are looking for fish at a specific depth To adjust the depth ranges manually follow these steps 1 Make sure the Legend 2000 Series is operating in Manual mode 2 Push the Range knob An adj...

Page 11: ...T setting is retained in memory after the unit is turned off as long as it is set between 6 and 10 The factory setting is 8 RTS Window RTS WINDOW selects the width of the window dedicated to REAL TIME...

Page 12: ...mittently until the boat moves to deeper water The DEPTH ALARM can be muted by pressing the CONTROL PANEL knob once muted the alarm will not sound again until the boat moves to water deeper than the D...

Page 13: ...f The factory setting is 0 Fish ID FISH ID Deep Models only uses advanced signal processing to evaluate further any sonar return between the surface and the bottom If the return meets certain addition...

Page 14: ...with proper operation These bubbles dissipate with time or you can wipe the face of the transducer with your fingers after the transducer is in the water Heat Damage Never leave the LEGEND 2000 SERIE...

Page 15: ...ERIES will work reliably in water 2 6m or deeper Remember that the depth is measured from the transducer not necessarily from the surface of the water 5 The unit comes on before I press POWER and won...

Page 16: ...the exclusion of incidental or consequential damages so the above exclusions may not apply to you You may also have other rights which vary from state to state A separate Warranty is provided by inter...

Page 17: ...purchase Return product freight prepaid to Techsonic Industries Inc using an insured carrier with delivery confirmation For OUT OF WARRANTY service complete the following steps Obtain a Repair Author...

Page 18: ...g Frequencies 50 200 kHz Power Output 4000 Watts Peak to Peak 500 Watts RMS Area of Coverage 20 and 74 at 10 dB Power Requirement 10 20 VDC Display 16 level FSTN Grayscale LCD LCD Matrix 240 H x 240 V...

Reviews: