background image

ULTRASOUND EQUIPMENT USER MANUAL

22

Careful

1. Sundry, water cup, etc. are not permitted on the operation panel.
2.

It is forbidden to pull the plug before shut off the power switch.

The correct use of the probe

Careful

1.

Before starting up the instrument, make sure the installation of the probe is correct and reliable.

2.

Power on, but without the probe, don't touch metal parts of the probe socket on the host to

prevent electric shock.

3. The probe should not be impacted with sharp and hard object, it is forbidden to collision

probe acoustic window, and otherwise it will cause damage of the probe.

4. Probe for a long time using will cause fever, during the suspension diagnosis, should press

the "frozen" button to make the probe to stop working.

5. The probe’s waterproof grade is IPX7, submerged probe for short periods of time shall not

exceed 5 mm acoustic window position.

6. Using unqualified coupling agent can make acoustic window corrode and damage, should use

medical ultrasonic coupling agent.

7. The coupling agent only can be used in the probe head, carefully clean after using.

8.

Check the probe frequently, if found there is any breakage, crack on the surface of cable or

probe, should be shut down and stop using immediately.

9. Probe is forbidden to heat. If the probe temperature is lower than the room temperature, it can be

heated naturally before using.

10. Do not insert or take down the probe in electric situation.
11. After

physician training then obtain the professional qualification, can use the cavity probe to operate.

5.2 Starting Up

Summary of Contents for MT128V

Page 1: ...ULTRASOUND EQUIPMENT USER MANUAL 1 HUMAN FULL DIGITAL ULTRASONIC DIAGNOSTIC INSTRUMENT LED USER MANUAL MT128V...

Page 2: ...curity Features 12 Chapter 2 Functions Technical Indexes and Configuration 13 2 1 Operating Environment 13 2 2 Main Functions 13 2 3 Main Technical Indexes 14 2 4 Configuration 14 Chapter 3 Operation...

Page 3: ...ing gestational age 30 5 9 8 AC Abdominal long measuring gestational age 31 5 9 9 Gestational age data report page 32 5 10 Notes 32 5 11 Gender Notes 33 5 12 Body Mark Notes 33 5 13 Setting the Time 3...

Page 4: ...ction 39 6 5 Insurance Tube Replaced 39 Chapter 7 Fault Checking and Ruled Out 40 7 1 Fault Checking Need Attention 40 7 2 Fault Checking and Ruled Out 40 Chapter 8 Transportation and Storage 41 8 1 T...

Page 5: ...manufacturer can provide for a period of one year free warranty service Other artificial damage like user tear up the seals faulty operation etc the manufacture do not provide free maintenance servic...

Page 6: ...ng and storage in the assignments need to pay attention to to ensure the safety of the instrument Form 2 the Description of Graphics symbols abbreviations NO Graphics Symbols Abbreviations Name Meanin...

Page 7: ...e of the probe Package indicative mark On the packing cases are listed in form 3 packaging storage and transportation it is used to indicate when transportation loading and unloading and storage in th...

Page 8: ...The instrument can t use with cardiac defibrillator and high frequency surgery or treatment equipment to prevent electric shock or damage to the instrument on patients 8 The instrument is forbidden t...

Page 9: ...order to avoid possible electric shock risk Any instrument maintenance and upgrade must be authorized by the manufacturer training and service personnel 10 Sundry water cup etc are not permitted on t...

Page 10: ...k or by image viewer has measurements of distance area circumference heart rate gestational weeks BPD GS CRL FL HC OFD TTD AC 8 measurement kinds and so on Chinese and English transformation pseudo co...

Page 11: ...3 The probe driven by the high voltage will change the electric signal into ultrasonic vibration and the ultrasonic wave is transmitted into human body 4 The ultrasonic wave produces the reflection s...

Page 12: ...sed in the injured part 1 5 Security features Safety features of the instruments are as follows 1 5 1 Prevent electric shock type type I 1 5 2 Shock proof of degree type B applied part 1 5 3 Applicati...

Page 13: ...and English translation Transformation in both English and Chinese in interface Zoom Local x 2 0 magnification rate Dynamic range 0 120dB adjustable Frequency T35R60B convex array probe real time sca...

Page 14: ...R60 frequency of 3 5 MHz Optional probe T65R13B type cavity probe 80 elements R13 frequency of 6 5 MHz Basic performance as below NO Name of technical indexes Type T35R60B convex array probe Type T65...

Page 15: ...Figure The operation panel is as follows Figure 3 1 Control Panel 3 2 Key text graphics enter numbers or marks enter characters or marks Space Make notes including hospital name name and age of patie...

Page 16: ...tance measurement Circumference area measurement Heart rate measurement Gestational weeks gestation measurement mode Escape from the measurement and note Time set click arrow keys to move the cursor S...

Page 17: ...ight under M mode Magnifies image Partial image magnification Puncture guidance function Image memory Up Down Clear the measurement and the note Positive and negative image selection Chinese English t...

Page 18: ...version Select probe Up and down flip Reset the unit GAIN Adjust the overall gain TGC Adjust the gain applied to the near field of the image TGC Adjust the gain applied to the far field of the image B...

Page 19: ...the power needs to use extended patch panel please choose a product with the safety certification Attention 1 When unpacking and installation instrument to should take put down gently 2 Instruments u...

Page 20: ...nd wire provide by the manufacturer which is in the packing box Make sure one end of the wire is connected with ground pole and the other end is connected with the ground The connection must be safe e...

Page 21: ...he direction or position of the jamming equipment 3 Increase the distance between the interference equipment and the instrument Chapter 5 Method of Application 5 1 Caution When using the instrument pl...

Page 22: ...sis should press the frozen button to make the probe to stop working 5 The probe s waterproof grade is IPX7 submerged probe for short periods of time shall not exceed 5 mm acoustic window position 6 U...

Page 23: ...is a need to adjust the total gain the TGC display brightness and contrast to make the image s contrast and brightness and gain to a best state The interface is shown hospital name gender age year mo...

Page 24: ...nly when it is in the magnification of 1 0 e Press The instrument works in M mode Note this function only works for 3 5MHz convex array probe in M mode 5 4 Image Magnification Selection When 3 5MHz co...

Page 25: ...th when the cursor is fixed at the start point of the measurement in the M area under BM mode Measurement can not be carried on in the mode of annotation time setting and menu functions 5 7 Circumfere...

Page 26: ...to confirm the start point of measurement d Press or touch the trackball to select the end point of measurement peak trough of the electrocardiogram e Press will display measured data on the right of...

Page 27: ...e 5 9 1 BPD Bipartitely Diameter Press or to exit from other operations before measurement a Press will display the cursor b Press or touch the trackball to select the start point of the measurement c...

Page 28: ...c Press to confirm the start point of the measurement d Press or touch the trackball to select the end point of the measurement and the gestational weeks expected date of confinement and the data of...

Page 29: ...Step d and Step e to carry on another measurement g Press to exit from the gestational weeks measurement h Press to clear the measurement mark after exited from the measurement 5 9 4 FL Femur Length P...

Page 30: ...s to confirm the center of the head circumference d Press or touch the trackball should put the fetus head image into the elliptical measurement cursor the edge of the ellipse cursor is more close to...

Page 31: ...nal week measurement h After exited gestational week measurement press to clear the measurement mark of OFD 5 9 7 TTD Transverse Trunk Diameter a Press to highlight OFD on the right side cursor appear...

Page 32: ...displayed AC XX X cm G A XX weeks EDD 20XX year XX XX month day G XXXX XXX g f Repeat step b to step e to carry on another measurement g Press the button to exit the gestational week measurement h Aft...

Page 33: ...trace ball to move the cursor when noting characters in full screen Press to newline the cursor Press to transform between big and small letters the screen will reveal Caps at the right bottom of the...

Page 34: ...y mark noting 5 13 Setting the Time Exit from other operations before setting Press will display the following information TIMESE MENU Year 20 Mouth Day Hours Minutes Week Hospital name Contains the y...

Page 35: ...ation works in three section of focusing patterns c Press FO 2 3hows on right flank of the screen demonstrates This instrumentation works in two section of focusing patterns d Press FO 2 shows on righ...

Page 36: ...with 4 patterns gamma correlation with 8 patterns COLOR 16 pseudo colors only effective with SVGA displayer MS scanning speed under M BM mode 8 type to choice only effective under M BM mode Press Esc...

Page 37: ...fication Under frozen state press key a magnified box shows on the screen the image in the box is shown on the right as image multiplying factor of 2 0 press and other direction key or move the trackb...

Page 38: ...g noting or setting press to select the language 5 28 U Disk image storage When scanning choice the image to freeze which need to be stored or after frozen bring up the permanent image insert the U di...

Page 39: ...and the charge duration for each time is about 4 hours 6 2 3 If the instrument has not been used for a long time please place the instrument in the box 6 3 Probe Maintenance 6 3 1 The probes are vulne...

Page 40: ...is not bright fan does not turn 1 Whether a power outage 2 The power cord plugs loose 3 Insurance tube fuse 1 Energized before using 2 Plug the power cord plug tightly 3 Replace the new insurance tub...

Page 41: ...t Ambient temperature range 10 55 Range of relative humidity 80 or less Atmospheric pressure range 500hPa 1060hPa 8 3 Transportation The packing box is equipped with the simple quakeproof facility whi...

Reviews: