INTRODUCTION

This manual is considered as a part of the instrument; it has to be at the operator’s hand as well as at the

maintenance operator’s availability. For accurate installation, use and maintenance, please read the following

instructions carefully. In order to avoid instrument or personal damages, carefully read the ”GENERAL SAFETY

WARNINGS”, describing the suitable operating procedures. In case of breakdowns or any troubles with the

instrument, apply to the local Technical Service.

2

 

USER WARRANTY

HUMAN warrants that instruments sold by one of its authorised representatives shall be free of any defect in

material or workmanship, provided that this warranty shall apply only to defects which become apparent within

one year from the date of delivery of the new instrument to the purchaser.

The HUMAN representative shall replace or repair any defective item at no charge, except for transportation

expenses to the point of repair.

This warranty excludes the HUMAN representative from liability to replace any item considered as expendable in

the course of normal usage, e.g.: lamps, valves, syringes, glassware, fuses, diskettes, tubing etc.

The HUMAN representative shall be relieved of any liability under this warranty if the product is not used in

accordance with the manufacturer's instructions, altered in any way not specified by HUMAN, not regularly

maintained, used with equipment not approved by HUMAN or used for purposes for which it was not designed.

HUMAN shall be relieved of any obligation under this warranty, unless a completed installation / warranty

registration form is received by HUMAN within 15 days of installation of this product.

This warranty does not apply to damages incurred in shipment of goods. Any damage so incurred shall be reported

to the freight carrier for settlement or claim.

3

 

INTENDED USE OF THE INSTRUMENT

 The instrument has to be used for the expected purposes and in perfect technical conditions, by qualified

personnel, in working conditions and maintenance operations as described in this manual, according to the

GENERAL SAFETY WARNINGS. This manual contains instructions for professional qualified operators.

4

 

  GENERAL SAFETY WARNINGS

Use only chemical reagents and accessories specified and supplied by HUMAN and/or mentioned in this manual.

Place the product so that it has proper ventilation.

The instrument should be installed on a stationary flat working surface, free from vibrations.

Do not operate in area with excessive dust.

Work at room temperature and humidity according to the specifications listed in this manual.

Do not operate this instrument with covers and panels removed.

Only use the power cord specified for this product, with the grounding conductor of the power cord connected to

earth ground.

Use only the fuse type and rating specified by the manufacturer for this instrument, use of fuses with improper

ratings may pose electrical and fire hazards.

To avoid fire or shock hazard, observe all ratings and markings on the instrument.

Do not power the instrument in potentially explosive environment or at risk of fire.

Prior to cleaning and/or maintaining the instrument, switch off the instrument and remove the power cord.

For cleaning use only materials specified in this manual, otherwise parts may become damaged.

It is recommended always to wear protective apparel and eye protection while using this instrument.

Respective warning symbols, if appearing in this manual, should be carefully considered.

Summary of Contents for HUMAX 4K

Page 1: ...Gtl w 3J User Manual Cat No 15210 100...

Page 2: ...i Qduhrhnm Khrs ne sgd L mt k No DATE Rev REVISION DESCRIPTION 1 01 2007 01 First edition...

Page 3: ...ii...

Page 4: ...llation of this product This warranty does not apply to damages incurred in shipment of goods Any damage so incurred shall be reported to the freight carrier for settlement or claim 3 INTENDED USE OF...

Page 5: ...at least potentially infectious Before doing any servicing on the instrument it is very important to thoroughly disinfect all possibly contaminated parts Before the instrument is removed from the labo...

Page 6: ...sibly contaminated parts Before the instrument is removed from the laboratory for disposal or servicing it must be decontaminated Decontamination should be performed by authorised well trained personn...

Page 7: ...b...

Page 8: ...lock System 4 5 Instructions for Use 5 5 1 Schematic Drawing 5 5 2 Controls and Indicators 6 5 3 Preparing The Run 6 5 4 Programming 7 5 5 Program Recall 7 5 6 Starting Running and End Of Run 7 5 7 Er...

Page 9: ...does not allow the centrifuge to operate or the rotor to spin if the lid is not closed The lid locking system allows the lid to be opened when the program ends by pressing a single key There are audib...

Page 10: ...balance The central hole of the rotor and the motor shaft must also be kept clean and dry at all times RDGLQJ Each tube insert must be the same weight as the one diametrically opposite for balancing C...

Page 11: ...d set step 10 rpm Timer set range 1 99 minutes and hold position Timer set step 1 minute Motor Induction Motor Supply Values 230 V 50 Hz Power Consumption 350 W External Dimensions WxDxH mm 274 x 355...

Page 12: ...5 10 XPDQ X0D User Manual 5 Instructions for Use 6FKHPDWLF UDZLQJ Figure 1...

Page 13: ...o set the speed and time during programming and to check the RCF value during the operation 5 Pulse Key Causes the motor to increase to the maximum speed The motor will continue to spin at that speed...

Page 14: ...otor stops spinning When the program is completed END is shown on the speed display 1 and the warning beep sounds to indicate to the user that program has ended The warning beep will continue to sound...

Page 15: ...ere hazardous substances including radioactive chemicals are frequently found Always use the appropriate decontamination procedures where the rotor is exposed to these chemicals Examples of commonly u...

Page 16: ...DLO No daily cleaning is required except in the case of accidental glass breakage or a large amount of spillage in the bowl HHNO Clean the bowl and the accessories with a cotton wool pad dipped in 70...

Page 17: ...10 10 8 Electrical Circuit Diagram...

Page 18: ...HUMAN Gesellschaft f r Biochemica und Diagnostica mbH Max Planck Ring 21 65205 Wiesbaden Germany Tel 49 61 22 99 88 0 Fax 49 61 22 99 88 100 e Mail human human de www human de 01 2007 01...

Reviews: