Chapter 1 • Introduction
!
1038056-0001 Revision A
9
Installation and
commissioning
The installation and commissioning of the HX260 satellite router
is a multi-step process. The workflow and chapter reference
numbers for the process steps follow.
1. Preparing the satellite router for installation
Chapter 2 – on page 11
2. Assembling the HX260 satellite router
Chapter 2 on page 11
3. Commissioning the HX260 satellite router
Chapter 3 – on page 19
4. Connecting the satellite router to a computer
Chapter 4 – on page 49
Commissioning is the process of registering an HX260 satellite
router for service. During the commissioning process you may
use auto selection or manual entry of parameters.
"
Manual Commissioning - This mode requires you to enter all
parameters manually.
"
Satellite Based Commissioning - Allows you to choose the
Network Access Provider (NAP) from a list. Many of the
commissioning parameters are automatically configured for
the provider chosen. You can also select satellite transponder
information.
Maximum Input Level
-8 dBm (Composite)
Input Return Loss
>8 dB (Min) from 950 MHz to 2150 MHz into 75 ohm
Symbol rates
256 ksps, 512 ksps, 1.024 Msps and 2.048 Msps
Note:
The HX260 requires an input frequency accuracy of +/-
35kHz (LNB and transponder combined). The LNB must be a
phase locked loop (PLL) LNB with an external or internal
reference. For internal reference LNBs, the frequency stability
should be +/- 3 ppm to maintain less than +/- 35kHz with
transponder offsets. External reference LNBs must be able to lock
to a 10MHz signal provided though the IFL cable.
Note:
When using a 1.8m or larger antenna with this indoor unit
(IDU), use 100 ft minimum of RG-11 IFL cable.
Table 9: Mesh receiver specifications
Parameter
Value