Import/Export
Model 220 Configuration Data Export / Import Procedure
Rev 1.0.0
This appendix defines the steps to perform a Configuration Data Export & Import from the Model 220
projector to a Host Computer. The Host Computer can be any system that has RS232 download and upload
capability, including an IBM-PC compatible, an Apple MacIntosh, or a UNIX system. This paper describes
the procedures for an IBM-PC running the Windows 3.1 OS. We will use the Windows “TERMINAL”
application for communication with the projector. Other Terminal emulation programs can be used
(ProComm, .), but all testing has been done with the TERMINAL application.
Note 1
: The TERMINAL application setup is the same as for controlling the projector via an ANSI
TERMINAL (see Model 220 User’s Guide, Section 4.11).
Note 2
: Export/Import can be performed on either Port A or Port B. The Port must be configured for
ANSI Terminal. Port A speed is determined by DIP SWITCH #4 on the System Controller board. DOWN
is 9600 baud, UP is 19200 Baud. Port B can be configured for 2400, 9600 (default), or 19200 through the
Comm Setup Menu. If both Port A and Port B are ANSI Terminals, PORT A must be used for
Export/Import, so to use Port B, set Port A Device = None or Switcher, Port B Device = ANSI.
Remember
to Power Off (P) and HW RESET (Push RESET button -
figure 5-1 in Service
Manual-
or Circuit Breaker-
on rear panel
) after changing any configuration parameters.
WARNING
: If you use 19200 Baud, your computer must have a 16550 UART installed on the Comm
Port. An unbuffered 8550 UART will lose data during EXPORT. This data loss cannot be detected until a
later IMPORT is attempted. Use 9600 if you are not sure. In all cases use SOFTWARE FLOW
CONTROL (XON/XOFF).
WARNING
: Laptop computer users must disable Advance Power Management (APM) during an Export.
APM power pulling causes loss of data.
EXPORT
1.
Make sure the Windows TERMINAL program is configured for SOFTWARE FLOW CONTROL
(XON/XOFF). A corrupt Export file will result if SW flow control is not used.
2.
Choose the directory and filename for saving the Export Data. The Windows TERMINAL:
Transfers: Receive Text File...
dialog box will default to the c:\windows directory and no file.
Create a directory (like \TEMP) (or have an existing one in mind) before starting the export
process.
3.
Model 220 Menu:
7. 5. Maint 5. Export
=================================
| Export Configuration |
| Start RECEIVE TEXT Download |
| to Host on Serial PORT A |
| |
|
<ENTER> to Continue
|
|
< ESC> to Cancel
|
=================================
4.
Windows TERMINAL:
Tra Receive Text File...
.
4.1.
Directories - set directory to desired download directory (C:\TEMP)
4.2.
File Name: - Type desired File Name (for example: export1.txt)
Model 220 Service Manual
A-1
Summary of Contents for 220
Page 1: ...SERVICE MANUAL Model 220 Projector ...
Page 10: ...Safety Information Model 220 Service Manual x ...
Page 14: ...Chapter 1 Introduction 1 4 Model 220 Service Manual ...
Page 119: ...Chapter 4 Maintenance Removal Replacement 4 26 Model 220 Service Manual ...
Page 129: ...Chapter 5 Troubleshooting 5 10 Model 220 Service Manual ...