Installation
Pre-installation Precautions
Do not install in the following types of location:
Where the temperature can be below 14⁰F (-10⁰C) or above 104⁰F (40⁰C)
Where the unit may come into direct contact with water
Where the unit will be in direct or strong sunlight
If there is a lot of condensation in the environment
If there are corrosive, neutral or reductive gases present
Installation location
ADA considerations
Install the unit in a position where it will be easy to use. Note that if the unit is installed too low,
it may get wet while the floor is cleaned.
Ensure the space between the bottom of the unit and the floor is more than 6 inches as the
power operation system is located on the bottom.
It is recommended that there be a minimum of 4 inches should be clearance on either side of
the unit.
Avoid locations where people or a door might damage the unit.
Choose a completely flat wall surface to install the unit.
The Plug and Sockets
The unit must be installed per local electrical code. The unit should be connected directly to a 3-prong
GFI outlet. The outlet should be located at least 8” and no more than 11” away from the unit and never
directly above or below the unit.