Installation 

Pre-installation Precautions 

Do not install in the following types of location: 

 

Where the temperature can be below 14⁰F (-10⁰C) or above 104⁰F (40⁰C) 

 

Where the unit may come into direct contact with water 

 

Where the unit will be in direct or strong sunlight 

 

If there is a lot of condensation in the environment 

 

If there are corrosive, neutral or reductive gases present 

Installation location 

 

ADA considerations 

 

Install the unit in a position where it will be easy to use. Note that if the unit is installed too low, 
it may get wet while the floor is cleaned. 

 

Ensure the space between the bottom of the unit and the floor is more than 6 inches as the 
power operation system is located on the bottom.  

 

It is recommended that there be a minimum of 4 inches should be clearance on either side of 
the unit.  

 

Avoid locations where people or a door might damage the unit. 

 

Choose a completely flat wall surface to install the unit. 
 

The Plug and Sockets 

The unit must be installed per local electrical code.  The unit should be connected directly to a 3-prong 
GFI outlet. The outlet should be located at least 8” and no more than 11” away from the unit and never 
directly above or below the unit. 

 

 

 

Summary of Contents for Filter-Aire 2000

Page 1: ......

Page 2: ...on 7 Trouble shooting 8 Electrical Schematic 8 Use 10 Cleaning Instructions 11 Do not attempt to install the unit yourself unless you are a trained service technician This may affect the safety and fu...

Page 3: ...ifications Rated Voltage A120V Motor Brushless DC motor Input Power 1700W Induction method IR Blocking Wind Velocity 95m s Protection class IPX4 Heating Power 950W Dimensions 11 81 x 8 46 x 27 56 300...

Page 4: ...replace after the power has been turned on Remove from power source and close leakage circuit breaker if the unit is under abnormal status Ensure the unit has a reliable ground connection Do not insta...

Page 5: ...5 Components and Dimensions...

Page 6: ...ist Unit 1 Mounting plate 1 5mm screw plugs 6 6 0 20 x 0 98 self tapping screw 6 User manual including packing list and warranty card 1 Instruction label 1 Installation drilling template 1 Pipe cleani...

Page 7: ...the unit is installed too low it may get wet while the floor is cleaned Ensure the space between the bottom of the unit and the floor is more than 6 inches as the power operation system is located on...

Page 8: ...ean switch the power back on No hot air There is an inbuilt heat sensor in the unit Is there any dirt on the heat sensor Has the fuse inside the terminal box blown Is the ambient temperature higher th...

Page 9: ...d for longer 25 seconds Clear workspace of foreign objects then restart Digital Display Digital changes Countdown is working Display flash Drying time finishes E1 Motor fault it won t operate normally...

Page 10: ...t slowly allowing the water to evaporate Repeat if necessary Pull hands out completely Instruction label Place the instruction sticker in a prominent position The front of the unit or a wall nearby Wh...

Page 11: ...ing the Drain tank Daily It is necessary to regularly empty the drain tank to prevent water from exceeding the full level If the accumulated water is left in the drain tank it may start to smell Gentl...

Page 12: ...inlet panel Pull the HEPA filter out by the handle Clean the HEPA filter Tap it lightly by hand or use a vacuum cleaner You can also use a soft brush to wipe off the dust Re attach to the unit Re ins...

Page 13: ...13 www huebsch services com 3605 White Avenue Eau Claire WI 54703 715 835 3101 2941 Center Court Eagan MN55121 651 686 2320...

Reviews: