![Hubner U-ONE-LWL Operating Instructions Manual Download Page 19](http://html.mh-extra.com/html/hubner/u-one-lwl/u-one-lwl_operating-instructions-manual_2180881019.webp)
UO-EPB-1
Operating and configuration instructions
UO-EPB1_Manual-en_R1
19
Octet
Parameter
Bit no.
Reduced diagnostics
3
Off = 0, on = 1
Reserved
4
---
Software limit switch min.
active
5
Off = 0, on = 1
Software limit switch max.
active
6
Off = 0, on = 1
Octet 27
– 39 active
7
Off = 0, on = 1
27 - 30
Limit switch min.
2
31
– 2
0
31 - 34
Limit switch max.
2
31
– 2
0
35 - 38
Physical measurement
steps
2
31
– 2
0
39
Reserved
0
---
Singleturn/Multiturn
1
Singleturn = 0, Multiturn = 1
Reserved
2
---
Reserved
3
---
Speed unit
5 + 4
00H steps/s
01H steps/100ms
10H steps/10ms
11H RPM
Reserved
6
---
Reserved
7
---
5.1.2.1 Hübner 2.1 and 2.2 (Octet 9.6)
This bit is used to release other module functions available in this profile (in Octet 26).
5.1.2.2 Measurement steps per xxx (Octet 10
–13) + desired measurement steps (Octet 26.0,
26.1)
The bits for the desired measurement steps (Octet 26.0 and 26.1) can be used to save a value in
Octet 10...13 that refers to the following ranges:
Measurement steps per revolution
Measurement steps per max. total resolution
Physical measurement steps
Regarding measurement steps per revolution (Octet 26.0 and 26.1, 00H)
This input is based on one revolution of the basic device, and indicates how many steps it is
divided into. Values up to 4096 can be set. The measurement range of the module is defined
in conjunction with the total resolution of the basic device, which is stored in Octet 14
– 17.
(See total resolution)