UO-EPB-1
Operating and configuration instructions
UO-EPB1_Manual-en_R1
13
4.5 Configure the module
Now, select the profile in which the module should work. Then assign the input and output ad-
dresses and complete configuration. This function can be accessed in the Configure window us-
ing the Parameter button, and offers a simple, easy to understand way to set the parameters.
Configurations must be set in other windows in hexadecimal form, in contrast, and require a pre-
cise understanding of the meaning of the individual bits and bytes.
4.6 Configuring the module
In this example, the Configure window shows the setting options for an absolute encoder config-
ured as HÜBNER 2.0.
NOTE!
If the class 2 function is switched off, then the module will work in HÜBNER 1.0
mode. In this case, only the counting direction can be changed.
The resolution per revolution can be any value between 1 and 4096 and deter-
mines the step length.
The total resolution indicates the number of revolutions the measurement by the
basic device using the selected resolution per revolution lasts until the position
zero is read out again.
Total resolution = resolution per revolution x number of revolutions. The number
of revolutions must be equal to 2
n
with a value between 0 and 12 for n.