INSTALLATION MANUAL
Page 3 of 15
HUBER+SUHNER disclaims any liability resulting from incorrect installation and use, including any damages resulting from the use of tools and
accessories other than the ones recommended herein. Any installation performed by unqualified personnel voids the product warranty provided by
HUBER+SUHNER. All due care and attention must be exercised when performing the installation of these products. For advice concerning the
general handling of these products please contact HUBER+SUHNER.
Step 5
Use the small MLEH installation bracket to fix the housing to the
mast. Mount the MLEH bracket as shown in the picture. The
distance from the top of the housing to the upper clip is around 4
cm (MLEH3/x and MLEH6/6). Make sure the grounding screw is
forward-facing.
The MLEH housing can be pushed into the two clips. This must
be done by muscle power. No tools must be used.
The plastic tabs must be engaged until the last ratchet teeth.
Use the large MLEH installation bracket to fix the housing to the
mast. Mount the MLEH bracket as shown in the picture. The
distance from the top of the housing to the upper clip is around
9.5 cm (MLEH6/12 and MLEH9/x). Make sure the grounding
screw is forward-facing.
The MLEH housing can be pushed into the clip. This must be
done by muscle power. No tools must be used.
The plastic tabs must be engaged over at least 4 ratchet teeth.
Quick hose clamps
H+S item no. 84076411 (pole Ø 30
– 155mm)
H+S item no. 84076412 (pole Ø 60
– 500mm)
One kit consists of two quick hose clamps
Both installation clamps only absorb forces in the
Z and Y direction. Forces in direction X, vertical
forces, must be ensured with cable clamps or
similar mounting material.
Z
X
Y