5
TABLE 1 LED WORKING STATUS INDICATION
TABLE 2 CAPACITY INDICATION INSTRUCTIONS
TABLE 3 LED FLASH INSTRUCTIONS
Note:
can enable or prohibit LED indicator light alarm through the upper machine, the factory default is enabled.
STATUS
NORMAL / ALARM
/ PROTECTION
RUN
ALM
SOC INDICATION LEDS
REMARK
POWER OFF
Dormancy
OFF
OFF
OFF
OFF
OFF
OFF
All off
STANDBY
Normal
Fash 1
OFF
According to the electricity instruction
Standby state
Alarm
Flash 1
Flash 3
Cell low voltage
CHARGE
Normal
Lighting OFF
According to the electricity instruction
(Power level indicates maximum LED
flash 2)
Alarm when
overvoltage light
is off
Alarm
Lighting Flash 3
Overcharge
Protection
Lighting OFF
Lighting Lighting Lighting
Lighting
If there is no
charging the LED
light is in standby
state
Temperature
Over-current
Protection
OFF
Lighting OFF
OFF
OFF
OFF
Stop charging
DISCHARGE
Normal
Flash 3
OFF
According to the electricity instruction.
Alarm
Flash 3
Flash 3
Undervoltage
protection
OFF
OFF
OFF
OFF
OFF
OFF
Stop discharge
Temperature
Overcurrent
Short-circuit
Reverse connection
Failure protection
OFF
Lighting OFF
OFF
OFF
OFF
Stop discharge
FAIL
OFF
Lighting OFF
OFF
OFF
OFF
Stop charging and
discharging.
STATE
CHARGE
DISCHARGE
Capacity Indicator Light
L4
L3
L2
L1
L4
L3
L2
L1
Battery Power (%)
0 ~ 25%
OFF
OFF
OFF
Flash 2
OFF
OFF
OFF
Lighting
25 ~ 50%
OFF
OFF
Flash 2
Lighting OFF
OFF
Lighting Lighting
50 ~ 75%
OFF
Flash 2
Lighting Lighting OFF
Lighting Lighting Lighting
75 ~ 100%
Flash 2
Lighting Lighting Lighting Lighting Lighting Lighting Lighting
FLASH MODE
ON
OFF
FLASH 1
0.25 S
3.75 S
FLASH 2
0.5 S
O.5 S
FLASH 3
0.5 S
1.5 S