Division 2 VoIP Telephones

—Wired and WiFi 

Page 22 of 22

 

P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-501C.docx 

03/20 

 .............................................................................................................................. automatic fault reporting 

Environmental 

Operating temperature ........................................................................... −4 ºF to +140 ºF (−20 ºC to +60 ºC) 

Weather resistance .................................................................................... NEMA Type 4X with door closed 

Humidity ....................................................................................................................... 90% non-condensing 

Mechanical 

Enclosure (gray, yellow, orange, or red) ............................................................................ engineered plastic 

Handset Cord ........................................ G- style handset/Hytrel

® 

or PVC 6-foot extended length (standard) 

Connection ............................................................................................................................. RJ45 receptacle 

Dimensions, outside (VoIP) ......................................... 14.6 H × 10.9 W × 10.5 D in (371 × 276 × 267 mm) 

Dimensions, outside (WiFi) ......................................... 14.8 H × 10.9 W × 10.5 D in (375 × 276 × 267 mm) 

Mounting ...................................................... wall or column, four 0.44 in (11mm) diameter mounting holes 

Shipping weight ..................................................................................................................... 13.5 lb (6.1 kg) 

Net weight .............................................................................................................................. 12.5 lb (5.7 kg) 

Approvals

 

With antenna 

NRTL listed for USA and Canada .............................................. Class I, Groups A, B, C, and D, Division 2 

 

Class II, Groups F & G, Division 2 

 

Class III, Division 2 Hazardous Locations 

 

Temperature code T4 

Outdoor environmental rating ................................................................ Type 3R, Type 4X with door closed 

User Instructions (USA) 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC 
Rules.  These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in 
a commercial environment.  This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used 
in accordance with the instruction manual, may cause harmful interference to radio communications.  Operation of this 
equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the 
interference at his own expense. 

Summary of Contents for GAI-TRONICS Division 2 351-7 7 Series

Page 1: ...6 VoIP 6 VoIP WiFi 6 VoIP Subscriber Tips 7 Operation 7 Handset Receiver Volume Control 7 Model 351 7x7 351 7x8 351 8x7 and 351 8x8 Handset Operation 7 Model 351 7x9 351 7xA 351 8x9 351 8xA Headset Op...

Page 2: ...ontrol 17 Input Contacts 17 Output Contacts 18 Maintenance 18 Status Indication 18 Power 18 Heartbeat 18 Link 18 Speed 18 WiFi Activity WiFi Units Only 18 WiFi Ready WiFi Units Only 18 WiFi Connected...

Page 3: ...er operation is identical to that of a standard analog telephone simply lift the handset and dial the desired telephone number Autodial telephone models dial a preprogrammed number when the handset is...

Page 4: ...Phone with Relay 351 817 Div 2 VoIP WiFi AC Phone 351 827 Div 2 VoIP WiFi DC Phone 351 818 Div 2 VoIP WiFi AC Phone with Relay 351 828 Div 2 VoIP WiFi DC Phone with Relay Handset with Auxiliary Jack...

Page 5: ...et Options Wired 7 WiFi 8 AC 1 DC 2 POE 3 Phone 7 Phone with Relay 8 Phone with Auxiliary Jack 9 Phone with Auxiliary Jack and Relay A Orange 1 Gray 2 Yellow 3 Red 4 None 0 6 foot 1 15 foot 2 6 foot H...

Page 6: ...A Class 0 configurable via web page download or Telnet four configurable auxiliary inputs two configurable dry contact outputs relay units only Hardware Description External Division 2 VoIP telephones...

Page 7: ...et headset adapter PCBA and keypad PCBA are mounted to the front cover Amplifier only versions do not include a keypad PCBA see Figure 3 Model 351 8xx VoIP Telephones The power supply input power term...

Page 8: ...Ethernet network with SIP Session Initiation Protocol server Call capacity is limited by the customer s LAN media capabilities and the services available at each end point VoIPWiFi Two telephones can...

Page 9: ...l to adjust the handset receiver volume The volume decreases from 20 dB to 12 dB to 0 dB and back up to 20 dB of the original signal with each button press The signal level is reset to 20 dB after the...

Page 10: ...lowing precautionary steps to protect the unit during installation Install this unit using appropriate Division 2 wiring methods Run the subscriber line inside conduit to ensure that the unit is vanda...

Page 11: ...tation enclosures is 48 inches 1219 mm to the center of the bottom mounting holes of the enclosure telephone are not supplied with conduit or cable openings 2 Remove the front panel 3 Drill or punch e...

Page 12: ...ws from the power supply cover located in the rear enclosure and remove the power supply cover 2 Connect the incoming power conductors to the 3 point terminal block in the rear enclosure see the Local...

Page 13: ...ductor No 18 AWG is typical Inputs two conductor No 22 AWG is typical Output contacts two conductor No 18 AWG is typical Figure 7 Internal PCBA Connections NetworkCable Connect a Cat5 or better UTP ca...

Page 14: ...t INPUT 1 4 and common COM on terminal block P12 see Table 4 The inputs are configurable Refer to GAI Tronics Pub 42004 548 for configuration instructions see the Reference Documentation section Table...

Page 15: ...otocol between the desired locations before attempting to configure the GAI Tronics VoIP Telephones First Time WiFi Interface Setup wireless telephones only Setup the WiFi interface to configure the t...

Page 16: ...tton the web page will show Set Successfully Restart to use new setting 6 Restart to use the new setting and then click on the STA INTERFACE SETTING selection The STA INTERFACE SETTING web page opens...

Page 17: ...k and click the APPLY button The AP s SSID security mode and encryption type fields will be filled in when the STA interface setting webpage opens again NOTE Manually enter the AP s SSID security mode...

Page 18: ...t WiFi Interface Use this procedure to erase the current WiFi configuration in the telephone and configure the WiFi adapter with the factory default settings 1 Press the RLOAD button for 10 seconds to...

Page 19: ...rowser such as Internet Explorer to view and change settings within a single unit Configuration files are ASCII text files containing configuration options that can be read and edited by a knowledgeab...

Page 20: ...ne Heartbeat The HB LED located on the VoIP PCBA see Figure 13 flashes when communication over the LAN is established Link The LNK LED located on the VoIP PCBA see Figure 13 indicates an active networ...

Page 21: ...return authorization number will be issued if service is required Equipment must be shipped prepaid to GAI Tronics with an RA and a purchase order number Repairs or a replacement will be made in acco...

Page 22: ...e calls Check the connection of the LAN cable Verify that power is applied to the unit Verify the LAN parameters have been configured properly Verify the telephone has been set up on the network no po...

Page 23: ...ing WiFi Network Standards IEEE 802 11b g n Frequency 2 412 GHz to 2 484 GHz Configuration embedded web server configuration file download password protection Handset Audio Analog microphone gain 30 d...

Page 24: ...kg Approvals With antenna NRTL listed for USA and Canada Class I Groups A B C and D Division 2 Class II Groups F G Division 2 Class III Division 2 Hazardous Locations Temperature code T4 Outdoor envir...

Reviews: