Pub. 42004-605L2B
Model 701-804 SmartSeries
®
Handset Station with Auxiliary Jack
Page: 15 of 16
\\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-605l2b.doc
03/04
Specifications
Electrical
Supply voltage .......................................................................... 90 to 140 V ac (120 V ac nominal), 50/60 Hz
Power consumed............................... Zero/maximum signal (12 watts): 15 VA, 10.5 watts/53 VA, 34 watts
Speaker Amplifier
Output .................................................................................. 12 watts minimum, with nominal supply voltage
Output limiter .......................................................................... 13 watts typical (adjustable via configuration)
Frequency response ...........................................................................350 to 6,500 Hz, +0/-3 dB, ref. to 1 kHz
Distortion ............................................................................................ 1% maximum THD @ 1 kHz, 12 watts
SmartVolume™
Monitor range (low gain) ......................................................................................................62 to 100 dB SPL
Offset (above ambient) User Level Adjustment............................................................................... 0 to 49 dB
Minimum User Level Adjustment ................................................................................ Off; 85 to 125 dB SPL
Handset Amplifier
Output ....................................................................................................... 1.5 V
RMS
nominal into 33-ohm load
Frequency Response....................................................................350 to 6,500 Hz, +0 dB, -3 dB ref. to 1 kHz
Distortion ......................................................................................................... 1.5% maximum THD @ 1 kHz
Mechanical
Dimensions ................................................8.12 H
×
8.12 W
×
6.12 D inches (206
×
206
×
155 mm), overall
Environmental
Temperature range..............................................-22 °F to +158°F (-30 °C to +70 °C), operating and storage
Humidity..........................................................................................................................95%, non-condensing
Approvals
NRTL Listed for USA and Canada........................................................... Class I, Div. 2, Groups A, B, C, D;
when used with listed GAI-Tronics Model 702 and 703 Series Enclosures
Class I, Div. 2, Groups A, B, C, D;
Class II, Div. 2, Groups F, G; Class III, Div. 2
when used with listed GAI-Tronics Model 732, 733, 7325, and 7335 Series Enclosures