background image

INSTALLING HOOK/LOOP MOUNT (See Figure 1, 2, & 3):

NOTE: Cord and Hook/Loop ordered as CxHLPx
(Plug optional and ordered separately)

1. Insert end of Power Cord (A) through Hook/Loop (B). Supply cord is to be rated for a minimum of 90OC 16/3 SEOW-A/STOOW.
2. Insert end of Power Cord through the Cord Grip/Gotcha-ring (D),Rubber Bushing (E) and Washer (F). Note that the Rubber
    Bushing is placed between the Cord Grip and Washer. Part of the cord jacket should extend through Bushing (E) and Washer
    (F).
3. Insert the Power Cord through the Yoke Assy Crossmember (C) and into the Wiring Box ¾ Conduit hole, allowing the Washer   
    (F), Bushing (E) to “seat” inside. The Cord Grip (D) remains in place at the Hook/Loop.
4. Apply Teflon tape to the male (external) conduit thread of the Hook (A).
5. Thread the Hook (A) into the ¾” NPT Conduit Box (C). Use a wrench over the hex shape on the hook casting to tighten it in
    place.
    CAUTION: Do not twist the hook by using a screwdriver blade – too much force could break the hook.
6. Connect cord wires to the fixture AC Power Input Jumper Cord Ass’y, already factory installed into J-box, with approved wire
    nuts. See wiring diagram for reference (page 3 and figure 6). Wires and wire nuts can now be pushed back into the
    fixture/driver housing. Ensure grounding wires within wiring Box are secure.
7. Close out Wiring Box (G) using Cover, Cover Gasket, and Screws provided in hardware kit.
8. Mount wired Yoke Assembly (H) onto fixture rails using 5/16” Screw (J) provided in hardware kit into each pair of Slide Nut (K)
    already inserted into the rail. Position the mounted Yoke Ass’y according to the centering illustration on page 10. Fine tuning   
    of the final Yoke Ass’y position on the rail may be required to achieve final balance and alignment.
9. Tighten the Yoke Ass’y mounting screws to torque noted in Fig. 3.
10. Tighten Set Screw (F) to secure hook from loosening.
11. Secure Closure Backet (M) with Screw (N) provided.
12. Install lens option onto each Lightbar, see Figure 9. If wireguard was ordered, lenses will ship installed on fixture.
13. Complete electrical connection by installing AC Input Jumper Cord connector into AC Panel as shown in Figure 3.

INSTALLATION INSTRUCTIONS

Hubbell Lighting, Inc.                                                                                                                            Doc. No. 93062486

A subsidiary of Hubbell Incorporated                                                                                                            Revision  A

701 Millennium Drive • Greenville, SC  29607                                                                                Phone (864) 678-1000

Industrial Lighting

®

FIGURE 1

FIGURA 1

FIGURE 3

FIGURA 3

FIGURE 2

FIGURA 2

PAGE 1

WIRING BOX

3/4" OUTLETS

(G)

5/16 MNTG SCREW (J)

INTO RAIL SLIDE NUT (K)

TORQUE: 120 IN-LB

HHH (MODULAR HIGHBAY) 

INSTALLATION INSTRUCTIONS 

SEE WARNINGS ON CARTON 

WARNINGS: 

 

Observe all precautions usually followed when dealing with high 

voltage equipment when installing or servicing this light fixture. 

 

Disconnect power before installing or servicing. 

 

The product must be installed in accordance with the applicable 

installation code by a person familiar with the construction and 

operation of the product and the hazards involved. 

 

Protect all wiring connections with approved insulators rated 

600V, 150

O

C.

 

Line voltage must be 120V – 277V to match Fixture voltage 

requirement. 

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

 

Upon receipt of this Fixture, thoroughly inspect it for any damage.  

 If any is found, the carrier should be notified and held 

accountable. 

INSTALLING HOOK/LOOP MOUNT (See Figure 1, 2, & 3): 

NOTE: Cord and Hook/Loop ordered as CxHLPx  
(Plug optional and ordered separately) 

1.

  Insert end of Power Cord (A) through Hook/Loop (B). Supply cord 

is to be rated for a minimum of 90

O

C 16/3 SEOW-A/STOOW. 

2.

  Insert end of Power Cord through the Cord Grip/Gotcha-ring (D), 

Rubber Bushing (E) and Washer (F).  Note that the Rubber 

Bushing is placed between the Cord Grip and Washer.  Part of 

the cord jacket should extend through Bushing (E) and Washer 

(F). 

3.

  Insert the Power Cord through the Yoke Assy Crossmember (C) 

and into the Wiring Box ¾ Conduit hole, allowing the Washer (F), 

Bushing (E) to “seat” inside. The Cord Grip (D) remains in place 

at the Hook/Loop. 

4.

  Apply Teflon tape to the male (external) conduit thread of the 

Hook (A). 

5.

  Thread the Hook (A) into the ¾” NPT Conduit Box (C). Use a 

wrench over the hex shape on the hook casting to tighten it in 

place. 

CAUTION:

 Do not twist the hook by using a screwdriver blade – 

too much force could break the hook. 

6.

  Connect cord wires to the fixture AC Power Input Jumper Cord 

Ass’y, already factory installed into J-box, with approved wire 

nuts. See wiring diagram for reference (page 3 and figure 6). 

Wires and wire nuts can now be pushed back into the 

fixture/driver housing. Ensure grounding wires within wiring Box 

are secure. 

7.

  Close out Wiring Box (G) using Cover, Cover Gasket, and Screws 

provided in hardware kit. 

8.

  Mount wired Yoke Assembly (H) onto fixture rails using 5/16” 

Screw (J) provided in hardware kit into each pair of Slide Nut (K) 

already inserted into the rail. Position the mounted Yoke Ass’y 

according to the centering illustration on page 10. Fine tuning of 

the final Yoke Ass’y position on the rail may be required to 

achieve final balance and alignment. 

9.

  Tighten the Yoke Ass’y mounting screws to torque noted in Fig. 3. 

10.

  Tighten Set Screw (F) to secure hook from loosening. 

11.

  Secure Closure Backet (M) with Screw (N) provided. 

12.

  Install lens option onto each Lightbar, see Figure 9. If wireguard 

was ordered, lenses will ship installed on fixture. 

13.

  Complete electrical connection by installing AC Input Jumper 

Cord connector into AC Panel as shown in Figure 3. 

CLOSURE

BRACKET (M)

RETAINING 

SCREW (N)

AFTER WIRING

ASSEMBLE YOKE

TO FIXTURE USING

RAIL MOUNTING

HARDWARE KIT

- SEE FIG. 3

D

E

F

A

B

YOKE

CROSSMEMBER

C

COMPLETE

YOKE ASS'Y

(H)

(CORDSETS

NOT SHOWN)

FIGURE 1a.

FIGURA 1a.

PLUG

(OPTION

 

AL)

CORD

ROUTE INTO

J-BOX WIRE TO

AC INPUT JUMPER

L

M

N

Hubbell Lighting, Inc.                                                                                                                            Doc. No. 93062486

A subsidiary of Hubbell Incorporated                                                                                                            Revision  A

701 Millennium Drive • Greenville, SC  29607                                                                                Phone (864) 678-1000

Industrial Lighting

®

FIGURE 1

FIGURA 1

FIGURE 3

FIGURA 3

FIGURE 2

FIGURA 2

PAGE 1

WIRING BOX

3/4" OUTLETS

(G)

5/16 MNTG SCREW (J)

INTO RAIL SLIDE NUT (K)

TORQUE: 120 IN-LB

HHH (MODULAR HIGHBAY) 

INSTALLATION INSTRUCTIONS 

SEE WARNINGS ON CARTON 

WARNINGS: 

 

Observe all precautions usually followed when dealing with high 

voltage equipment when installing or servicing this light fixture. 

 

Disconnect power before installing or servicing. 

 

The product must be installed in accordance with the applicable 

installation code by a person familiar with the construction and 

operation of the product and the hazards involved. 

 

Protect all wiring connections with approved insulators rated 

600V, 150

O

C.

 

Line voltage must be 120V – 277V to match Fixture voltage 

requirement. 

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

 

Upon receipt of this Fixture, thoroughly inspect it for any damage.  

 If any is found, the carrier should be notified and held 

accountable. 

INSTALLING HOOK/LOOP MOUNT (See Figure 1, 2, & 3): 

NOTE: Cord and Hook/Loop ordered as CxHLPx  
(Plug optional and ordered separately) 

1.

  Insert end of Power Cord (A) through Hook/Loop (B). Supply cord 

is to be rated for a minimum of 90

O

C 16/3 SEOW-A/STOOW. 

2.

  Insert end of Power Cord through the Cord Grip/Gotcha-ring (D), 

Rubber Bushing (E) and Washer (F).  Note that the Rubber 

Bushing is placed between the Cord Grip and Washer.  Part of 

the cord jacket should extend through Bushing (E) and Washer 

(F). 

3.

  Insert the Power Cord through the Yoke Assy Crossmember (C) 

and into the Wiring Box ¾ Conduit hole, allowing the Washer (F), 

Bushing (E) to “seat” inside. The Cord Grip (D) remains in place 

at the Hook/Loop. 

4.

  Apply Teflon tape to the male (external) conduit thread of the 

Hook (A). 

5.

  Thread the Hook (A) into the ¾” NPT Conduit Box (C). Use a 

wrench over the hex shape on the hook casting to tighten it in 

place. 

CAUTION:

 Do not twist the hook by using a screwdriver blade – 

too much force could break the hook. 

6.

  Connect cord wires to the fixture AC Power Input Jumper Cord 

Ass’y, already factory installed into J-box, with approved wire 

nuts. See wiring diagram for reference (page 3 and figure 6). 

Wires and wire nuts can now be pushed back into the 

fixture/driver housing. Ensure grounding wires within wiring Box 

are secure. 

7.

  Close out Wiring Box (G) using Cover, Cover Gasket, and Screws 

provided in hardware kit. 

8.

  Mount wired Yoke Assembly (H) onto fixture rails using 5/16” 

Screw (J) provided in hardware kit into each pair of Slide Nut (K) 

already inserted into the rail. Position the mounted Yoke Ass’y 

according to the centering illustration on page 10. Fine tuning of 

the final Yoke Ass’y position on the rail may be required to 

achieve final balance and alignment. 

9.

  Tighten the Yoke Ass’y mounting screws to torque noted in Fig. 3. 

10.

  Tighten Set Screw (F) to secure hook from loosening. 

11.

  Secure Closure Backet (M) with Screw (N) provided. 

12.

  Install lens option onto each Lightbar, see Figure 9. If wireguard 

was ordered, lenses will ship installed on fixture. 

13.

  Complete electrical connection by installing AC Input Jumper 

Cord connector into AC Panel as shown in Figure 3. 

CLOSURE

BRACKET (M)

RETAINING 

SCREW (N)

AFTER WIRING

ASSEMBLE YOKE

TO FIXTURE USING

RAIL MOUNTING

HARDWARE KIT

- SEE FIG. 3

D

E

F

A

B

YOKE

CROSSMEMBER

C

COMPLETE

YOKE ASS'Y

(H)

(CORDSETS

NOT SHOWN)

FIGURE 1a.

FIGURA 1a.

PLUG

(OPTION

 

AL)

CORD

ROUTE INTO

J-BOX WIRE TO

AC INPUT JUMPER

L

M

N

Hubbell Lighting, Inc.                                                                                                                            Doc. No. 93062486

A subsidiary of Hubbell Incorporated                                                                                                            Revision  A

701 Millennium Drive • Greenville, SC  29607                                                                                Phone (864) 678-1000

Industrial Lighting

®

FIGURE 1

FIGURA 1

FIGURE 3

FIGURA 3

FIGURE 2

FIGURA 2

PAGE 1

WIRING BOX

3/4" OUTLETS

(G)

5/16 MNTG SCREW (J)

INTO RAIL SLIDE NUT (K)

TORQUE: 120 IN-LB

HHH (MODULAR HIGHBAY) 

INSTALLATION INSTRUCTIONS 

SEE WARNINGS ON CARTON 

WARNINGS: 

 

Observe all precautions usually followed when dealing with high 

voltage equipment when installing or servicing this light fixture. 

 

Disconnect power before installing or servicing. 

 

The product must be installed in accordance with the applicable 

installation code by a person familiar with the construction and 

operation of the product and the hazards involved. 

 

Protect all wiring connections with approved insulators rated 

600V, 150

O

C.

 

Line voltage must be 120V – 277V to match Fixture voltage 

requirement. 

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

 

Upon receipt of this Fixture, thoroughly inspect it for any damage.  

 If any is found, the carrier should be notified and held 

accountable. 

INSTALLING HOOK/LOOP MOUNT (See Figure 1, 2, & 3): 

NOTE: Cord and Hook/Loop ordered as CxHLPx  
(Plug optional and ordered separately) 

1.

  Insert end of Power Cord (A) through Hook/Loop (B). Supply cord 

is to be rated for a minimum of 90

O

C 16/3 SEOW-A/STOOW. 

2.

  Insert end of Power Cord through the Cord Grip/Gotcha-ring (D), 

Rubber Bushing (E) and Washer (F).  Note that the Rubber 

Bushing is placed between the Cord Grip and Washer.  Part of 

the cord jacket should extend through Bushing (E) and Washer 

(F). 

3.

  Insert the Power Cord through the Yoke Assy Crossmember (C) 

and into the Wiring Box ¾ Conduit hole, allowing the Washer (F), 

Bushing (E) to “seat” inside. The Cord Grip (D) remains in place 

at the Hook/Loop. 

4.

  Apply Teflon tape to the male (external) conduit thread of the 

Hook (A). 

5.

  Thread the Hook (A) into the ¾” NPT Conduit Box (C). Use a 

wrench over the hex shape on the hook casting to tighten it in 

place. 

CAUTION:

 Do not twist the hook by using a screwdriver blade – 

too much force could break the hook. 

6.

  Connect cord wires to the fixture AC Power Input Jumper Cord 

Ass’y, already factory installed into J-box, with approved wire 

nuts. See wiring diagram for reference (page 3 and figure 6). 

Wires and wire nuts can now be pushed back into the 

fixture/driver housing. Ensure grounding wires within wiring Box 

are secure. 

7.

  Close out Wiring Box (G) using Cover, Cover Gasket, and Screws 

provided in hardware kit. 

8.

  Mount wired Yoke Assembly (H) onto fixture rails using 5/16” 

Screw (J) provided in hardware kit into each pair of Slide Nut (K) 

already inserted into the rail. Position the mounted Yoke Ass’y 

according to the centering illustration on page 10. Fine tuning of 

the final Yoke Ass’y position on the rail may be required to 

achieve final balance and alignment. 

9.

  Tighten the Yoke Ass’y mounting screws to torque noted in Fig. 3. 

10.

  Tighten Set Screw (F) to secure hook from loosening. 

11.

  Secure Closure Backet (M) with Screw (N) provided. 

12.

  Install lens option onto each Lightbar, see Figure 9. If wireguard 

was ordered, lenses will ship installed on fixture. 

13.

  Complete electrical connection by installing AC Input Jumper 

Cord connector into AC Panel as shown in Figure 3. 

CLOSURE

BRACKET (M)

RETAINING 

SCREW (N)

AFTER WIRING

ASSEMBLE YOKE

TO FIXTURE USING

RAIL MOUNTING

HARDWARE KIT

- SEE FIG. 3

D

E

F

A

B

YOKE

CROSSMEMBER

C

COMPLETE

YOKE ASS'Y

(H)

(CORDSETS

NOT SHOWN)

FIGURE 1a.

FIGURA 1a.

PLUG

(OPTION

 

AL)

CORD

ROUTE INTO

J-BOX WIRE TO

AC INPUT JUMPER

L

M

N

Summary of Contents for TRIPLE H

Page 1: ...n familiar with the construction and operation of the product and the hazards involved Protect all wiring connections with approved insulators rated 600V 150 C Line voltage must be 120V 277V to match...

Page 2: ...hook casting to tighten it in place CAUTION Do not twist the hook by using a screwdriver blade too much force could break the hook 6 Connect cord wires to the fixture AC Power Input Jumper Cord Ass y...

Page 3: ...IGURE 5 FIGURA 5 FIGURE 6 FIGURA 6 PAGE 2 WIRING BOX COVER 8 32 SCREWS LOCKNUT Q YOKE ASSEMBLY H 3 4 CONDUIT INLET INTO J BOX SEAL WITH RTV AFTER INSTALL PENDANT 3 4 RIGID CONDUIT P HHH MODULAR HIGHBA...

Page 4: ...igure 7 and 8 WARNING NOTICE AIRCRAFT CABLE KIT TYPE SHIPPED WITH YOUR ORDER 2mm KIT FOR LOWBAY SERIES ONLY 3mm KIT FOR HIGHBAY SERIES ONLY 1 Install AC Mounting Bracket R onto each corner of the rail...

Page 5: ...TION INSTRUCTIONS Hubbell Lighting Inc Doc No 93062486 A subsidiary of Hubbell Incorporated Revision C 701 Millennium Drive Greenville SC 29607 Phone 864 678 1000 Industrial Lighting PAGE 1 SEE TABLE...

Page 6: ...E RED BLUE RED BLUE WHITE BLACK WHITE BLACK R E D W H T B L K R E D W H T B L K R E D W H T B L K GREEN BLACK WHITE Hubbell Lighting Inc A subsidiary of Hubbell Incorporated 701 Millennium Drive Green...

Page 7: ...HITE BLACK WHITE BLACK R E D W H T B L K R E D W H T B L K R E D W H T B L K GREEN BLACK WHITE Hubbell Lighting Inc A subsidiary of Hubbell Incorporated 701 Millennium Drive Greenville SC 29607 Indust...

Page 8: ...l Lighting PAGE 9 HHH WIRING DIAGRAMS Doc No 93062486 Revision A Phone 864 678 1000 GROUND GREEN LINE HOT BLACK COMMON NEUTRAL WHITE BLACK WHITE RED FUSING FUSING SINGLE FUSE OPTION DOUBLE FUSE OPTION...

Reviews: