Safe Use Items

Design and manufacture of the instrument and testing achieves IEC61010 safety

standards (electronic measuring product safety requirements), this manual including the

safety of the instrument use and ensure the safety of equipment state, users must follow

the warnings and safety regulations Please read the following instructions before use.

Warning

● Instrument output voltage, before use, read and understand the instructions of

operational guidelines.

● Please take manual save you to check at any time.

● Must be instructed to use the instrument.

● Understand and comply with the safety operating instructions.

Must strictly abide by the above instructions.

If you don't comply, measurement may cause personal injury and equipment damage.

Dangerous (for improper operation can lead to serious or fatal damage)

● Before use, please wear insulated gloves.

● Please do not over AC/DC600V measurement circuit.

● Please do not test in flammable places, spark could cause an explosion.

● please do not hand wet or damp operators in instrument surface operation.

● Please don't charged the connection test line low.

● Low in the measurement, or do not touch the circuit being measured immediately after

the test, may result in electric shock accidents.

● Low test line or port found easy to damage the insulation properties of dirt or carbon

please stop test.

Warning

(for improper operation exists the possibility of a severe or fatal

damage)

● If the instrument is abnormal, please stop using it. For example: instrument damage or

bare metal parts.

Summary of Contents for HZJY-5K-I

Page 1: ...HZJY 5K I Insulation Resistance Tester Huazheng Electric Manufacturing Baoding Co Ltd...

Page 2: ...l and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this instr...

Page 3: ...Contents I Safe Use Items 1 II Feature 2 III Specification Parameter 3 IV Introduction Of Instrument 4 V Instrument Using 7 VI Packing List 8...

Page 4: ...tions If you don t comply measurement may cause personal injury and equipment damage Dangerous for improper operation can lead to serious or fatal damage Before use please wear insulated gloves Please...

Page 5: ...ltage insulation resistance tester with 5 range 500V 1000V 2500V 5000V test up to 5T Strict accordance with the safety standards for design Insulation resistance range 5T 5 kv Short circuit current ca...

Page 6: ...our size L x W x H 26cm x 20cm x 16cm weight 3kg Test voltage accuracy the nominal value 100 to 110 Voltage measurement accuracy 5 3V Current test range 10mA current measure precision 5 0 2nA short ci...

Page 7: ...g 2 AC ON 3 Test Port E G L 4 LCD display 5 Key Key and function Key numbered from left to right the first for a total of five off down the power Key key number Description 1 Press the switch on butto...

Page 8: ...pass filter applicable to most situations 2 software Low pass filter High resistance greater than 100G recommended choose 3 hardware software low pass filter high resistance is greater than 1T recomm...

Page 9: ...OK Confirm to enter the current menu function or to determine the current Settings and exit Help menu system HELP Record the serial number of product production date version information Insulation tes...

Page 10: ...e polarization index after 600 seconds Polarization index calculation method PI R600 R60 test connection points for attention 1 Tested to confirm product safety grounding try not charged 2 Confirm the...

Page 11: ...8 VI Packing List No Item Qty 1 Main engine 1 2 Power line 1 3 Red test line 1 4 Black test line 1 5 Green test line 1...

Reviews: