Dear user:

Thank you for choosing HZ-5300 Contact Resistance Tester.

We hope that this instrument can make your work easier and more

enjoyable, so that you can get the feeling of office automation in the test

and analysis work.

Before using the instrument, please read this manual, and operate and

maintain the instrument according to the manual to prolong its service life.

"Just a light press, the test will be completed automatically" is the

operating characteristics of this instrument.

If you are satisfied with this instrument, please tell your colleagues;

if you are not satisfied with this instrument, please call (0312) 6775656 to

tell you to serve you at all times-Baoding Huazheng Electric Manufacturing

Co., Ltd., our company will definitely make you satisfied !

Summary of Contents for HZ-5300

Page 1: ...HZ 5300 Contact Resistance Tester User Manual Huazheng Electric Manufacturing Baoding Co Ltd...

Page 2: ...and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this instrum...

Page 3: ...what will you notice before testing III Brief Introduction Working theory V Technical parameter VI PLC interface VII Operation Instructions and Procedures VIII Applying Illustration IX Calibration X...

Page 4: ...artments Claim The output current and measuring resistance are simultaneously output on the 65K true color LCD and the measurement results can be voltage output or stored in a USB flash drive The powe...

Page 5: ...lution min 0 1 Accuracy 0 5 2 words Power 1000W Working mode continuous measurement Power supply AC220V 10 50HZ Operating temperature 0 40 Relative humidity less than or equal to 90 without condensati...

Page 6: ...Press this key to select various settings of the instrument and the data can be printed after measurement 9 Circulation key main menu cycle selection key or U disk storage 10 Confirm key Press the con...

Page 7: ...ropriate measurement time and measurement current press the start button to start the current the screen displays charging a few seconds later it displays testing and a few seconds later it displays t...

Page 8: ...to move the cursor to the clock to modify press the select key to enter the interface as shown in Figure 4 Figure 4 Press the cycle key to move the cursor between each date data press the select key...

Page 9: ...uld be removed first 1 Wiring method As shown in Figure 6 connect the dedicated test wire to the corresponding I and I terminals according to the color red to red black to black and tighten the thin p...

Page 10: ...sed to measure loop resistance and it is not allowed to measure inductive loops After sales service The instrument will be repaired and replaced free of charge for product quality problems within one...