background image

2

reach 2000μΩ.

Has the open circuit protection, overheating protection and so on perfect

protection function.

5. 6 inch super-industrial-grade high-brightness color LCD screen, in strong

sunlight display is still clearly visible.

Equipped with external printer, easy to print data.

With native storage and USB disk storage, easy to save data

.

IV.Technical Index

Measuring Range

Output Current 100A

80A

50A

30A

Measuring
Range

100A 0~2000µΩ
80A

0~5mΩ

50A

0~10mΩ

30A

0~20mΩ

Technical Index

Accuracy

±

Reading×0.5%+1µΩ

Resolution
Ratio

0.1µΩ

Display Digit

Four and a half

Test Power
Supply

Constant current limit voltage

about 2V

Input Voltage

Maximum 5V

Measuring
Time

Quick

10~60 seconds optional

Testing Times

More than 600 times

full charge, fast measurement mode

Test Line

Resistance less than 10mΩ

Conditions Of Use and Shape

working Power
Supply

Built-in lithium battery or external charger

Charger input 100~240VAC

50HZ/60HZ

Charging
Voltage

12.6V

Charging
Current

≤3A

Charging Time

Abour 3 hrs

Auto Shut Off

5 minutes automatic shutdown without
operation

Instrument
Weight

1.7kg

exclude

test lines

Instrument
Dimension

246mm

L

×156mm

W

×62mm

H

Environment
Temperature

-10

~50

Relative
Humidity

≤90%

no dew

Summary of Contents for HZ-5100S

Page 1: ...HZ 5100S Portable Contact Resistance Tester Huazheng Electric Manufacturing Baoding Co Ltd...

Page 2: ...ual and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this ins...

Page 3: ...verely shorten the battery life and even make the battery scrap When the instrument is short of power the power supply should be switched off and charged immediately Avoid battery failure due to exces...

Page 4: ......

Page 5: ...s I Introduction 1 II Packaging Content 1 III Features 1 IV Technical Index 2 V Adjust The Wristband 3 VI Battery Charging 3 VII Tilt Hand held Tester 3 VIII Product Appearance 4 IX Operation Instruct...

Page 6: ......

Page 7: ...eight company or our salesman immediately Please check if you have received the following items in the product package 1 Hand held Circuit resistance tester 1 sets of test lines red and black each 1 c...

Page 8: ...5 1 Resolution Ratio 0 1 Display Digit Four and a half Test Power Supply Constant current limit voltage about 2V Input Voltage Maximum 5V Measuring Time Quick 10 60 seconds optional Testing Times Mor...

Page 9: ...evice please use the charger attached to it to charge the battery for at least 3 hours and continue to use the hand held tester when charging When the battery is fully charged the charger light change...

Page 10: ...enu and test results Button Operate instruments is the up and down key select to move or modify data is the left and right key select to move or modify data Enter key confirm the current operation Can...

Page 11: ...he instrument tighten the current connection pole and firmly clamp the test clamp to reduce the lead resistance and save the battery power If the test line contacts badly and the current cannot reach...

Page 12: ...tus This icon is displayed when you insert a USB drive This icon is displayed when the printer is inserted This icon is displayed when a Bluetooth device is connected This icon is displayed when stori...

Page 13: ...on 1 Parameter setting area Select these parameters through the key When these parameters are selected press the key to modify the corresponding parameters To modify the number press the Enter key to...

Page 14: ...number of this test 2 The main display area shows the measured circuit resistance The minimum resolution is 0 1 the display digit is 4 5 bits and the unit m is switched automatically No Instruction 3...

Page 15: ...urrent setting parameters Print the current test results by connecting the external printer Save the current test results to the local computer or save it to the external USB disk Tip the data saved t...