2

Data storage

1000 groups

Working

environment

Ambient temperature: 0

℃ ~

40

Relative humidity: <90%RH, no
condensation

Power supply

Built-in lithium battery

AC

220V±10V

50Hz±1 Hz

Fuse 2A

Max power

consumption

100W

Dimensions

360*290*170

mm

Weight

Instrument

4.85Kg Wire box:9.5Kg

III.Main features

1. The whole machine is controlled by high-speed single-chip microcomputer, with high

degree of automation and easy operation.

2. The instrument adopts brand new power supply technology, with many current gears

and wide measuring range.

3. Intelligent power management technology, the instrument always works in the minimum

power state, effectively reducing the internal heating of the instrument and saving energy.

4. Seven-inch high-brightness touch color LCD, clear display under strong light, full touch

screen operation

5. The instrument has its own power-down storage, which can store 1000 sets of test data,

which can be consulted at any time

6. The instrument comes with lithium battery, built-in charger, integrated design, easy to

operate

IV.System introduction

The panel of the instrument is shown below

Summary of Contents for HZ-3510

Page 1: ...HZ 3510 Grounding Continuity Tester User Manual Huazheng Electric Manufacturing Baoding Co Ltd...

Page 2: ...and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this instrum...

Page 3: ...nd characteristics of the instrument 1 II Main Specifications 1 III Main features 2 IV System introduction 2 V Test and operation method 3 VI Four terminal wiring method 6 VII Precautions 6 VIII After...

Page 4: ...Prevent Major Accidents in Electric Power Production it is clearly stated that the conduction test of the down conductor of the grounding device should be carried out once a year The HZ 3510 groundin...

Page 5: ...d new power supply technology with many current gears and wide measuring range 3 Intelligent power management technology the instrument always works in the minimum power state effectively reducing the...

Page 6: ...harger Charging indication The green indicator light indicates the charging is complete and the red indicator indicates the charging process V Test and operation method Take out and connect the specia...

Page 7: ...e test it will display Charging please wait to enter the test state a few seconds later the test result will be displayed as shown in Figure 3 Figure 3 After the test result is displayed click local s...

Page 8: ...cursor to the clock modification press the select key to enter the clock modification interface As shown in Figure 5 Figure 5 Click to set the date and time 5 Click System Settings in Figure 1 to ent...

Page 9: ...ur terminal wiring method As shown in Figure 7 Figure 7 VII Precautions 1 When selecting the current please refer to the range in the technical index column When the range is exceeded the instrument i...

Page 10: ...aired free of charge for product quality problems belonging to the company within one year from the date of purchase and lifetime warranty and technical services will be provided If you find that the...

Reviews: