background image

9

No.

Instruction

1

First-level operation directory, through the “↑↓” key to select these
functions, when these functions are selected, press the “←”→”" key
to select the parameters of the corresponding functions.

Tip: The cursor can quickly jump to the button by pressing the

"Enter" button under the first-level operation directory at “Start Test”.

Testing

temperature

The current temperature of the tested product is set from -99 to +99
C. The device can monitor the samples in real time through an
external wireless temperature probe.

No.

Instruction

Testing

temperature

Internal oil temperature can also be manually set temperature. When
the external wireless temperature probe is connected, it can not be
manually set, and the probe must be closed before setting it
manually.

Convert

temperature

Setting the measured resistance value needs to be converted to the
temperature value. The converted temperature value is 0

℃ ~

+255

, which is related to the accuracy of the converted resistance

value.

Winding

materials

The winding materials of the test products can be selected as copper
and aluminum. The winding materials are related to the conversion
coefficient used in the conversion value of the resistance.

Testing current

Select the test current gear. Choose 1mA, 10mA, 0.1a, 1A, 5A, 10A
and automatic.

2

The secondary operation directory corresponds to the setting
parameters of the primary operation directory, and the parameters
are modified by “←”→” key to move the cursor and “↑↓” key.

Tip: the cursor in the second level of operation directory, you can

press the "Enter" or "Cancel" key to jump the cursor to the first level
of operation directory.

No.

Instruction

3

The range of current selected for testing.

4

When the cursor is here, press “Enter” to start the measurement.

Summary of Contents for HZ-3110E-I

Page 1: ...HZ 3110E I Portable DC Winding Resistance Tester Huazheng Electric Manufacturing Baoding Co Ltd...

Page 2: ...manual and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this...

Page 3: ...aging Content 2 IV Functional Characteristics 3 V Technical Indicators 3 VI Adjust The Wristband 4 VII Battery Charging 4 VIII Tilt Hand held Tester 4 IX Product Appearance 5 X Operation Instructions...

Page 4: ...nt or battery fails please return to the factory II Introduction Portable DC Winding Resistance Tester is an innovative product with compact size hand held operation more portable and easy to carry Th...

Page 5: ...ected which is convenient and fast Wide range and high accuracy 500u 50K It has the function of resistance temperature conversion and can be equipped with wireless temperature measurement module which...

Page 6: ...90 No dew VI Adjust The Wristband For better grip strip the belt and adjust the adhesive tape as shown in the following figure VII Battery Charging When the battery is low after long storage or befor...

Page 7: ...5 Lift the tilt seat and pull outward IX Product Appearance Top view...

Page 8: ...surement signal reception Display 5 6 inch large industrial high brightness color LCD screen display operation menu and test results button Operate instruments is the up and down key select to move or...

Page 9: ...ischarge protection when the instrument is low power the charger can be plugged in to charge and the instrument can be used normally in the charging process Instructions for use of printer The key of...

Page 10: ...ress Enter to enter the corresponding menu DC resistance test function can measure transformer mutual inductor reactor and other inductive test products and copper bars conductors switch contacts and...

Page 11: ...emperature Setting the measured resistance value needs to be converted to the temperature value The converted temperature value is 0 255 which is related to the accuracy of the converted resistance va...

Page 12: ...on and press the Cancel button to return to the previous screen Retest according to the current settings parameters Print the current test results by connecting the external printer Save the current t...

Page 13: ...11 In the process of testing transformers the unmeasured side winding must be opened XII Packing List No Item Qty 1 Main engine 1 2 Power line 1 3 Red test line 1 4 Black test line 1...