5

the crocodile through the voltage test line, and the other end is connected to the

instrument 6-core air seat (voltage input end). Or access through a voltage extension

cord.

ii.

Wireless measurement method: the voltage input is connected to the PT secondary

terminal through the alligator clip of the voltage test line, and the other end is connected to

the wireless module 6-pin aviation seat (voltage input terminal

.

iii.

iii. No PT measurement method: No voltage signal is connected, only current signal is

connected.

Regardless of the measurement method, the current wiring method is the same. The

alligator clips of the ABC three-phase current wiring are connected in series with the zinc

oxide to be measured.

c) PT transformation ratio: PT quadratic method can set a voltage transformation ratio

Ku, which is "multiplied" by the reference voltage amplitude input by the instrument, and

affects the voltage-related data. Set appropriate PT ratio in wired or wireless mode, which

can directly display the bus voltage.

After the data is stable, press the lock screen button and the test ends.

Parameter Description

Here, a single-phase full data screen is used to illustrate the

meaning of the data.

Primary voltage

According to the bus PT transformation ratio, it is the bus voltage.

Secondary voltage

The actual measured voltage value.

Ix

Full current effective value

Irp

Resistive current peak

Ir1p

The fundamental peak value of the resistive current.Ir1p = Ix1p sinΦ

Ic1p

The peak value of the capacitive current fundamental wave.Ic1p = Ix1p cosΦ

P1

Fundamental power consumption.P1 is equal to the product of the effective value of

the fundamental wave of resistive current and the effective value of the fundamental wave

of voltage.

Ir3p

Ir5p

Ir7p

3rd, 5th, 7th harmonic peak value of resistive current.

Φ

The current leads the voltage angle, which already contains the compensation angle

Summary of Contents for HZ-20A

Page 1: ...HZ 20A Wireless Zinc Oxide Arrester Tester Huazheng Electric Manufacturing Baoding Co Ltd...

Page 2: ...ual and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this ins...

Page 3: ...Content I OVERVIEW 1 II MAIN TECHNICAL INDEX 1 III MAIN FUNCTIONS AND FEATURES 1 IV METHOD OF OPERATION 2 V PRECAUTIONS 8 VI AFTER SALES SERVICE 9 VII PACKING LIST 10...

Page 4: ...display English menu prompt operation so that the human machine exchange function is stronger while providing on site waveform display This instrument has the characteristics of simple wiring high me...

Page 5: ...the capacity is limited by the size of U disk 7 The voltage test line of the instrument is equipped with insurance to prevent misconnection The voltage and current plug of the instrument has the func...

Page 6: ...ine and turning on the power of the instrument the display interface is shown below 2 Three phase test setting interface Press the three phase test to enter the three phase parameter setting interface...

Page 7: ...s For single phase test the file display mode is the same as that for three phase test 3 Parameter description a Name For storage or printing it is recommended to set before measurement b Measurement...

Page 8: ...oltage amplitude input by the instrument and affects the voltage related data Set appropriate PT ratio in wired or wireless mode which can directly display the bus voltage After the data is stable pre...

Page 9: ...t Single phase MOA is connected to A yellow channel and the three phases are connected to A yellow B green C red 1 2 There is a fuse on the wire connecting the PT voltage Do not replace it with fuses...

Page 10: ...wiring clips on the yellow and red wires of the current and voltage lines are left open and only the corresponding clips of the green phase B phase are connected 2 3 Phase C measurement The wiring cli...

Page 11: ...terminal of the host D System setting and menu operation method Figure 10 Can clear memory data Adjust the backlight Change time Press the Bluetooth button to pop up the QR code interface use the mob...

Page 12: ...her specifications of fuse or wires instead 9 If the instrument fails it will not damage the tested product It is not allowed to start the repair and disassembly without permission by our company Plea...

Page 13: ...acking list NO Item Qty 1 Low voltage Dedicated test line 1 2 Black test line 1 3 Wireless module 1 4 High voltage Dedicated test line 1 5 Antenna 2 6 Charger 1 7 Ground cable 1 8 Print paper 1 9 Fuse...

Reviews: