background image

1

I. Introduction

The DC resistance is the transformer’s semi-finished product, finished product test,

installation, commissioning test, and electric part prevention test necessary test project

the transformer coil can effectively find the device welding, connecting parts loose,

missing unit, disconnection, and other manufacturing default and other hidden danger

occurred after operation.

The DC Resistance transformer to meet fast measurement requirement, we developed

HZ-3140A DC Resistance Tester. The instrument is a new powerful technology, small size,

light weight, high output current and other characteristics.

The device is controlled by the microcontroller, with a high degree of automation,

automatic discharge functions. It is a test instrument of high precision, simple, direct way

to achieve fast transformer measurement.

II. Safety Measure

1. Before using this equipment you must carefully read the manual.

2. The equipment operator should have electric general knowledge.

3. Avoid putting the equipment in the contact of the rain, corrosive gas, dust, high

temperature, direct sunlight, and other places.

4. Severe vibration has to be avoiding for gauges.

5. Only an expert must maintain and adjust the equipment.

6. After the test, the user must wait till the discharge alarm stopped before switching off

the device, and plugging off the test cables.

7. To measure no-load regulating transformers, the user has to wait till the discharge

instructions alarm stops before switching stalls.

8. During testing, do not move the testing clamp and cables.

III. Configuration

1. Whole instrument controlled by high speed SCM, high automatic degree and simple

operation.

Summary of Contents for HZ-3140A

Page 1: ...HZ 3140A Transformer DC Resistance Tester Huazheng Electric Manufacturing Baoding Co Ltd...

Page 2: ...ual and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this ins...

Page 3: ...s I Introduction 1 II Safety Measure 1 III Configuration 1 IV Technical Data 2 V Presentation Of The System 3 VI Test And Operating 3 VII Caution 7 VIII Guarantee and After Sales Service 7 IX Packing...

Page 4: ...s It is a test instrument of high precision simple direct way to achieve fast transformer measurement II Safety Measure 1 Before using this equipment you must carefully read the manual 2 The equipment...

Page 5: ...agement technology instrument is always working at minimum power state effective energy saving reduce heat 7 320 x240 matrix of ultra small pixel 65K true color LCD 8 With calendar clock and power sto...

Page 6: ...selecting the current The microcomputer control to realize all testing process I I Current output terminals I is the positive current I is the negative current V V Voltage input terminals V is the pos...

Page 7: ...A B C I I Testing product Measurement device O V V a b c B magnetic assisted connections see picture 3 to 5 suitable Y N d 11junction group A B C I I Measurement device O V V a b c Testing product Pic...

Page 8: ...device O V V a b c Testing product A B C I I Measurement device O V V a b c Testing product Picture 3 4 5 respectively measure low voltage Rac Rba Rcb connection 2 Instrument boot up page is as follow...

Page 9: ...menu at the boot state then press select key enter to the data query press select or start up key to turn pages querying 4 After selecting the current press START UP to start the test When press START...

Page 10: ...ll display CURRENT VERY LOW when the two status appear to confirm the range and select the suitable current and carry testing 4 After the test press RESET and winding device will disconnect the power...

Page 11: ...IX Packing List No Item Qty 1 Main engine 1 2 Red test line 1 3 Black test line 1 4 Power line 1 5 Ground lead 1 6 Fuse pipe 2 7 Print paper 1 8 Test sample Standard resistance 1 9 Serial port line 1...